Philips Domestic Appliances and Personal Care
Service Manual

PRODUCT INFORMATION

General:

- Rechargeable / Main shaver
- Constant motor voltage
- Electronic push on/off
- Washable

Safety information

- This product meets the requirements regarding
interference suppression on radio and TV.
- After the product has been repaired, it should function
properly and has to meet the safety requirements as
officially laid down at this moment.

TECHNICAL INFORMATION

- Voltage
- Motor voltage
- Speed of cutters
- Shaving heads
- Battery capacity indication : Polymer LED
- Battery full indication
- Battery low indication
- Charge indication
- Battery
- SAP coding

DISASSEMBLY- AND RE-ASSEMBLY ADVISE

Disassembly:

- Remove shaving unit, to prevent damages during
repairing.
- Remove screws A1 (2x).
- Take cover from housing (trimmer must be opened).
Published by Philips Domestic Appliances and Personal Care
04/09
: 100 - 240 Volt 50 - 60 Hz
: 3,6 Volt
: > 2100 r.p.m.
: HQ8 - 4222 036 05820
: Polymer LED
: Polymer LED
: Polymer LED
: Li-ion
: HQ8894
Printed in the Netherlands
- Remove bracket large (17).
(see figure 1)
- The PCB-board can now be
removed out of the housing.
- Remove the connecting strip
from the motor by
dis soldering.
- Remove screws B1 (2 x), now
the motor and hairchamber
can be removed out of the
housing.
- Detach the motor springs (14) from the gearwheel unit
with a small screwdriver.

Assembly:

- Think by assembly on the
hooks from the connecting
strip assy. (see figure 2)

REPAIR INSTRUCTION

- No specific issues

OPTIONAL (accessories)

- No specific issues
© Copyright reserved
Shaver
HQ8894
SENSOTEC
figure 1
figure 2
Subject to modification

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SENSOTEC HQ8894 and is the answer not in the manual?

Questions and answers

Summary of Contents for Philips SENSOTEC HQ8894

  • Page 1 - Remove shaving unit, to prevent damages during repairing. - No specific issues - Remove screws A1 (2x). - Take cover from housing (trimmer must be opened). Published by Philips Domestic Appliances and Personal Care Printed in the Netherlands © Copyright reserved Subject to modification 04/09...
  • Page 2 HQ8894 FAST SOLUTION FOR THE NEXT PROBLEM: - The shaver stops while the the batteries are just recharged. - No signal that the shaver has to be recharged. - Stops during shave. - Still minutes left on the display Service code number 4222 036 10460 Note: Capacitor provided may deviate from type shown.
  • Page 3 EXPLODED VIEW HQ8894 –...

Table of Contents