P/N 550005663 - is used on all Air Defrost model evaporators and features a built in Air Defrost time clock. The default defrost
settings are every 6 hours for 30 minutes. See pages 20-21 for default and custom defrost setting instructions.
P/N 550005664 - is used on all Electric defrost model evaporators. See page 22 for Electric Defrost Timer setting instructions.
NOTE:
The 550005664 display will be blank during the electric defrost cycle.
Access Setpoint mode by pressing and holding the
ts (Temperature setpoint) displays on the screen
Use the
up and
Press
to view the current setting
Use the
up and
Press and hold the
Press the

Setpoints

tS = Temperature setpoint
diF = Differential
CSH = Maximum compressor starts/stops
dPd = Defrost per day
tod = time of day ( only used when custom defrost is selected)
dFt = Defrost time
HAO = High Alarm Offset
down arrows to scroll through the available setpoints
down arrows to change the setpoint
button to confirm each setpoint change