4

Appliance Preparation

A. Securing and Leveling Appliance
CAUTION! Risk of cuts, abrasions or flying
debris. Wear protective gloves and safety glasses
during installation. Sheet metal edges are sharp.
Position, level and secure the appliance.
Place the appliance into position on either
a wood or noncombustible continuous flat
surface.
Level the appliance from side to side and front
to back.
Shim the appliance with noncombustible
material, such as sheet metal, as necessary.
Chase platforms, including hearths, should
slope away from the structure at 1/8 inch to
1/4 inch per foot.
Nailing tabs must be moved from shipping
position to installation position and secured
to framing. Bend the four nailing tabs out on
each side. See Figure 4.1.
B. Flashing
Flash the appliance in a manner consistent
with regional practices to prevent water
penetration around the appliance. Due to
elevated temperatures across the top of the
appliance, metal flashing and high temperature
sealant must be used. Adhesive polymers
flashing materials may melt.
For
brick,
stone,
construction, weep screeds should be installed
per regional codes.
See Section 3.F. and Figures 3.2. for more
information regarding wall and enclosure
construction required to prevent moisture
penetration into the structure. The appliance
will shed moderate amounts of water but is not
waterproof.
Outdoor Lifestyles by Hearth & Home Technologies Inc. • Lanai 48 See Thru Installation Manual • 4113-901 Rev. D • 8/21
stucco
and
similar
NOTE: Use high temp silicone or sealant
recommended by the manufacturer of the house
wrap to seal between combustible sheathing
house wrap and non-combustible sheathing. The
sealant material used within 6 inches of the top
and 1 inch on the sides of the appliance surround
must be approved to withstand a minimum
temperature of 225°F continuous exposure.
House wrap tape with a 225°F minimum
temperature may also be used. See Figure 4.2.
Nailing Flanges
(both sides)
Figure 4.1. Positioning and Securing Nailing Tab
Membrane Overlap
Dotted Lines
Figure 4.2. Membrane Overlap
1 in.
6 in.