WARNING: If the information in this manual
is not followed exactly, a fire or explosion may
result causing property damage, personal injury
or loss of life.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
— WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call the
fire department.
— Installation and service must be performed by a
qualified installer, service agency or the gas
supplier.
Do not use this furnace if any part has been under
water. Immediately call a qualified service techni-
cian to inspect the furnace and to replace any part
of the control system and gas control which has
been under water.
USER'S INFORMATION MANUAL
USER'S INFORMATION MANUAL
NOTE TO INSTALLER:
equipment user.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 311AAV and is the answer not in the manual?

Questions and answers

Summary of Contents for Bryant 311AAV

  • Page 1 USER’S INFORMATION MANUAL USER’S INFORMATION MANUAL MODEL 311AAV and 312AAV DOWNFLOW/HORIZONTAL/ UPFLOW GAS FURNACE NOTE TO INSTALLER: This manual must be left with the equipment user. WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 2: Welcome To Today'sgeneration Of Comfort

    Years went into the development of your new furnace. Take a little time now to assure its most efficient operation for years to come. MODEL 311AAV and 312AAV (Furnace shown in upflow position; may be used in downflow or horizontal positions also)
  • Page 3: Important Facts

    IMPORTANT FACTS NOTE: The qualified installer or burners with a match or other source of agency must use only factory- flame. Your furnace must have adequate air- authorized re-placement parts, kits, flow for efficient combustion and safe and accessories when modifying or ventilation.
  • Page 4: Steps For Starting Your Furnace

    STEPS FOR STARTING switch to turn off and on. Turn the control switch on the gas valve to YOUR FURNACE the OFF position and wait 5 min- 1. Set your room thermostat to the utes. (See Fig. 9.) lowest temperature setting. (See 6.
  • Page 5: Shutting Down Your Furnace

    lockout. If lockout occurs, or the which can easily be accomplished by blower doesn’t come on—shut down someone who follows the directions, is your furnace and call your dealer for found on this and the following pages. ® service. However, before beginning mainte- nance, follow these safety precautions: 12.
  • Page 6: Combustion Area And Vent System

    COMBUSTION AREA 2. Remove filter cabinet door (See 5. Start the furnace and observe its Fig. 18 and 19.) operation. If possible, watch the AND VENT SYSTEM NOTE: It will be necessary to re- burner flames. Are they burning Inspect the combustion area and vent move 1 thumbscrew bright blue? If not (or if you suspect system before each heating season.
  • Page 7: Regular Dealer Maintenance

    isn’t the cause, call your servicing REGULAR DEALER dealer. MAINTENANCE If your furnace isn’t operating at all, In addition to the type of routine main- check the following list for easily tenance you might be willing to do, solved problems: your furnace should be inspected •...
  • Page 8: Installation Data