Technical Data; Dimensions And Weights, Degree Of Protection; Noise Level; Temperature/Atmospheric Pressure Limits - Bosch BEA 460 Product Description

Bosch-emissions-analyzer
Hide thumbs Also See for BEA 460:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 18
en
32 | BEA 460 | Technical data
6.

Technical data

6.1
Dimensions and weights, degree of
protection
Function
Dimensions H x W x D:
Weight
Degree of protection
6.2

Noise level

Emission sound pressure level as per EN ISO 11200 in
diagnosis mode:
Normal operation
6.3
Temperature/atmospheric pressure
limits
Designation
Operating temperature
Storage temperature
Atmospheric pressure
Maximum load capacity of Viton hose of sampling probe:
Max. temperature
1 680 790 049
Sustained
200 °C
Peak, max. 3 minutes
250 °C
6.4
AMM measuring ranges, accuracy
and resolution
Component
Min.
CO
0 %vol
CO
0 %vol
2
HC [ppm vol]
0
O
0 %vol
2
Lambda
0.5
CO
0 %vol
(not in
vrai
Germany)
NO [ppm vol]
0
Accuracy class 1 and class 0 as per OIML R99 Ed. 1998.
6.5

DTM plus

Temperature
Min.
Oil temperature sensor
-20 °C
|
|
1 689 989 027
2009-03-26
Specification
approx. 260 x 400 x 410 mm
16 kg
IP 31
LpA = 46 dB(A)
Min.
Max.
5 °C
40 °C
– 25 °C
60 °C
700 hPa
1060 hPa
1 680 790 052
200 °C
500 °C
Max.
Resolution
10.00 %vol
0.001 %vol
18.00 %vol
0.01 %vol
1
9999
22.00 %vol
0.01 %vol
0.001
9.999
0.01
10.00 %vol
5000
1
Max.
Resolution
150 °C
0.16 °C
Speed, gasoline [/min
Min.
]
BDM
600
*)
Clip-on trigger
100
100
TDC / opt. sensor
100
Primary connecting cable
(terminal1 / TD/TN / EST)
Speed, diesel [/min
Min.
]
BDM
600
*)
Clip-on sensor
250
TDC sensor
100
100
Primary connecting
cable (TD/TN signal)
Operating voltage range with battery ripple 9 – 32 V
*)
Ignition point/timing
Min.
[°crank angle]
TDC reference mark
-179
sensor with respect
to clip-on trigger
(at 100 - 8000 min
)
-1
0
Timing light with
clip-on trigger
Dwell angle
Min.
Terminal 1
0
Terminal 1
0
Terminal 1
0
Terminal 1
50.0
Start of delivery / timing
Min.
[°crank angle]
-179
Clip-on sensor with
respect to TDC/
timing light
Multiple measurements
Lambda sensor voltage
6.6

Bluetooth Class 1

Radio link
BEA 460 to PC/Laptop
Free field workshop environment
In passenger compartment,
with vehicle door or window
open and engine running
6.7

MID Environmental classes

Class
Mechanical
Electromagnetic
Max.
Resolution
6000
10
15000
10
8000
10
15000
10
Max.
Resolution
6000
10
7200
10
7200
10
7200
10
Max.
Resolution
180
0.1
60
0.1
Max.
Resolution
100 %
0.1 %
360 °VW
0.1 °
50 ms
0.01 ms
99.9 ms
0.1 ms
Max.
Resolution
180
0.1 °crank
angle
Tolerance
Resolution
±5 V
10 mV
Minimum range
30 meters
10 meters
Level
M1
E2
Robert Bosch GmbH

Advertisement

Table of Contents
loading

Table of Contents