Command Functional Groups - Honeywell HPB User Manual

Precision barometer rs-232 and rs-485 output
Hide thumbs Also See for HPB:
Table of Contents

Advertisement

HPB/HPA User Manual
REPEAT THE READ CONTINUOUS PRESSURE STEP ABOVE
Notice the slower output rate of one sample every 2 seconds.
TRY OTHER COMMANDS
Experiment with other commands to become familiar with the command structures. A short overview of
each command with input and response examples is shown in Section 3 Commands – Quick Reference.
See Section 5—Commands for complete command descriptions. Re-apply the power or send an
IN=RESET command to revert to EEPROM default settings. Until an SP=ALL command is executed, no
changes will be stored in the EEPROM.

2.7 COMMAND FUNCTIONAL GROUPS

PRESSURE DISPLAY UNITS —HPB reads out psi, in wc, mm Hg, etc.
DU
U=
TEMPERATURE
T1
T2
T3
T4
RS-232/RS-485 BUS PARAMETERS
BP
ID
M=
SI
TO
OUTPUT READING AND RATE—Speed up or slow down output rate
Single Reading Commands
P1
P3
T1
T3
Continuous Readings Commands
P2
P4
T2
T4
Integration Time Commands —
DS
I=
S2
S5
SI
Idle Count Command —Changes pressure reading response time
IC
Reading Response To Changes In Input Pressure—Filters small changes
S2
S5
RR
OP
10
Set pressure units for output readings—any one of 13 common units (See Section 8)
Specify a user supplied unit of measure
Single °C
Continuous °C
Single °F
Continuous °F
Changes baud rate and parity
Assign device ID and group addresses
Select alternate message Headers [RS-485 only]
Synchronize Integration cycles among units [RS-485 only]
Set Transceiver Operating parameters
Single pressure reading...ASCII format
Single pressure reading...binary format
Single temperature reading...°C
Single temperature reading...°F
Continuous pressure readings...ASCII format
Continuous pressure readings...binary format
Continuous temperature readings...°C
Continuous temperature readings...°F
Changes pressure reading response time
Set deadband and sensitivity parameters
Set pressure integration time, and sampling rate
Set threshold level for 2X speed shift
Set threshold level for output within any 50 msec period
Synchronize pressure Integration cycles
Set number of idle integration cycles
Set threshold level for 2X speed shift
Set threshold level for output within any 50 msec period
Set number of identical readings to skip
Transmit all readings or only changed readings