8.2
To pass the pipes through the wall
hole
1 Shape the refrigerant pipes along the pipe path marking on the
mounting plate.
a
b
c
c
d
a
Drain hose
b
Caulk this hole with putty or caulking material
c
Adhesive vinyl tape
d
Insulation tape
e
Mounting plate (accessory)
NOTICE
▪ Do NOT bend refrigerant pipes.
▪ Do NOT push the refrigerant pipes onto the bottom
frame or the front grille.
2 Pass the drain hose and refrigerant pipes through the wall hole.
8.3
To fix the unit on the mounting
plate
1 Set the indoor unit on the mounting plate hooks. Use the " "
marks as a guide.
2 Press the bottom frame of the unit with both hands to set it on
the bottom hooks of the mounting plate. Make sure that the
wires do NOT get squeezed anywhere.
Note:
Take care that the interconnection cable does NOT get
caught in the indoor unit.
3 Press the bottom edge of the indoor unit with both hands until it
is firmly caught by the mounting plate hooks.
4 Secure the indoor unit to the mounting plate using 2 indoor unit
fixing screws M4×12L (accessory).
9

Configuration

9.1

To set a different address

In case 2 indoor units are installed in 1 room, different addresses for
2 user interfaces can be set.
FTXTA30B2V1B(W)(B)
Daikin room air conditioner
3P482320-12U – 2021.03
1 Remove the cover and the batteries from the user interface.
2 Cut the address jumper J4.
e
3 Turn the power supply on.
4 Press
5 Press
6 Press the indoor unit ON/OFF switch while the operation lamp
Address jumper
Factory setting
After cutting with nippers
7 When the setting is complete, keep
Result: The user interface will return to the previous screen.
a
Address jumper J4
NOTICE
Be careful NOT to damage any of the surrounding parts
when cutting the address jumper.
and
simultaneously.
, select
and press
Result: The operation lamp will start to blink.
a
Indoor unit ON/OFF switch and operation lamp
is blinking.
Address
1
2
INFORMATION
If the setting could NOT be completed while the operation
lamp was blinking, repeat the setting process from the
beginning.
5 seconds.
9 Configuration
a
.
a
pressed for at least
Installation manual
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ftxta30b2v1bb