Download Print this page

Cleveland 21-CET-16 Specifications page 2

Counter type design pressureless convection steamer electric steam generator, 16 kw
Hide thumbs Also See for 21-CET-16:

Advertisement

ELECTRIC
Volts Watts Ph Amps Wire
Cold water:
35 psi minimum
208
16,300
3
45.9
3
60 psi maximum
220
13,694
3
36.5
3
240
16,300
3
39.8
3
Two
C1 one for Condenser
440
13,694
3
18.2
3
C2 one for Steam Generator
480
16,300
3
19.9
3
360
14,621
3
23.8
4
Unit comes with a
380
16,300
3
25.1
4
40 Mesh Water Strainer
415
16,300
3
23.0
4
(installation required)
NOTES:
Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are UL, ULC, UL/NSF#4, CE and CSA.
WATER
DRAINAGE
C
1
1
˝ N.P.T. tube
4
Do not connect other units
to this drain.
1
˝ NPT Tubing:
4
Drain line must be vented.
No PVC pipe for drain.
Compartment has capacity for:
Five, 12˝ x 20˝ x 2
WATER QUALITY REQUIREMENT
The recommended minimum water quality standards
whether untreated or pre-treated, based upon 10 hours
of use per day, and a Daily Blowdown, are as follows:
TOTAL DISSOLVED SOLIDS less than 60 parts per million
TOTAL ALKALINITY
SILICA
pH FACTOR
CHLORINE
Consult a local water treatment specialist for an on site
water analysis for recommendations concerning steam
generator feed water treatment (if required), in order to
remove or reduce harmful concentrations of minerals.
The use of highly mineralized water will mean that
more frequent servicing of the steam generator will be
necessary. The fact that a water supply is potable is
not proof that it will be suitable for the generator.
CLEARANCE
D
Right - 3", Left - 3", Rear - 3"
(12" on control side if adjoining
wall or equipment is over 30"
high for service access)
Contact factory for
variances to clearances.
1
˝ deep Cafeteria Pans.
2
less than 20 parts per million
less than 13 parts per million
greater than 7.5
less than 30 parts per million
(NOT TO SCALE)
IV
SECT.
Litho in U.S.A.
6
PAGE
0707

Advertisement

loading

This manual is also suitable for:

Steamcraft ultra 5 21-cet-16