Theory of Operation Ver. 1.0 Apr. 2005
6.2
Print Start Sequence
6.2.1
When the pre-start control is not provided
Start key
ON
Polygon
Motor
Main
Motor
Paper Take-Up
Solenoid
/S1
Drum Charge
Output
Exposure
Output
Developing
Output
Image
Transfer
Output
Drum charge DC
Charge
Reverse bias
Negative output
6. Operating Sequence
Drum charge DC
Charge
Reverse bias
Negative output
ON
Unexposed area
output
4980M013AA
17