Pentair PM1700 Series Original Instruction Manual

4/5/6/7/8 roller pumps

Advertisement

Quick Links

SERIES PM4101
4-ROLLER PUMP
Max. Flow Rate: ................ 7 gpm
Max. Pressure: .................150 psi
Max. RPM: ........................... 2600
Ports: ....... 3/4" NPT Inlet & Outlet
Shaft: .................. 5/8" Dia. (Solid)
1/2" Dia. (Hollow)
Continuous Operation .....100 psi
Intermittent Operation .....150 psi
Pentair
375 5th Ave., New Brighton, MN 55112
Phone: (651)766-6300 -OR- 800-424-9776 Fax: 800-323-6496
www.hypropumps.com
EU Authorized Representative:
Distributed by John Deere
Original Instruction Manual
Series PM1700, PM6500, PM7560, PM7700 Roller Pumps
Keep for Future Reference
Max. Flow Rate: ........... 22.8 gpm
Max. Pressure: .................300 psi
Max. RPM: .................... 1200 rpm
Ports: ....... 3/4" NPT Inlet & Outlet
Shaft: .................. 5/8" Dia. (Solid)
Continuous Op. ................100 psi
Intermittent Operation .....300 psi
SERIES PM7700
7-ROLLER PUMP
Max. Flow Rate: ........... 22.1 gpm
Max. Pressure: .................200 psi
Max. RPM: ...................... 800 rpm
Ports: ....... 3/4" NPT Inlet & Outlet
1" Hose Barb Included
Shaft: .............. 15/16" Dia. (Solid)
Continuous Operation .....100 psi
Intermittent Operation .....200 psi
QNET BV Hommerterweg 286
EB
REP
6436 AM Amstenrade, The Netherlands
KvK Zuid-Limburg 14091511
SERIES PM6500
6-ROLLER PUMP
1" Hose Barb Included
SERIES PM1700
Max. Flow Rate: .............. 45 gpm
Max. Pressure: ................ 200 psi
Max. RPM: .................... 1000 rpm
Ports: .......... 1" NPT Inlet & Outlet
Shaft: .............. 15/16" Dia. (Solid)
Continuous Operation .....100 psi
Intermittent Operation .....200 psi
SERIES PM7560
8-ROLLER PUMP
Max. Flow Rate: ........... 22.5 gpm
Max. Pressure: .................300 psi
Max. RPM: .................... 1000 rpm
Ports: ....... 3/4" NPT Inlet & Outlet
Shaft: .............. 15/16" Dia. (Solid)
Continuous Operation .....100 psi
Intermittent Operation .....300 psi
5-ROLLER PUMP
1-1/4" Hose Barb Included
Form
L-0100R-JD
Rev. A
1" Hose Barb Included

Advertisement

Table of Contents
loading

Summary of Contents for Pentair PM1700 Series

  • Page 1 Shaft: ....15/16” Dia. (Solid) Continuous Operation ..100 psi Continuous Operation ..100 psi Intermittent Operation ..200 psi Intermittent Operation ..200 psi Pentair 375 5th Ave., New Brighton, MN 55112 Phone: (651)766-6300 -OR- 800-424-9776 Fax: 800-323-6496 www.hypropumps.com EU Authorized Representative: QNET BV Hommerterweg 286...
  • Page 2: Table Of Contents

    Contents Introduction.................................3 Description..............................3 Intended Uses................................3 Purpose of Manual..............................3 Misuses................................3 Pump Manufacture Date............................4 Pump Technical Data..............................4 Fluid Pumping Application............................9 Tools................................9 Lifting, Transport, and Intermediate Storage......................10 Assembly and Installation..............................11 Assembly............................11 Installation..........................11 Standard Mounting............................11 Control Systems...............................12 Commissioning Start-Up, Operation, Shutdown........................12 Information.............................12 Start-Up, Operation, Shutdown..........................13 Maintenance and Servicing..............................13 Information..........................13 D i s p o s a l .
  • Page 3: Introduction

    Introduction Description Roller pumps are designed for creating and boosting pressure in fluid circuits. The economical rotary-action roller principle requires no check valves, while providing positive displacement characteristics with less friction and lower starting torque than other pumps. The pump operates by receiving a fluid through the inlet port where it is captured and transported by the rollers, and then expelled through the outlet port.
  • Page 4: Pump Manufacture Date

    First and second digits: year (12 = 2012) Third through fifth digits: consecutive day of the year the pump was manufactured. Pump Technical Data (All specifications and performance data are based on water as a carrier fluid) PM1700 Series Pump Only Pump Dimensions Dim.
  • Page 5 PM4101 Series Pump Only Pump Dimensions Dim. Inch 4.75 2.38 1.67 3.03 5.39 3.34 1.00 1.43 2.96 1.75 PM4101C, PM4101XL Pump Specifications Max. Max. Continuous Intermittent Dry Weight Horsepower Mounting Rollers Flow Rate Pressure Ports Shaft Operation Operation (LBS [KG]) requirement bolts (GPM[LPM]) (PSI[Bar]) (PSI[Bar]) (PSI[Bar])
  • Page 6 PM6500 Series Pump Only Pump Dimensions Dim. Inch 6.13 3.07 2.22 4.09 5.41 3.27 2.12 1.06 1.37 3.87 PM6500C, PM6500XL Pump Specifications Max. Max. Continuous Intermittent Dry Weight Horsepower Mounting Rollers Flow Rate Pressure Ports Shaft Operation Operation (LBS [KG]) requirement bolts (GPM[LPM]) (PSI[Bar]) (PSI[Bar]) (PSI[Bar])
  • Page 7 PM7650 Series Pump Only Pump Dimensions Dim. Inch 7.00 3.50 2.88 5.45 6.91 4.37 2.12 1.06 1.97 3.25 PM7560C, PM7560N, PM7560XL Pump Specifications Max. Max. Continuous Intermittent Dry Weight Horsepower Mounting Rollers Flow Rate Pressure Ports Shaft Operation Operation (LBS [KG]) requirement bolts (GPM[LPM]) (PSI[Bar]) (PSI[Bar]) (PSI[Bar])
  • Page 8 PM7700 Series Pump Only Pump Dimensions Dim. Inch 6.75 3.38 2.94 5.48 6.91 4.38 2.12 1.06 1.98 3.81 1.13 PM7560C, PM7560N, PM7560XL Pump Specifications Rollers Max. Max. Ports Shaft Continuous Intermittent Dry Weight Horsepower Mounting Flow Rate Pressure Operation Operation (LBS [KG]) requirement bolts (GPM[LPM]) (PSI[Bar]) (PSI[Bar])
  • Page 9: Fluid Pumping Application

    Fluid Pumping Applications Pump Materials Compatible Application Comments Silver Cast Series Iron Resist Weed Control Use with super rollers and viton seals. When using with Round- Chemicals up use super or polypropylene rollers and Viton seals. Teflon rollers may be used with Roundup up to 100psi. Only Ni-Resist and Silver series pumps should be used with Roundup.
  • Page 10: Lifting, Transport, And Intermediate Storage

    Lifting, Transport, and Intermediate Storage Packaging Descriptions and Unpacking Instructions • Roller pumps are shipped in cardboard boxes for safe transporting. • When pumps are shipped in large quantities they may be put on a pallet to allow for easy storage, lifting and handling. •...
  • Page 11: Assembly And Installation

    Assembly and Installation Assembly This pump comes completely assembled Installation Before attempting to install your Hypro centrifugal pump it is imperative to read and understand the following: • Installation of a pump should only be performed by a technician having the knowledge and skills necessary to install the pump without the risk property damage or injury.
  • Page 12: Control Systems

    Control Systems For more detail on a typical system installation, see preceding subsections of the “Assembly and Installation” section of this manual. Commissioning, Start-Up, Operation, Shutdown Before attempting to start your pump the following must be understood and followed to ensure safe operation. Information •...
  • Page 13: Start-Up, Operation, Shutdown

    Start-up, Operation, Shutdown Before Starting the Pump • Ensure all unnecessary personnel are clear of the area • For initial setup and test of your system, it is recommended to start with clean water instead of chemicals, and confirm the system and plumbing connections are leak free. •...
  • Page 14: C L E A N I N

    Cleaning Your pump will last longer and give best performance when properly taken care of. Proper pump care depends on the liquid being pumped and when the pump will be used again. After each use, flush pump with a neutralizing solution for the liquid just pumped.
  • Page 15: Replacement Parts

    Replacement Parts The following drawings show the pumps and their replacement parts. Only genuine replacement parts should be used, failure to follow this warning can result in damage to property, serious injury or death. If the pump malfunctions or is defective it should be sent back to the manufacturer for service. Series PM1700 IMPORTANT: Ref.
  • Page 16 Series PM4101 Ref. Qty. Part Part IMPORTANT: Req’d. Number Description When ordering parts, give PART NUM BER and PART DE SCRIP TION. PM20000010 Ball Bearing (High temp. grease) Ref er ence Numbers are used ONLY PM21070002 Viton Seal to point out parts in the draw ing and are NOT to be used as or der ing O-Ring Gasket for Endplate numbers.
  • Page 17 Series PM6500 Ref. Qty. Part Part IMPORTANT: Req’d. Number Description When ordering parts, give PART NUM BER and PART DE SCRIP TION. PM20000010 Ball Bearing Ref er ence Numbers are used ONLY PM21070002 Viton Seal to point out parts in the draw ing and are NOT to be used as or der ing O-Ring Gasket for Endplate numbers.
  • Page 18 Series PM7560 IMPORTANT: Ref. Qty. Part Part When ordering parts, give PART Req’d. Number Description NUM BER and PART DE SCRIP TION. Ref er ence Numbers are used ONLY PM20080001 Sealed Ball Bearing to point out parts in the draw ing and PM21120003 Viton Seal are NOT to be used as or der ing...
  • Page 19 Series PM7700 Ref. Qty. Part Part IMPORTANT: When ordering parts, give PART Req’d. Number Description NUM BER and PART DE SCRIP TION. PM20080001 Sealed Ball Bearing Ref er ence Numbers are used ONLY to point out parts in the draw ing and PM21120003 Viton Seal are NOT to be used as or der ing...
  • Page 20: Declaration Of Incorporation

    EC Declaration of Incorporation Manufacturers Name: Pentair Flow Technologies, LLC Manufacturers’ Address: 375 Fifth Avenue NW, New Brighton, MN 55112, USA Declare that the partially complete machinery described below conforms to applicable health and safety requirements of Parts 1 of Annex I of Machinery Directive 2006/42/EC. This partly completed machinery must not be put into service until the equipment into which it is to be incorporated has been declared in conformity with the provisions of this directive.
  • Page 21: Warranty

    Returns are to be shipped with the RMA number clearly marked on the outside of the package. Hypro shall not be liable for freight damage incurred during shipping. Please package all returns carefully. All products returned for warranty work should be sent shipping charges prepaid to: HYPRO / PENTAIR Attention: Service Department 375 Fifth Avenue NW...

This manual is also suitable for:

Pm6500 seriesPm7560 seriesPm7700 series

Table of Contents