4.3a PACKING OF LIFEJACKET WITH HALKEY ROBERTS
INFLATOR
1. Place the lifejacket on a table.
Close the CO
-cylinder cover and wrap the
2
elastic band around it.
2. Fold up the bottom section on the right hand
side of the buoyancy chamber.
3. Fold the left section towards the middle.
4. Fold the right section like a fan with the inflator
on top.
5. Close the cover on the right hand side.
IMPORTANT: The release line must protrude
from the cover.
6. Fold up the bottom section on the left hand side.
7. Fold the right section towards the middle.
8. Fold the left section towards the middle with the
inflator on top.
9. Close the cover on the left hand side.
IMPORTANT: The release line must protrude
from the cover.
10. Fold the neck like a fan with the welding visible.
11. Close the cover in the middle of the top.
12. Fold in the corners. The welding must be visible.
13. Close the cover completely.
4.3a PACKING OF LIFEJACKET WITH HAMMER INFLATOR
1. Place the lifejacket on a table.
2. Fold up the bottom section on the right hand
side of the buoyancy chamber.
3. Fold the right section of the buoyancy chamber
under the inflator.
4. Fold the left section towards the middle, the
inflator must be visible.
5. Close the cover on the right hand side.
IMPORTANT: The release line must protrude
from the cover.
6. Fold up the bottom section on the left hand side.
7. Fold the right section towards the middle.
8. Fold the left section towards the middle.
9
Close the cover on the left hand side.
IMPORTANT: The release line must protrude
from the cover.
10. Fold the neck like a fan with the welding visible.
11. Close the cover in the middle of the top.
12. Fold in the corners. The welding must be visible.
13. Close the cover completely.
4.4a REPLACEMENT OF CO
(HALKEY ROBERTS INFLATOR)
After use in fresh water dry the lifejacket. If the
lifejacket has been used in salt water, it must be
rinsed with fresh water before drying. Deflate the
lifejacket using the oral inflation valve.
1. Unscrew the automatic holder (8) and dispose
the bobbin (7). Carefully rinse the holder in fresh
water and dry it.
2. Unscrew the used CO
3. Place a new bobbin (7) in the inflator. Screw the
automatic holder onto the inflator.
VIKING SOLAS Lifejacket Child – Automatic 90N
-CYLINDER AND BOBBIN
2
-cylinder and dispose it.
2
4. The green indicator (9) must be visible inside the
automatic holders.
5. If the release arm (3) has been pulled out, press
it back into position and place the indicator clip
(4) over the release arm.
6. Gasket (2) under the CO
removed and disposed. Insert a new gasket
in the inflator (5). Place it at the bottom right of
the inflator.
7. Screw the CO
-cylinder (1) into the inflator and
2
manually tighten.
4.4b REPLACEMENT OF CO
TIC INFLATOR
Please see enclosed instructions from Hammar.
5.
SPARE PARTS
Halkey Roberts inflator:
The bobbin, CO
-cylinder and indicator clip come in
2
sets. Do not open until required for use.
It is recommended to keep a spare set.
Complet set, item no.:
Indicator clips, item no.:
CO
-cylinder, item no.:
2
Hammar inflator:
CO
-cylinder and spare parts for inflator, delivered
2
separately. Do not open until required for use.
It is recommended always to keep a spare set.
The above set has item No.:
Light:
Light, item no.:
6.
STORAGE
The lifejacket should be stored in a dry place, possibly
suspended on a hanger in a closet. Unintended inflation
may occur due to a combination of moisture and
vibration. Annual service can reduce the risk of
unintended inflation.
7.
APPLICATIONS AND LIMITATIONS
The lifejacket has been tested in water temperatures
ranging from 0°C to -30°C. At water temperatures below
zero, automatic inflation may be delayed. If so, release
it manually.
Do not ever wear any clothing over VIKING SOLAS 90N.
If worn together with an immersion suit or any special
clothing such as sailors' wear with buoyancy, the
functioning of the lifejacket may be affected.
Please note that a lifejacket fitted with Hammar inflators
only inflates automatically when immersed into water
deeper than 10 cm.
-cylinder must be
2
CYLINDER AND HYDROSTA-
2
1037918
1013530
1037351
1037916
1040395 / 1040396