- Operating instructions governor Pressure relief valve - Operating instructions Circuit Diagram - EcoPUC MC Hotline and Contact If you have queries or would like technical informa- tion, please contact your dealer or sales partner. 05/2017 EcoPUC MC - MCU00003EN 3/68...
Product overview Product overview Short description The EcoPUC MC (hereafter called “Control Overview system") is a control system with control compo- Main cabinet nents for electrical pumps. Pumping pressure and speed of the electric pumps are regulated via the control system.
Fig. 3: Danger due to electrical voltage Do not exceed the maximum hose lengths and cable lengths Ä 11.2 “Connections”. 1 Feed X01 Do not place any objects near the control system. This is valid for electrostatically charge- able objects. 05/2017 EcoPUC MC - MCU00003EN 7/68...
Relieve the pressure on material lines. Guidelines and Rules of engineering Secure against reconnection. Applicable accident prevention regulations The mechanic is responsible for the following activ- ities on equipment and components: Assembly Commissioning Servicing Maintenance Disassemble 8/68 EcoPUC MC - MCU00003EN 05/2017...
Wear the required personal protective equipment when working. Provide the following personal pro- tective equipment: Eye protection Protects eyes from dust, paint drops and particles. Protective gloves Protect the hands from: mechanical forces Thermal forces Chemical effects 05/2017 EcoPUC MC - MCU00003EN 9/68...
Page 10
1 Holes for wall mounting 1 Electrical components 2 Duct for hoses and cables 2 Fan cover with fan 3 Connection for base 3 Controls 4 Duct for hoses and cables 5 Electro-pneumatic components 6 Connection for base 10/68 EcoPUC MC - MCU00003EN 05/2017...
User management User levels control the access to individual functions in the visualizer. Higher user levels have the authorization for lower user levels. – Enter new passwords at the time of commissioning. 12/68 EcoPUC MC - MCU00003EN 05/2017...
Do not store outdoors. tact” Store in a dry and dust-free place. Do not expose to aggressive media. Protect from solar radiation. Avoid mechanical vibrations. Temperature: 10°C to 40 °C Relative humidity: 20% to 80 % 05/2017 EcoPUC MC - MCU00003EN 13/68...
– Do not enter the area below hovering loads. – Wear specified protective equipment. – Only use approved hoists and stoppers. – Ensure that the hoists and stoppers have adequate bearing capacity. 14/68 EcoPUC MC - MCU00003EN 05/2017...
Have two persons to assemble the cabinet. Use anchor bolts M 8. 2. Align cabinet horizontally on the base. Ensure that the cabinet is seated firmly. Follow the circuit diagram Ä “Applicable docu- ments”. Fig. 13: Main cabinet rear side 05/2017 EcoPUC MC - MCU00003EN 15/68...
Follow the circuit diagram Ä “Applicable documents”. Fig. 15: Grounding bolt in the control system housing 1. Connect flexible grounding leads to the grounding bolts (1) in the control system housing. ð The control system is grounded. 16/68 EcoPUC MC - MCU00003EN 05/2017...
– Before carrying out any work: Protective workwear Depressurize hoses. Protective gloves Safety boots 1. Pre-assemble connection line. 2. Connect control system, see circuit diagram “Connection for feed and external” Ä “Appli- cable documents” 05/2017 EcoPUC MC - MCU00003EN 17/68...
Operating conditions correspond to the specifi- – Check hoses for damage. cations Ä 11.3 “Operating conditions”. – Before carrying out any work: Performance values correspond to the specifi- Depressurize hoses. cations Ä 11.4 “Operating values”. 18/68 EcoPUC MC - MCU00003EN 05/2017...
Protective workwear Error messages are acknowledged. Safety boots Fig. 17: Switching on control system Fig. 19: Switch off control system. 3. Press [On] (1). 1. Press [Off] (1). ð The control system is switched off. 05/2017 EcoPUC MC - MCU00003EN 19/68...
ð Configuration is confirmed. 4. Tap button (3). ð The “External” operating mode is switched on. The button has a green border. Fig. 22: Active mode The active operating mode (1) is displayed in the header row. 20/68 EcoPUC MC - MCU00003EN 05/2017...
3. Exit the window using the button (3). Fig. 24: Operator interface 1 Header row 2 Work area 3 Menu bar Header row Fig. 25: Header row 1 Active mode 2 User level 3 Pumps 1 to 4 05/2017 EcoPUC MC - MCU00003EN 21/68...
Page 22
In the Stand-By mode, the pump is volume-driven. The pump is operated at constant rotational speed. The Production mode, the pump is pressure- driven. A set pressure is entered in the visualizer, which the pump keeps constant by adjusting the speed. 22/68 EcoPUC MC - MCU00003EN 05/2017...
5 Display of the IP address Confirm entry. 6 Display of the software version 7 Cleaning the screen 8 User-dependent buttons Cancel entry and exit window. 9 Set language Button is only displayed if the values entered are correct. 05/2017 EcoPUC MC - MCU00003EN 23/68...
2. Tap field (1). 3. Enter administrator password. 4. Tap button (2). ð The passwords are reset to factory settings. 5. Exit the window again using the button (3). 8.5.3 Change password Personnel: System operator 24/68 EcoPUC MC - MCU00003EN 05/2017...
Measured values are recorded in a CSV file over a period of a week. Alarm data The inputs of the alarm history are recorded in a TXT file. Maximum 500 entries are stored. Personnel: System operator 05/2017 EcoPUC MC - MCU00003EN 25/68...
Ä 8.2 “Header row”. 8.5.7 Setting Date and Clock Time Personnel: Fig. 42: Enable UDP interface System operator 1. Tap button (1). ð Window (2) is opened. 26/68 EcoPUC MC - MCU00003EN 05/2017...
Page 27
11. Keep the button (1) on Touch display pressed for five seconds. ð Menu of the Touch Display is opened. Fig. 45: UDP interface 8. Open IP settings (1). ð “IP settings” window is opened. 05/2017 EcoPUC MC - MCU00003EN 27/68...
15. Enter the same IP Address (2) as entered in 1 m_relStOn: Global switching on approval from step 9. external control system to EcoPUC MC (no fault etc.) 2 m_StOn: Feedback switch-on approval from EcoPUC MC to external control system 3 m_StExtMode: EcoPUC MC in “External"...
Page 29
3 m_ModeP1: Enable production mode from external control system to EcoPUC MC for 1 m_RelStOnP1: Enable local switch-on release pump 1 from external control system to EcoPUC MC for 4 m_AckIntModeP1: Interval mode only possible pump 1 in standby mode.
4 Flow rate in l/min (calculated from the motor fre- 8.5.10 Set language quency) 5 Button “Ext. Mode” Personnel: 6 “Filter maintenance” button System operator 7 “Production/ Standby” button 8 “Start/ Stop” button Fig. 57: Set language 30/68 EcoPUC MC - MCU00003EN 05/2017...
Page 31
“Manual” or “External” operating mode is ena- bled. Pump is in Stand-by mode. No fault is present. “Pump settings” menu is opened Fig. 58. 1. Tap “Filter maintenance” button. ð “Parameter” window is opened. Fig. 59: Parameter input 05/2017 EcoPUC MC - MCU00003EN 31/68...
Production mode. Values between 10 and 50 Hz can be parameterized. Control pressure recirculation controller Parameter for setting the control pressure for the recirculation controller in Production mode. Values between 0 and 5 bar can be parameterized. 32/68 EcoPUC MC - MCU00003EN 05/2017...
2. Switch to “Standby” menu using the button Fig. 61: Setting parameters Fig. 62: Standby 3. Tap the field (1) behind the required parameter. 1 Setting the process parameter(s) 2 Display of the current process values 4. Enter and confirm parameter. 05/2017 EcoPUC MC - MCU00003EN 33/68...
Pressure control lower pressure threshold [bar] ð The time range of the display is 30 min. A warning appears if the bottom pressure threshold is reached. Values between 0 and 17 bar can be parameterized. 34/68 EcoPUC MC - MCU00003EN 05/2017...
Alarm history is limited. Alarm messages are limited to 500 entries. – Old alarm messages are overwritten. Colors of messages Faults are highlighted in red. Warnings are highlighted in yellow. Notes are highlighted in white. 05/2017 EcoPUC MC - MCU00003EN 35/68...
Alarms Drive 4 Alarms B&R Converter P84 Emergency Stop pump 4 Local Emergency Stop pump 4 Buzzing alarm process pump 4 Local process alarms pump 4 Buzzer warnings pump 4 Local warnings Pump 4 36/68 EcoPUC MC - MCU00003EN 05/2017...
Page 37
3 Powerlink connection Drive 4 Error in the power link connection to the frequency converter of the pump 4 FREE FREE General Error UDP connection No communication of the UDP interface with external control 05/2017 EcoPUC MC - MCU00003EN 37/68...
Page 38
Error update set up data Setup data cannot be transferred from USB stick. FREE FREE FREE Error while saving the file Error while saving the data on USB stick FREE FREE FREE FREE FREE FREE FREE FREE FREE 38/68 EcoPUC MC - MCU00003EN 05/2017...
Page 39
Frequency converter [Input phase loss] Loss Power Input Phase - 1 (PHF) Frequency converter [Undervoltage] Low voltage (USF) Frequency converter [Motor short circuit] Motor short circuit (hard detection) (SCF1) Frequency converter [Overspeed] (SOF) Overspeed 05/2017 EcoPUC MC - MCU00003EN 39/68...
Page 40
PTCL-error (OC or SC) (PtFL) Frequency converter [PTC fault] (OtFL) Motor overheating detected by PTCL: Standard product Frequency converter [Internal- I measure] Error in current measurement (InF9) Frequency converter [Internal-mains cir- Network phase loss error cuit] (InFA) 40/68 EcoPUC MC - MCU00003EN 05/2017...
Page 41
FREE Frequency converter [Cards pairing] Error in hardware configuration (HCF) FREE FREE Frequency converter [Load fault] (dLF) Error in dynamic load Frequency converter [Bad conf] (CFI2) Error in configuration transfer FREE FREE FREE FREE 05/2017 EcoPUC MC - MCU00003EN 41/68...
Page 42
FREE Frequency converter [Safety fault] (SAFF) Triggering the safety function Frequency Converter [FB fault] (FbE) Function block Error Frequency converter [FB stop flt.] (FbES) Function Block Schematic FREE FREE FREE FREE FREE FREE FREE 42/68 EcoPUC MC - MCU00003EN 05/2017...
Page 43
FREE FREE Overspeed in Production model (alarm Speed of the pump 1 / 2 / 3 / 4 is super- data) Pump 1 / 2 / 3 / 4 elevated for a set time. 05/2017 EcoPUC MC - MCU00003EN 43/68...
Page 44
Service interval at 23760 operating hours Service interval 6 pump 1 / 2 / 3 / 4 due: Service interval at 39600 operating hours Cleaning/ changing air filter EcoPUC MC Service interval at 2000 operating hours M / E1 / E2 / E3...
– Wear ear protection. WARNING! Risk of injury from unsuitable replacement parts Parts of third party suppliers may not bear the loads. Serious injuries and death can result. – Only use original replacement parts. 05/2017 EcoPUC MC - MCU00003EN 45/68...
Verified that no current is present. Compressed air supply is switched off. System is depressurized: Close shutoff valve. For hose types, see circuit diagram Ä “Appli- cable documents”. 1. Pull out compressed air hose from the plug con- nection. 46/68 EcoPUC MC - MCU00003EN 05/2017...
– Before carrying out any work, disconnect electrical supply. – Check components in the control system to verify that no current is present. – Only qualified electrical technicians are allowed to work on control system, electrical lines and components. 05/2017 EcoPUC MC - MCU00003EN 47/68...
– Ensure that the hoists and stoppers have adequate bearing capacity. Disassembling main cabinet Personnel: Mechanic Protective equipment: Protective workwear Protective gloves Safety boots 1. Use a suitable hoist to secure main cabinet against toppling. 05/2017 EcoPUC MC - MCU00003EN 49/68...
– In case of doubt, refer to the local disposal Extension cabinet without base 75 kg authorities. Extension cabinet with base 100 kg Personnel: Mechanic Protective equipment: Protective workwear Protective gloves Safety boots 50/68 EcoPUC MC - MCU00003EN 05/2017...
Maximum air pressure Frequency 50 / 60 Hz Protection type Voltage Power Frequency Power Option Value Protection EcoPUC MC-X-0750-XX-X-X-X 2.3 kVA Weight CE labeling EcoPUC MC-X-1500-XX-X-X-X 4.2 kVA Manufacturer EcoPUC MC-X-3000-XX-X-X-X 7.3 kVA QR code 05/2017 EcoPUC MC - MCU00003EN 51/68...
(NC) Proportional valve Detail Value Electrical current strength, min. 4 mA Electrical current strength, max. 20 mA Scaling output pressure, min. 0.15 bar Scaling output pressure, max. 6 bar 52/68 EcoPUC MC - MCU00003EN 05/2017...
Blind plug M 63, gray E14840019 Hose 4 x 6 Blue W40031005 Lock nut M 63, gray E14820019 12.2 Tools Thermostat E44100007 There are no special tools available for this Current monitoring feed E18260002 product. 05/2017 EcoPUC MC - MCU00003EN 53/68...
Serious injuries and death can result. – Only use original replacement parts. Ordering replacement parts, tools and accessories as well as information on products that are listed without order number. Ä “Hotline and Contact” 54/68 EcoPUC MC - MCU00003EN 05/2017...
Switching On Pump 1 (Local)....... 29 Contact..............3 Switching Over Interval Mode Pump 1 (Local)............29 Control system Switching over standby production pump connect to ground......... 16 1 (local)............29 Flow rate............51 Frequency............51 05/2017 EcoPUC MC - MCU00003EN 55/68...
Page 56
Notes............... 6 Operating parameters Residual risks............8 adjustment............ 18 Compressed air..........8 Operation Danger to health from harmful or irritant Safety instructions......... 18 substances............8 Operator interface Electric current..........8 Overview............21 Grounding............8 56/68 EcoPUC MC - MCU00003EN 05/2017...
Page 57
Technical data Interfaces............52 “ Operating conditions........51 “External” operating mode Technical Data Control panel..........20 Connections............ 7 switching off..........20 switch on............20 Tools..............53 UDP interface..........20 Touch display Setting IP address......... 26 05/2017 EcoPUC MC - MCU00003EN 57/68...
Page 68
Dürr Systems AG Application Technology Carl-Benz-Str. 34 74321 Bietigheim-Bissingen www.durr.com Original operation manual Transmission and duplication of this document, as well as use and sharing of its contents are not permitted without express written approval. Violations will be liable for compensation for damages. All rights in the event of a patent grant or design registration are reserved.