Table 10—Orifice Size* And Manifold Pressure For Gas Input Rate (Continued)
(Tabulated Data Based On 22,000 Btuh Per Burner, Derated 4 Percent For Each 1000 Ft Above Sea Level)
AVG GAS
ALTITUDE
HEAT VALUE
RANGE
AT ALTITUDE
(FT)
(BTU/CU FT)
600
625
9001
650
to
675
10,000
700
725
* Orifice numbers 43 are factory installed
SPECIFIC GRAVITY OF NATURAL GAS
0.58
Orifice
Manifold
Orifice
No.
Pressure
No.
43
2.7
43
43
2.5
43
43
2.3
43
43
2.1
43
48
3.7
43
48
3.5
48
38
0.60
0.62
Manifold
Orifice
Pressure
No.
Pressure
2.8
43
2.6
43
2.4
43
2.2
43
2.0
43
3.6
48
0.64
Manifold
Orifice
Manifold
No.
Pressure
2.9
43
3.0
2.6
43
2.7
2.4
43
2.5
2.3
43
2.3
2.1
43
2.2
3.7
43
2.0