Introduction; Declaration Of Conformity; Psk2 Setup With Pumpscanner - Lorentz PSk2 CS-F Series Manual For Installation, Operation, Service

Solar surface pump systems
Table of Contents

Advertisement

2 Introduction

Thank you for purchasing a LORENTZ pump system
Before you begin – All pump systems are equipped with
nameplates which contain all important data. Check the
model numbers of all the components of your system to
verify that they are items that you ordered and ensure that
the packaging is undamaged and complete.
Check against the pump specifications to be sure the
system is appropriate for your application.
Please fill in the SYSTEM REPORT!
This will be essential information if any problems occur.

3 Declaration of Conformity

We, BERNT LORENTZ GmbH & Co. KG Germany, declare
under our sole responsibility that the products
PSk2 CS-F Series
PSk2 CS-G Series
to which the declaration relates, are in conformity with the
Council Directives on the approximation of the laws of the
EC Member States relating to:
ƒ Machinery (2006/42/EC)
ƒ Electromagnetic compatibility (2004/108/EC)
ƒ Electrical equipment designed for use with certain
voltage limits (2006/95/EC)
Henstedt-Ulzburg, Germany
1 January 2013
Bernt Lorentz, CEO
BERNT LORENTZ GmbH & Co. KG Kroegerskoppel 7, 24558 Henstedt-Ulzburg, Germany, Tel. +49 (0) 4193 7548 - 0, Fax - 29, www.lorentz.de
All specifi cations and information are given with good intent, errors are possible and products may be subject to change without notice. Pictures may
differ from actual products depending on local market requirements and regulations.

4 PSk2 Setup with PumpScanner

PumpScanner for Android® is an important tool for
correct PSk2 controller setup Setting up the pump
and mandatory accessories, e g the SunSwitch, is
required for full performance and to not void the
warranty
The PSk2 controller is a new generation solar pump
controller for LORENTZ PSk submersible and PSk surface
pumps. It utilizes a wireless Bluetooth
®
nect to an Android
-based smartphone or tablet running
®
the LORENTZ PumpScanner software.
PumpScanner is available through our partner extranet
website "partnerNET". The PumpScanner software makes
configuration quick and simple.
Every PSk2 controller is shipped with the same default
setup and must be configured by the installer using
PumpScanner.
PumpScanner holds the latest
versions of pump system firmware
as well as new features We highly
recommend you update PumpScan-
ner prior to each system install to
ensure you have the latest version
There is a logical process to follow when installing
PSk2 systems:
1.
Make sure the latest version of PumpScanner is
installed on your Android device
2.
Make sure you have registered the PSk2 system on
Sites in partnerNET and updated your license list in
PumpScanner
3.
Complete the physical installation as per the PSk2
manual
4.
Connect power but do not start the pump (toggle
switch on controller is in position "OFF")
5.
Connect to the pump controller using PumpScanner
as per the PumpScanner manual
6.
Check the controller Firmware version as per the
PumpScanner manual and update it if asked to do so
by PumpScanner
7.
Configure the pump controller using PumpScanner as
per the PSk2 manual and PumpScanner manual
8.
Switch on the controller
9.
Optional: Install the PS Communicator as per the PS
Communicator manual
4
PSk2 configuration – PSk2 simplifies the installation
process by using our PumpScanner Android
program the parameters of the controller. This programing
is very simple and only requires the correct controller and
pump to be selected as well as the setup of parameters
according to the COMPASS report. The PSk2 incorporates
the PS DataModule that stores running data and allows
programming of additional features. Using PumpScanner
connection to con-
you can look at the real-time and historic performance of
the pump.
PumpScanner – You will need to install PumpScanner on
an Android
device (smartphone or tablet). No SIM card or
®
contract is required, the communication is via Bluetooth
You can download and license PumpScanner here:
http://www lorentz de/pumpscannerapp
or use the following QR code:
Read the PumpScanner manual to understand how to link
the controller to your Android device.
DataModule Registration – To set up a pump using
PumpScanner, access to the DataModule is necessary. To
gain access, the pump system with DataModule must be
registered at LORENTZ partnerNET "Sites". After registering
at "Sites", the "Licence List" must be updated within
PumpScanner settings. For detailed information refer to
partnerNET. You can register your pump system here:
App to
®
http://www lorentz de/sites
Sun. Water.
Life.
.
®

Advertisement

Table of Contents
loading

This manual is also suitable for:

Psk2 cs-g series

Table of Contents