8 4 Technical data of controller
Table 3: Technical data of PSk2 controller
Model
Solar input power
[kWp]
PS7k2
7
PS9k2
9
PS15k2
15
PS21k2
21
PS25k2
25
PS40k2
40
8 5 System layout
Smart PSU
3-phase automatic
circuit breaker
BERNT LORENTZ GmbH & Co. KG Kroegerskoppel 7, 24558 Henstedt-Ulzburg, Germany, Tel. +49 (0) 4193 7548 - 0, Fax - 29, www.lorentz.de
All specifi cations and information are given with good intent, errors are possible and products may be subject to change without notice. Pictures may
differ from actual products depending on local market requirements and regulations.
Pump motor:
Pump motor:
rated power
rated voltage
[kW]
[V]
5.5
380 – 400
7.5
380 – 400
11.0
380 – 400
15.0
380 – 400
18.5
380 – 400
30
380 – 400
PV generator
PV combiner
low water sensor
or fl oat switch
nonreturn valve
fi lter cage
Max DC input
MPP voltage
voltage
[V]
[V]
850
500 – 600
850
500 – 600
850
500 – 600
850
500 – 600
850
500 – 600
850
500 – 600
PV module
PV disconnect
for Sun Switch
grounding rod
surge proteector
8
Output current
[A]
13
18
24
30
39
65
PSk2 controller
pressure sensor
surface pump
water sensor
strainer
valve
Sun. Water.
Output frequency
[Hz]
0 – 60
0 – 60
0 – 60
0 – 60
0 – 60
0 – 60
fl oat switch
water meter
valve
fi ller
Figure 1: System layout
Life.