Blade Check
Check for worn or damaged trowel blades (Figure 20).
Check to see if one blade is worn out while the others look
new. If this is the case there could be a blade pitch problem.
Refer to the maintenance section of this manual for blade
pitch adjustment procedure. Replace any worn blades.
WORN
Figure 20. Trowel Blade Inspection
WARNING
NEVER disable or disconnect the centrifugal safety
"stop" switch. It is provided for operator safety. Injury
may result if it is disabled, disconnected or improperly
maintained.
Centrifugal Safety "STOP" Switch
This trowel has been equipped with a centrifugal safety
"stop" switch (Figure 21). This switch should be tested
every time the engine is started.
The switching mechanism of this switch should operate
freely and should always be kept in this condition. With the
switch in the OFF position, the engine should not start or
run. The purpose of this switch is to stop the engine in a
runaway situation, (i.e. the operator releasing the handle
during operation).
PAGE 26 — J36/B46-M30 SERIES WALK-BEHIND TROWELS • OPERATION MANUAL — REV. #0 (10/27/16)
*Always follow manufacturer instructions*
WORN
Operation
This section is intended to assist the operator with the initial
start-up of the walk-behind trowel. It is extremely important
that this section be read carefully before attempting to use
the trowel in the field. DO NOT use your trowel until this
section is thoroughly understood.
Lifting the Trowel Onto a Slab
Extra care should be taken when lifting the trowel off the
ground. Serious damage to the machine or personal injury
could be caused by dropping a trowel.
*AAA Rent-All 225-291-1356*
INSPECTION/OPERATION
OFF
ON
CENTRIFUGAL
SAFETY "STOP"
SWITCH
Figure 21. Centrifugal Safety "STOP" Switch
WARNING
NEVER attempt to lift this machine alone. NEVER lift
the trowel by the guard ring as it may rotate and cause
injury.
ALWAYS make certain the handle is secure and use
only the manufacturer's approved lifting point. The
trowel may be lifted at the center lifting bale by crane
or other lifting device of adequate capacity.
NOTICE
DO NOT attempt to operate the trowel until the Safety,
General Information and Inspection sections of this
manual have been read and thoroughly understood.