CHECKING BY THE FLUID LEVEL LINES
(MAINTENANCE TYPE BATTERY ONLY)
The fluid (electrolyte) level must be be-
tween the upper and lower lines.
When checking the fluid level, look at all
six cells, not just one or two.
If the level is lower than the lower line,
add distilled water. (See " ADDING DIS-
TILLED WATER".)
WWW.MANUALS.WS
Type A
Clear
or light yellow
Green
Dark
Type B
Blue
White
Red
CHECKING
BY
THE
HYDROMETER
(NON- MAINTENANCE BATTERY ONLY)
Check
the battery condition by
hydrometer color.
Hydrometer color
Condition
Condition
Type A
Type B
GREEN
BLUE
Good
Charging necessary. Have
DARK
WHITE
battery checked by your
Toyota dealer.
CLEAR or
Have battery checked by
LIGHT
RED
your Toyota dealer.
YELLOW
'98 TERCEL (U)
Low
ADDING
DISTILLED
(MAINTENANCE TYPE BATTERY ONLY)
the
1. Remove the vent plugs.
2. Add distilled water to cells needing
fluid.
If the side of your battery is covered,
check the water level by looking down
directly
above
the
cell
above.
3. Retighten the vent plugs securely.
O.K
WATER
as
illustrated