Page 1
Cover 7451A/61A/61P Digital Multimeter Operation Manual FOE-00000061B00 MANUAL NUMBER Applicable Models 7451A 7461A 7461P First printing January 20, 2011 2011 ADC CORPORATION All rights reserved. Printed in Japan...
Page 3
Certificate of Conformity Certificate of Conformity This is to certify, that Digital Multimeter 7451A / 7461A / 7461P instrument, type, designation complies with the provisions of the EMC Directive, 2004/108/EC in accordance with EN61326-1. and Low Voltage Directive, 2006/95/EC in accordance with EN61010.
TABLE OF CONTENTS 7451A/7461A/7461P Digital Multimeter Operation Manual TABLE OF CONTENTS INTRODUCTION ..................Contents of this Manual ..................Product Overview ....................PRECAUTIONS ..................If a Fault Occurs ....................Removing the Case ................... Power Fuse ......................Electromagnetic Interference ................Note When Turning on the Power ..............
Page 6
7451A/7461A/7461P Digital Multimeter Operation Manual Table of Contents Menu ......................... 5.1.1 How to Navigate the Menus ............... 5.1.2 Menu List ....................Measurement Functions and Parameters ............5.2.1 DC Voltage Measurement (DCV) .............. 5.2.2 DC Voltage Measurement (DCV-Bch) ............5.2.3 Continuity Measurement ................
Page 7
7451A/7461A/7461P Digital Multimeter Operation Manual Table of Contents HOW TO USE THE INTERFACE ............Interface Selection ..................... 6.1.1 Response to the *IDN? Command (7451A/61A Only) ......GPIB ........................6.2.1 Overview ....................6.2.2 Precautions in Use of GPIB ................ 6.2.3 GPIB Setting ....................
Page 8
7451A/7461A/7461P Digital Multimeter Operation Manual Table of Contents MAINTENANCE ..................Replacing Fuses ....................8.1.1 Replacing a Power Fuse ................8.1.2 Replacing a Protection Fuse ............... Cleaning ......................8.2.1 Cleaning the Outside .................. 8.2.2 Cleaning Others ..................Calibration ......................8.3.1 Preparing for Calibration ................
Page 9
7451A/7461A/7461P Digital Multimeter Operation Manual LIST OF ILLUSTRATIONS Title Page Operating Environment ..................... Electrostatic Countermeasures for the Work Floor and Human Body ......Electrostatic Countermeasures for the Workbench ............Indication of the Set Power Supply Voltage ..............Connecting the Power Cable .....................
Page 11
7451A/7461A/7461P Digital Multimeter Operation Manual LIST OF TABLES Title Page Standard Accessories ......................ESD Countermeasures ...................... Accessories ........................Relation Table between AC Power Supply Voltage and Indication of Set Power Supply Voltage 3-8 Maximum Allowable Applied Voltage (DCV) ..............Range and Input impedance (DCV) ..................
Page 12
7451A/7461A/7461P Digital Multimeter Operation Manual List of Tables Title Page Fuse Rating and Compliant Standard ................Calibration Point (7461A/61P) ..................Calibration Point (7451A) ....................Parts with Limited Life ..................... 8-11 Disposal ..........................8-12 Initial Values of Setting Parameters ................. 8-16 Self-Test Items ........................
7451A/7461A/7461P Digital Multimeter Operation Manual 1. INTRODUCTION INTRODUCTION This chapter describes the contents of this manual and the product overview of the 7451A/7461A/7461P Dig- ital Multimeter. Contents of this Manual This manual can be used by novices or experienced users of this instrument. This manual can be read from Chapter 1 to learn more about this instrument or it can be used as a reference.
High sensitivity: 0.1 V (7461A/7461P) and 1 V (7451A) in the DC voltage measurement • • Wide dynamic range: 1 nA to 3 A (7461A/7461P) and 10 nA to 3 A (7451A) in the DC current mea- surement • Low power resistance measurement function that reduces the self-heating effect of the device •...
7451A/7461A/7461P Digital Multimeter Operation Manual 2. PRECAUTIONS PRECAUTIONS This chapter describes precautions when using this instrument. Read this chapter before using this instru- ment. CAUTION: Using this instrument while it is stood on end or stacked with other products is unstable and danger- ous.
7451A/7461A/7461P Digital Multimeter Operation Manual 2.5 Note When Turning on the Power Note When Turning on the Power When turning on the power, do not connect any DUTs.
7451A/7461A/7461P Digital Multimeter Operation Manual 3. SETUP SETUP This chapter describes how to set up this instrument on delivery. The following topics are covered in this chapter. 3.1 Inspection on Delivery 3.2 Installation Environment 3.3 Accessories 3.4 Power Requirements Inspection on Delivery After receiving the product, inspect the outside and the accessories according to the following procedure.
7451A/7461A/7461P Digital Multimeter Operation Manual 3.1 Inspection on Delivery Table 3-1 Standard Accessories Name Model Quantity Remarks Power cable A01402 Input cable (Red, Black) CC010001 Each 1 Alligator clip adapter (Red, Black) CC015001 Each 1 Power Fuse (For 100V/120V) DFT-AAR25A-1...
7451A/7461A/7461P Digital Multimeter Operation Manual 3.2 Installation Environment Installation Environment This section describes the environment into which this instrument should be installed. 3.2.1 Operating Environment Install this instrument in an environment in which the following conditions are satisfied. Ambient temperature: 0 C to +50 C (operating temperature) •...
7451A/7461A/7461P Digital Multimeter Operation Manual 3.2.2 Protecting Against Electrostatic Discharge 3.2.2 Protecting Against Electrostatic Discharge To prevent semiconductors from being damaged by electrostatic discharge (ESD), the precautions shown below should be taken. We recommend combining two or more countermeasures to prevent damage from ESD.
7451A/7461A/7461P Digital Multimeter Operation Manual 3.3 Accessories Accessories The accessories of this instrument are shown in Table 3-3. This section describes the accessories necessary to use this instrument. Table 3-3 Accessories Name Model Remarks Input cable CC010001 Standard Accessory A01001...
Page 22
7451A/7461A/7461P Digital Multimeter Operation Manual 3.3.1 Input Cable Barrier Probe Protect tip Alligator clip adapter To reduce the effects of short-term stability in high resistance (in the order of M) or high sensitivity (in the order of V) measurements, use the optional input cable A01001 in which the HI side is shielded.
7451A/7461A/7461P Digital Multimeter Operation Manual 3.3.2 Caution when Connecting Peripherals 3.3.2 Caution when Connecting Peripherals When making up a system, which consists of two or more devices, be careful of the following: Before connecting this instrument to a controller and peripherals, check that each device operates cor- rectly according to each manual.
7451A/7461A/7461P Digital Multimeter Operation Manual 3.4 Power Requirements Power Requirements This section describes power requirements and how to connect the power cable. 3.4.1 Checking the Power Supply Voltage Check that the power supply voltage setting on the rear panel of this instrument accords with the AC power supply voltage to be used.
7451A/7461A/7461P Digital Multimeter Operation Manual 3.4.2 Changing the Power Supply Voltage 3.4.2 Changing the Power Supply Voltage Remove the fuse holder assembly from the rear panel. Push both side of the fuse holder assembly by using flathead screwdrivers ( and then pull it out ( Remove the power supply voltage selector from the fuse holder assembly.
Page 26
7451A/7461A/7461P Digital Multimeter Operation Manual 3.4.2 Changing the Power Supply Voltage Replace the fuse holder assembly into the rear panel. Check that the correct power supply voltage is indicated in the window. 3-10...
7451A/7461A/7461P Digital Multimeter Operation Manual 3.4.3 Connecting the Power Cable 3.4.3 Connecting the Power Cable This instrument includes a three-core power cable with a grounding conductor. To prevent accidents caused by electric shocks, only use the included power cable and securely connect to the ground through a three-pin power outlet.
7451A/7461A/7461P Digital Multimeter Operation Manual 4. QUICK START QUICK START The high speed measurement and high accuracy measurement can be performed in this digital multimeter. To make the performing operations easier, this instrument includes the following functions on the front panel.
7451A/7461A/7461P Digital Multimeter Operation Manual 4.1.1 Front Panel Description 4.1.1.1 Display Section GPIB address (My Address) Remote control Sampling indicator Calibration Sampling hold Numerical value display section Unit display section mode Sampling rate setting Fast M: Medium Slow RCL:Recall setting...
7451A/7461A/7461P Digital Multimeter Operation Manual 4.1.1 Front Panel Description LP-2W/LP-4W (SHIFT + 2W/4W Selects the low power resistance measurement. Either 2W or 4W can be selected. (SHIFT + DCI) Selects the diode measurement ( 11. AC + DC (SHIFT + ACI) Selects the AC+DC coupling or AC coupling in the AC current measurement.
7451A/7461A/7461P Digital Multimeter Operation Manual 4.1.1 Front Panel Description 4.1.1.8 SHIFT/EXIT/LOCAL Key SHIFT Sets or cancels the SHIFT mode. • In the setting mode EXIT Exits from MENU and returns to the measurement state display. (The data in process of changing the setting is not saved.) •...
7451A/7461A/7461P Digital Multimeter Operation Manual 4.1.2 Rear Panel Description 4.1.2 Rear Panel Description Figure 4-3 Rear Panel Description Power connector Used to supply the AC power by connecting the included power cable (A01402). Fuse holder assembly The power supply voltage can be selected from 100 V, 120 V, 220 V, and 240 V.
7451A/7461A/7461P Digital Multimeter Operation Manual 4.2 Basic Operation Basic Operation When the power is turned on, this instrument automatically performs the self-test and then proceeds to the measurement sequence. For more information on the detail of the self-test, refer to Chapter 8, “MAINTENANCE.”...
7451A/7461A/7461P Digital Multimeter Operation Manual 4.2.1 Measurement Functions DC voltage measurement (DCV-Bch) Press SHIFT ‘BDC’ is displayed. The measurement is performed between Bch HI and COM terminals in the fixed range of 10 V. Table 4-3 Maximum Allowable Applied Voltage (DCV-Bch)
7451A/7461A/7461P Digital Multimeter Operation Manual 4.2.1 Measurement Functions AC voltage measurement (ACV and ACV(AC+DC)) ACV measurement Press AC voltage with AC coupling is measured. Pressing continuously switches the AC filter in turn. ACV(AC+DC) measurement Press SHIFT ACV and DCV are measured and the root mean square value ( +DCV is displayed.
7451A/7461A/7461P Digital Multimeter Operation Manual 4.2.1 Measurement Functions Table 4-7 Measurement range 7461A/61P 7451A Measurement method TrueRMS Measurement range 5% or more of the range Crest factor 1000Vpeak AC700Vrms or less 2.2 10 500V or less Figure 4-6 AC Voltage Measurement (ACV and ACV(AC+DC)) Resistance measurement (2W, 4W, LP-2W, and LP-4W)
7451A/7461A/7461P Digital Multimeter Operation Manual 4.2.1 Measurement Functions Table 4-8 Maximum Allowable Applied Voltage (2W, 4W, LP-2W, LP-4W) Between and COM 1000 Vpeak *1 Between 4WHI and LO 200 Vpeak Between 4WHI/LO and COM 200 Vpeak Between COM and chassis...
7451A/7461A/7461P Digital Multimeter Operation Manual 4.2.1 Measurement Functions DC current measurement (DCI) Press Maximum allowable applied current WARNING: Must not measure the current source whose potential is more than 250 V. This instrument may be damaged and injury accidents may be caused.
7451A/7461A/7461P Digital Multimeter Operation Manual 4.2.1 Measurement Functions AC current measurement (ACI and ACI(AC+DC)) ACI measurement Press AC current with AC coupling is measured. Pressing continuously switches the AC filter in turn. ACI(AC+DC) measurement Press SHIFT ACI and DCI are measured and the root mean square value (...
Page 41
7451A/7461A/7461P Digital Multimeter Operation Manual 4.2.1 Measurement Functions Table 4-10 Measurement Range 7461A/61P 7451A Measurement method TrueRMS Measurement range 5% or more of the range Crest factor *1 Except for the 3 A range DC 3A or less AC3Arms or less ...
Page 42
7451A/7461A/7461P Digital Multimeter Operation Manual 4.2.1 Measurement Functions Continuity measurement ( FREQ Press SHIFT The resistance is measured in 2W. If the measured resistance is lower than the continuity threshold constant, the buzzer sounds. Table 4-11 Continuity Measurement 7461A/61P 7451A 1000 ...
7451A/7461A/7461P Digital Multimeter Operation Manual 4.2.1 Measurement Functions Diode measurement ( Press SHIFT The voltage between the terminals is measured while the current of about 1 mA is applied to the diode. Table 4-12 Diode Measurement 7461A/61P 7451A Measurement range...
7451A/7461A/7461P Digital Multimeter Operation Manual 4.2.1 Measurement Functions Frequency measurement (FREQ) FREQ Press The frequency in the ACV measurement function is displayed. The DC component of the input signal is cut by using the AC coupling and the frequency is measured at the zero-cross point.
7451A/7461A/7461P Digital Multimeter Operation Manual 4.2.1 Measurement Functions 10. Temperature measurement (TEMP-2W, TEMP-3W, TEMP-4W) TEMP Press The temperature is measured by using the 2W, 3W or 4W (formerly set method). Table 4-14 Temperature Measurement Resistance bulb Pt100 JPt100 -200 C to +850 C -200 C to +649 C...
Page 46
7451A/7461A/7461P Digital Multimeter Operation Manual 4.2.1 Measurement Functions Current (a) 2W measurement Current (b) 3W measurement Current (c) 4W measurement Figure 4-13 Temperature Measurement 4-18...
7451A/7461A/7461P Digital Multimeter Operation Manual 4.2.2 Setting the Measurement Range 4.2.2 Setting the Measurement Range Increases the measurement range by one level and fixes the range. DOWN Decreases the measurement range by one level and fixes the range. AUTO Switches the measurement range between auto-range and fixed range.
7451A/7461A/7461P Digital Multimeter Operation Manual 5. MENU OPERATION AND FUNCTION DESCRIPTION MENU OPERATION AND FUNCTION DESCRIPTION Menu The functions and conditions in this instrument are set by using layered menus. 5.1.1 How to Navigate the Menus Menus have a three-layer structure. (Some menus have a four-layer structure.)
Page 50
7451A/7461A/7461P Digital Multimeter Operation Manual 5.1.1 How to Navigate the Menus Press MENU The Category layer in which be selected is displayed. 1 MEAS 9 SYS Select the category by using Press The Selection layer is displayed. Select the parameters by using Press The Entry/Execution layer is displayed.
7451A/7461A/7461P Digital Multimeter Operation Manual 5.1.1 How to Navigate the Menus Table 5-1 Menu Operation Key and Function Entry/Execution layer Numerical value parameter Category layer Selection layer Selectable parameter/ Parameter: Dark display, Target items: Numerical execution item No blinking value/decimal point/unit...
OFF/ON/ONCE IT SEC Integration time (sec) 10 sec to 10 sec (For 7461A/61P) 100 sec to 10 sec (For 7451A) IT PLC Integration time (PLC) 0.02 PLC to 100 PLC When the integration time is outside this range, it is set in seconds.
Page 53
N.Smpl Number of samples 1 to 16000 Sampling interval 50 s to 3600 s (For 7461A/61P) 200 s to 3600 s (For 7451A) Trigger source Selection IMMED/MAN/EXT/BUS/LEVEL/DELTA LEVEL Level count value (For the trigger source is set to only LEVEL)
Page 54
7451A/7461A/7461P Digital Multimeter Operation Manual 5.1.2 Menu List Category layer Selection layer Entry/Execution layer HIGH HIGH constant 4 CONST -9999.999E+9 to 9999.999E+9 (For 7461A/61P) -999.999E+9 to 999.999E+9 (For 7451A) LOW constant -9999.999E+9 to 9999.999E+9 (For 7461A/61P) -999.999E+9 to 999.999E+9 (For 7451A) ...
Page 55
7451A/7461A/7461P Digital Multimeter Operation Manual 5.1.2 Menu List Category layer Selection layer Entry/Execution layer Interface selection 8 I/F GPIB/USB GP.Adr GPIB address (Only when GPIB is selected for the interface) 0 to 30 USBid USB ID (Only when USB is selected for the interface)
Page 56
7451A/7461A/7461P Digital Multimeter Operation Manual 5.1.2 Menu List Category layer Selection layer Entry/Execution layer WIRE Measurement wire connection 10 TEMP 2W/3W/4W * 7461P only TYPE Platinum resistance bulb selection PT/JPT UNIT Temperature unit C/F/K...
The input impedance in the following range can be selected from HiZ and 10 M. 100 mV, 1000 mV, and 10 V ranges (7461A/61P) 300 mV and 3000 mV ranges (7451A) Select HiZ or 10 M from ‘ZIn’ in 1 MEAS...
7451A/7461A/7461P Digital Multimeter Operation Manual 5.2.3 Continuity Measurement 5.2.3 Continuity Measurement Setting the continuity threshold constant The continuity threshold constant can be selected in the range between 1 and 1000 from ‘BEEP’ in 1 MEAS category in MENU...
7451A/7461A/7461P Digital Multimeter Operation Manual 5.3 Measurement Range and Auto-Range Measurement Range and Auto-Range 5.3.1 Measurement Function and Range Structure Table 5-2 shows the range structure corresponding to the measurement function. Table 5-2 Measurement Function and Range Structure 2W/ LP-2W/...
7451A/7461A/7461P Digital Multimeter Operation Manual 5.3.2 Auto-range 5.3.2 Auto-range When Auto-range is set to ON, the measurement range of this instrument automatically changes to the optimum range depending on the input voltage. The judgment value used when the range is changed...
7451A/7461A/7461P Digital Multimeter Operation Manual 5.4 Auto-Zero Operation Auto-Zero Operation Auto-zero function eliminates the offset error in the measurement system of this instrument. Set Auto-zero in ‘A.Zero’ in 1 MEAS MENU If Auto-zero is set to ON, the internal offset is measured and the offset error is eliminated because the offset is subtracted from the input measurement value.
7451A/7461A/7461P Digital Multimeter Operation Manual 5.5 Display Mode Setting If ONCE is set and Auto-zero is performed, the offset error is eliminated and then Auto-zero is turned off. If the resolution and measurement speed are changed by using the RATE key, Auto-zero is switched ON or OFF.
7451A/7461A/7461P Digital Multimeter Operation Manual 5.7 Sampling Operation Sampling Operation Figure 5-2 shows the measurement sequence of this instrument. Measurements are performed when the trigger event is received. When each measurement is complete, the COMPLETE signal is output and the data output starts.
7451A/7461A/7461P Digital Multimeter Operation Manual 5.7.1 Sampling Interval (SI) and Integration Time (IT) Settings 5.7.1 Sampling Interval (SI) and Integration Time (IT) Settings The integration time and sampling interval can be set by using MENU as well as the RATE key on the front panel.
7451A/7461A/7461P Digital Multimeter Operation Manual 5.7.1 Sampling Interval (SI) and Integration Time (IT) Settings Table 5-5 shows the setting range of the sampling interval. Table 5-5 Setting Range of Sampling Interval (SI) 7461A/61P 7451A Setting range Setting range 50 s to 3600 s 200 s to 3600 s...
When data is stored in the measurement data memory in conjunction with this setting on the 7461A or 7451A, the number of data to be stored is up to 10,000 even if the number of sampling is set to more than 10,000.
7451A/7461A/7461P Digital Multimeter Operation Manual 5.8 Trigger Function Trigger Function The trigger system of this instrument allows trigger detection, the sampling start to be delayed, and multiple samplings per trigger. Figure 5-3 shows the trigger model. IDLE state :ABORt *RST...
7451A/7461A/7461P Digital Multimeter Operation Manual 5.8.1 Trigger System Operation 5.8.1 Trigger System Operation IDLE state The trigger system is in the IDLE state before the trigger sequence starts, after the trigger sequence is terminated, and while the processes of this system are not performed such as a reset state.
7451A/7461A/7461P Digital Multimeter Operation Manual 5.8.2 Trigger Source Selection 5.8.2 Trigger Source Selection The trigger source is selected in 'SRC' in the 2 TRIG category in MENU Trigger source IMMED Performs the continuous measurement at the timing of the sampling interval in this instrument.
Page 70
7451A/7461A/7461P Digital Multimeter Operation Manual 5.8.2 Trigger Source Selection [Measurement timing according to the trigger source] A: HOLD: OFF 1. TRIGger:Source:IMMediate Measurement Measurement Measurement Measurement Complete Complete Complete Complete SI=TRIGger:TIMer<n> TRIGger:DELay is invalid. HOLD: ON 2. TRIGger:Source:MANual Example of Cs = 4...
Procedure Set the trigger source to LEVEL or DELTA. Set the sampling count. (7451A/61A: up to 10000, 7461P: up to 16000) Set the parameter for detecting a trigger level.(LEVEL, SLOPE, DELTA, PATRN) The measurement in the set sampling interval starts when the...
Set LEVEL to 500000 when setting the threshold level to 5.00000 V in DCV 10V range of the 7461A. If the setting exceeds the maximum display, the trigger cannot be detected. Example: When LEVEL is set to 200000 in DCV-Bch of the 7451A. 5-25...
7451A/7461A/7461P Digital Multimeter Operation Manual 5.8.5 Level Trigger and Delta Trigger 5.8.5.2 Delta Trigger An event is detected when the difference between delta 1 and delta 2 exceeds the set DELTA (threshold value). Example: SLOPE:POSI, PATRN:CONV The trigger is detected when 1 is larger than DELTA and 2 is smaller than DELTA.
If the setting exceeds the maximum display, the trigger cannot be detected. Example: When DELTA is set to 200000 in DCV-Bch of the 7451A. The trigger is detected when the polarity of change and direction of change judgment conditions are satis- fied (refer to Table 5-8).
Although the data before the trigger event is stored in the measurement data memory by setting the pre- trigger, the total data amount cannot exceed the capacity of the data memory. The 7451A/61A stores up to 10000 data and the 7461P stores up to 20000 data.
7451A/7461A/7461P Digital Multimeter Operation Manual 5.9 Calculation Functions • Memory recall Reads out the number of measurement results IRPO? Outputs the number of valid measurement results. Example of reply: IRPO01000 Reads out the data range IRNO? Outputs the range of valid data.
7451A/7461A/7461P Digital Multimeter Operation Manual 5.9 Calculation Functions Calculation Smoothing Measurement NULL Comparator Scaling Results data Number of data Statistics Data memory Maximum value Minimum value Average value Standard deviation Dispersion MAX/MIN Number of data Maximum value Minimum value Average value...
7451A/7461A/7461P Digital Multimeter Operation Manual 5.9.1 NULL Calculation 5.9.1 NULL Calculation Function The NULL calculation subtracts the NULL constant from the measurement value and outputs the re- sult. Measurement data output = Measurement value - NULL constant Pressing the key performs the calculation and turns on the NULL lamp in the display sec- NULL tion.
7451A/7461A/7461P Digital Multimeter Operation Manual 5.9.2 Smoothing Calculation • Decimal point Change the setting value by using at the blinking position. The unit prefix is switched according to the following order. p n m No unit prefix k M G T Press to apply the setting.
Page 81
7451A/7461A/7461P Digital Multimeter Operation Manual 5.9.2 Smoothing Calculation When the smoothing count, N, is set to 3, the operation is as follows. Smoothing start Measured value Measurement value output (D3+D4)/2 (D3+D4+D5)/3 (D4+D5+D6)/3 (D5+D6+D7)/3 The SM The SM lamp blinks. lamp turns on.
Page 82
7451A/7461A/7461P Digital Multimeter Operation Manual 5.9.2 Smoothing Calculation Canceling the smoothing calculation The smoothing calculation is canceled when any of the following conditions occur. • The key is pressed while the smoothing calculation is performed. • The measurement function is changed.
7451A/7461A/7461P Digital Multimeter Operation Manual 5.9.3 Scaling Calculation 5.9.3 Scaling Calculation Function The scaling calculation equation is shown below. Measurement value M - Constant B Constant C Display = Constant A When SCL is selected from the MATH item in...
Page 84
7451A/7461A/7461P Digital Multimeter Operation Manual 5.9.3 Scaling Calculation Setting the numerical value of the constant The setting ranges of Constants A, B, and C are shown below. Minimum Constant Setting range resolution 0.000001E - 9 7461A/61P -9999999.E +6 to +9999999.E + 6 0.000000E - 9...
7451A/7461A/7461P Digital Multimeter Operation Manual 5.9.4 dB and dBm calculation 5.9.4 dB and dBm calculation Function The dB calculation, in which the decibel conversion is performed, can be performed only in the volt- age and current measurements. The dBm calculation, which is useful to calculate the power gain per 1 mV, can be performed only in the voltage measurement.
Page 86
7451A/7461A/7461P Digital Multimeter Operation Manual 5.9.4 dB and dBm calculation Setting Constant D The setting range of Constant D is shown below. Setting range Minimum resolution 7461A/61P 0.000001E -9 to 9999999.E + 6 0.000001E - 9 7451A 0.000001E -9 to 999999.E + 6 The exponential part is set by using a unit prefix (p, n, , m, k, M, G, T).
7451A/7461A/7461P Digital Multimeter Operation Manual 5.9.5 Comparator Calculation 5.9.5 Comparator Calculation Function The comparator calculation equation is shown below. HI = (Measurement value > HI setting value) LO = (Measurement value < LOW setting value) GO = (LOW setting value Measurement value HI setting value) (Processing the special data) •...
Page 88
7451A/7461A/7461P Digital Multimeter Operation Manual 5.9.5 Comparator Calculation Setting the numerical value of the constant The setting ranges of the High and Low constants are shown below. Constant Setting range Minimum resolution High 7461A/61P -9999999.E +6 to +9999999.E + 6 0.0000001E - 9...
Page 89
7451A/7461A/7461P Digital Multimeter Operation Manual 5.9.5 Comparator Calculation PASS condition setting In the PASS condition setting, each comparator calculation result (HI, GO, and LO) is specified as either PASS or not. For example, if HI is specified as the PASS condition and LO and GO are not specified as the PASS conditions, the comparator measurement result of HI is judged as PASS.
7451A/7461A/7461P Digital Multimeter Operation Manual 5.9.6 MAX/MIN Calculation 5.9.6 MAX/MIN Calculation Function This function calculates the maximum, minimum, and average values while the MAX/MIN calculation is performed. The following calculations are performed at the same time in the MAX/MIN cal- culation.
Page 91
7451A/7461A/7461P Digital Multimeter Operation Manual 5.9.6 MAX/MIN Calculation How to call the MAX/MIN calculation result Select RSLT in MENU to see the calculation results display. MENU ..3.. CALC RSLT Measurement count Maximum value Minimum value Average value Select a display item by pressing The measurement count, maximum value, minimum value, and average value are displayed in this order.
7451A/7461A/7461P Digital Multimeter Operation Manual 5.9.7 Statistical Calculation 5.9.7 Statistical Calculation Function This function calculates the maximum value, minimum value, average value, standard deviation, and range of the measurement data that is stored in the mea- surement memory. The following calculations are performed at the same time in the statistical cal- culation.
Page 93
7451A/7461A/7461P Digital Multimeter Operation Manual 5.9.7 Statistical Calculation How to call the calculation result The display item of the calculation results can be selected in STAT in MENU MENU ..7.. MEM SAMPL (Number of samples) STAT (Maximum value) (Minimum value)
7451A/7461A/7461P Digital Multimeter Operation Manual 5.10 Saving and Loading the Measurement Condition Settings 5.10 Saving and Loading the Measurement Condition Settings In this instrument, four files of measurement condition setting parameters can be saved in non-volatile mem- ory USER0 to USER3.
7451A/7461A/7461P Digital Multimeter Operation Manual 5.11 Storing and Recalling the Measurement Data 5.11 Storing and Recalling the Measurement Data This instrument includes the measurement data memory, in which the following number of measurement results can be stored. • 7451A/61A: 10000 data •...
7451A/7461A/7461P Digital Multimeter Operation Manual 5.12 System Settings 5.12 System Settings 5.12.1 Buzzer Setting Select ON or OFF in ‘BEEP’ in 9 SYS MENU The buzzer sounds. The buzzer does not sound. The buzzer does not sound regardless of the result of comparator calculation.
7451A/7461A/7461P Digital Multimeter Operation Manual 5.12.3 Disabling Functions using Press ENTER to apply the setting. • The relationship according to disabling the function setting Although the ENA or DIS can be set for each function, some functions are automatically disabled depending on the settings of other functions.
7451A/7461A/7461P Digital Multimeter Operation Manual 5.12.4 Front Panel Disabling Function 5.12.4 Front Panel Disabling Function This function disables all panel keys on the front panel in this instrument. The following shows how to set the front panel disabling function. Password setting The password is required to enable or disable the front panel keys.
Page 99
7451A/7461A/7461P Digital Multimeter Operation Manual 5.12.4 Front Panel Disabling Function Panel lock setting Set the panel lock according to the following procedure. Character Operation display section MENU MENU Press and select 9 SYS by using Press BEEP Select ‘P.Lock’ by using P.Lock...
7451A/7461A/7461P Digital Multimeter Operation Manual 5.12.5 Error Queue Canceling the panel lock Cancel the panel lock according to the following procedure. Character Operation display section 1. If pressing any key while the panel lock is set, the entry layer of P.Lock is set.
6.1.1 Response to the *IDN? Command (7451A/61A Only) This instrument has changed its model name from “AD7451A/AD7461A” to “7451A/7461A.” Accord- ingly, the response to the *IDN? command has also been changed. Note that an old model name response can also be set to maintain the compatibility with the application software.
Page 102
7451A/7461A/7461P Digital Multimeter Operation Manual 6.1.1 Response to the *IDN? Command (7451A/61A Only) Specification of response to *IDN? New model name ADC Corp.,xxxxx,nnnnnnnnn,mmm response xxxxx: 7451A or 7461A (Product model name) nnnnnnnnn: Serial No. mmm: Revision No. Old model name...
7451A/7461A/7461P Digital Multimeter Operation Manual 6.2 GPIB GPIB 6.2.1 Overview The automatic measurement system can be set up easily by using GPIB (General Purpose Interface Bus) because measurement functions and parameters can be set and measurement data can be read by using the external control.
7451A/7461A/7461P Digital Multimeter Operation Manual 6.2.2 Precautions in Use of GPIB 6.2.2 Precautions in Use of GPIB Do not use too long a bus cable to connect any instrument or controller. Ensure that the total cable length does not exceed 20 m. ADC CORPORATION uses the following cables as the standard bus cable.
7451A/7461A/7461P Digital Multimeter Operation Manual 6.2.3 GPIB Setting 6.2.3 GPIB Setting The following setting menu can be used when the GPIB is selected as the interface. Address setting Operations Display MENU MENU Press and select by using 8 I/F Press ENTER to move to the I/F category layer.
Page 106
7451A/7461A/7461P Digital Multimeter Operation Manual 6.2.3 GPIB Setting Talk-Only setting Operations Display MENU MENU Press and select 8 I/F by using the keys. Press ENTER to move to the I/F category layer. Select BUS by using the keys. Press to move to the BUS selection layer.
7451A/7461A/7461P Digital Multimeter Operation Manual 6.3 USB 6.3.1 Overview A USB (Universal Serial Bus), which is compliant with the USB2.0 Full Speed, is included in this instru- ment as standard. By connecting multiple instruments to the USB ports on a personal computer, the functions of the instru- ments can be set, measurement data can be read from the personal computer, and the automatic measure- ment system can be set up easily.
7451A/7461A/7461P Digital Multimeter Operation Manual 6.4 Control Signal 6.3.3.2 USBid Setting The USBid setting menu can be used when USB is selected for the interface. Enter any address from 1 to 127 in ‘USBid’ in 8 I/F MENU Press ENTER to apply the setting.
7451A/7461A/7461P Digital Multimeter Operation Manual 6.4.2 Measurement Complete Signal Terminal (COMPLETE OUT) 6.4.2 Measurement Complete Signal Terminal (COMPLETE OUT) A negative logic pulse is output from the measurement complete signal terminal (COMPLETE OUT) on the rear panel when the measurement is complete.
Page 110
7451A/7461A/7461P Digital Multimeter Operation Manual 6.4.2 Measurement Complete Signal Terminal (COMPLETE OUT) Complete signal output timing The typical value of the complete signal output timing under the following setting conditions is shown. Function: DCV, Auto-zero: OFF, Auto-range: OFF Single output Time from the trigger signal input at the external trigger terminal to the complete signal output: Tc Tc=Tin ...
Page 111
7451A/7461A/7461P Digital Multimeter Operation Manual 6.5 Comparator Output Comparator Output The comparator calculation result is output from the comparator output terminal (COMPARATOR) on the rear panel as the TTL signal and the optical semiconductor relay contact signal. Specifications Connector D-Sub9 pin...
7451A/7461A/7461P Digital Multimeter Operation Manual 6.5 Comparator Output The calculation result signals of Hi, Go, and Lo are output to the signal output pins of HI, PASS, and LO. The output to the PASS pin depends on the PASS conditions as shown in Table 6-3 and Table 6-4.
7451A/7461A/7461P Digital Multimeter Operation Manual 6.6 Digital Output (7461P Only) Digital Output (7461P Only) The TTL signal or the optical semiconductor relay contact signal can be output arbitrarily from the compar- ator output terminal (COMPARATOR) on the rear panel by using the remote commands.
7451A/7461A/7461P Digital Multimeter Operation Manual 6.6 Digital Output (7461P Only) Table 6-6 SCPI Commands Command Description :DOUTput:STATe {OFF|ON} Digital output disabled/enabled :DOUTput:STATe? Query of digital output :DOUTput:BITS {0-31} Digital output setting Controls arbitrarily the TTL signal or relay contact signal corresponding to 5 bits.
SCPI: SCPI Command (GPIB only) ADC: Command used in ADC CORPORATION (GPIB/USB only) R6552: Command used in ADC CORPORATION's R6552 (only 7451A, GPIB only) For more information on operations, refer to “R6552 Series Digital Multimeter Operation Manual”. 6.7.1.1 Compatibility If the R6552 command is selected, this instrument receives the R6552 command and executes it.
7451A/7461A/7461P Digital Multimeter Operation Manual 6.7.2 Output Data Format Command enabled when Command disabled when R6552 is selected R6552 is selected STP n RCLP n BZ n Note that the descriptions of the sampling rate setting commands vary depending on the selected language...
Page 117
7451A/7461A/7461P Digital Multimeter Operation Manual 6.7.2 Output Data Format With header S DD...DD EDD , S DD...DD EDD , Without header In the above case, header (1) and space (2) are not output. Main header of 3 characters ( ) + Sub header of 1 character (...
Page 118
7451A/7461A/7461P Digital Multimeter Operation Manual 6.7.2 Output Data Format Sub header Description Priority Error information Range over Calculation Scaling error Err D (dB/dBm calculation error) Calculation result infor- Comparator result HIGH mation MAX data MIN data dB data dBm data...
Page 119
7451A/7461A/7461P Digital Multimeter Operation Manual 6.7.2 Output Data Format Measurement data • 7461A/61P E (6 1/2-digit display) 9.999999E+37 Overload (OL) 9.999999E+36 OVER of the scaling calculation result 9.999999E+35 dB/dBm calculation error • 7451A E (5 1/2-digit display) 9.99999E+37 Overload (OL) 9.99999E+36...
7451A/7461A/7461P Digital Multimeter Operation Manual 6.7.3 ADC Command Reference 6.7.3 ADC Command Reference This section describes the ADC command reference of this instrument. “Initial value” shows the status when the *RST command is executed. CAUTION: Ensure the following when using the USB interface.
Page 123
Store: OFF memory Store: ON Reply: ST0 or ST1 IRDn, m Readout range setting (0, 0) n, m: 0 to 9999 (7451A/61A) 0 to 19999 (7461P) • Parameters cannot be omitted. IRO? Data reading Reply: See Section 6.7.2, “Output Data Format.”...
Page 124
EMISSION (Divergence) TDC? Reply: TDC0 or TDC1 n:50 s to 3600 s (7461A/61P) Sampling interval TRTn (500 ms) n:200 s to 3600 s (7451A) TRT? Reply: TRT+d.ddddddEdd (The position of the decimal point depends on the set- ting.) Trigger delay TRDn...
Page 125
7451A/7461A/7461P Digital Multimeter Operation Manual 6.7.3 ADC Command Reference Item Command Description Initial value Trigger system Pre-trigger value PTL0 0% (OFF) (LEVEL/DELTA PTL1 trigger) PTL2 PTL3 PTL? Reply: PTLd Complete signal TRCM0 SINGLE output mode TRCM1 MULTI TRCM? Reply: TRCM0 or TRCM1...
Page 126
7451A/7461A/7461P Digital Multimeter Operation Manual 6.7.3 ADC Command Reference Initial Item Command Description value Measurement Measurement range 7461A/61P condition 2W 4W Freq (AC+DC) (AC+DC) 2W 4W AUTO AUTO AUTO AUTO AUTO AUTO AUTO AUTO AUTO AUTO AUTO 100 100 ...
Page 127
3 1/2-digit display digits 4 1/2-digit display 5 1/2-digit display 6 1/2-digit display (7461A/61P only) Reply : One of RE3 to RE6 (7461A/61P) : One of RE3 to RE5 (7451A) AC filter*2 FAST SLOW Reply: One of FL1 to FL3 Auto-zero ONCE (Auto-zero is set to OFF after executing once.)
Page 128
7451A/7461A/7461P Digital Multimeter Operation Manual 6.7.3 ADC Command Reference Initial Item Command Description value Calculation NULL calculation Reply: NL0 or NL1 KNLn NULL constant setting n:-9999999.E+6 to +9999999.E+6 (7461A/61P) n:-999999.E+6 to +999999.E+6 (7451A) Setting resolution: 0.000001E-9 Note: The setting is disabled when the NULL calculation is set to OFF.
Page 129
7451A/7461A/7461P Digital Multimeter Operation Manual 6.7.3 ADC Command Reference Initial Item Command Description value Calculation Scaling calculation Reply: KCd.ddddddEdd (7461A/61P) Reply: KCd.dddddEdd (7451A) dB/dBm calculation dB calculation OFF dB calculation ON dBm calculation ON Reply: One of DB0 to DB2 Constant D n:0.000001E-9 to 9999999.E+6 (7461A/61P)
Page 130
SIRDn, m Statistical calculation range setting and performing the calculation (0, -1) calculation n, m: 0 to 9999 (7451A/61A) n, m: 0 to 19999 (7461P) Note: 1. An error occurs if no data exists in the range set by the measurement data memory.
Page 131
7451A/7461A/7461P Digital Multimeter Operation Manual 6.7.3 ADC Command Reference Initial Item Command Description value Calculation Statistical SAVE? Average value reading calculation Reply: SAVEd.ddddddEdd (7461A/61P) *3 Reply: SAVEd.dddddEdd (7451A) SSIG? Standard deviation value reading Reply: SSIGd.ddddddEdd (7461A/61P) *3 Reply: SSIGd.dddddEdd (7451A) However, if the number of samples is 1 or less: Outputs SSIG+9.999999E+30 (7461A/61P)
Page 132
Instrument *IDN? New model name response information ADC Corp.,xxxxx,nnnnnnnnn,mmm *For 7461P, new xxxxx: 7451A, 7461A or 7461P (Product model name) model name nnnnnnnnn: Serial No. response only mmm: Revision No. The new model name response is applied to software revi- sion C00 or later.
Page 133
7451A/7461A/7461P Digital Multimeter Operation Manual 6.7.3 ADC Command Reference Item Command Description Initial value System Status *CLS Clears each status byte. *STB? Reads the status byte register Reply: ddd *SREn Sets the service request enable register (SRER). n: 0 to 255 (However, bit6 cannot be set.)
Page 134
7451A/7461A/7461P Digital Multimeter Operation Manual 6.7.3 ADC Command Reference Item Command Description Initial value System Calibration CAL0 Sets the calibration mode to OFF. (Writes the calibration factor when leaving the calibration mode.) CAL1 Sets the calibration mode to ON. CAL?
7451A/7461A/7461P Digital Multimeter Operation Manual 6.7.4 SCPI Command Reference 6.7.4 SCPI Command Reference 6.7.4.1 SCPI Command Reference Syntax This section describes the syntax to explain each SCPI command. Descriptions of each command include the following items: Function description SCPI command...
Page 136
7451A/7461A/7461P Digital Multimeter Operation Manual 6.7.4 SCPI Command Reference • [Parameter] Describes a parameter required for sending a command. When the parameter is a numeric type or a character (string) type, it is enclosed in angle brackets (< >). If the parameter is optional, it is enclosed in braces { }.
7451A/7461A/7461P Digital Multimeter Operation Manual 6.7.4 SCPI Command Reference 6.7.4.2 Remote Command Measurement command Function description SCPI command Parameter Query reply Setting the DCV measurement :MEASure? Refer to Section 6.7.2, function and sending the read out “Output Data Format.” request at the same time 1Performing the measurement :MEASure:<Function>?
Page 139
7451A/7461A/7461P Digital Multimeter Operation Manual 6.7.4 SCPI Command Reference Function description SCPI command Parameter Query reply AC filter setting [:SENSe]:<Function>:FILTer {FAST|MED|SLOW} {FAST|MED|SLOW} The setting is enabled in the ACV, ACV(AC+DC), ACI, and ACI(AC+DC) functions. Auto-zero setting [:SENSe]:ZERO:AUTO {ON,1|OFF,0|ONCE} {1|0} Continuity threshold constant...
Page 140
7451A/7461A/7461P Digital Multimeter Operation Manual 6.7.4 SCPI Command Reference Calculation function command Function description SCPI Command Parameter Query reply NULL Calculation setting [:SENSe]:<Function>:REFerence:STATe {ON,1|OFF,0} {1|0} NULL constant setting [:SENSe]:<Function>:REFerence [-9999999.E+6|0| <real_6> (7461A/61P) The setting is enabled when 9999999.E+6] <real_5> (7451A)
Page 141
7451A/7461A/7461P Digital Multimeter Operation Manual 6.7.4 SCPI Command Reference Function description SCPI Command Parameter Query reply Whether to set the calculation :CALCulate:LIMit:PASS:UPPer {ON,1|OFF,0} {1|0} result HI to PASS. Buzzer setting :CALCulate:LIMit:BEEPer {OFF|FAIL|PASS} {OFF|FAIL|PASS} Statistical calculation Calculation range specifying :CALCulate:STATistics [0|0|9999], [0|-1|9999] <int_4>,<int_4>...
Page 142
7451A/7461A/7461P Digital Multimeter Operation Manual 6.7.4 SCPI Command Reference Trigger system command Function description SCPI Command Parameter Query reply Trigger system starting :INITiate Continuous setting :INITiate:CONTinuous {ON,1|OFF,0} {1|0} Trigger system initialization and :READ? Refer to Section 6.7.2, measurement data reading “Output Data Format.”...
Page 143
7451A/7461A/7461P Digital Multimeter Operation Manual 6.7.4 SCPI Command Reference System relevant command Function description SCPI Command Parameter Query reply Buzzer Setting :SYSTem:BEEPer:STATe {ON,1|OFF,0} {1|0} Error queue reading :SYSTem:ERRor? <int_3>,<str> SCPI version reading :SYSTem:VERSion? <str> Block delimiter :SYSTem:GPIB:DELimiter:BLOCk {CRLF|LF|EOI} {CRLF|LF|EOI} Power supply frequency...
7451A/7461A/7461P Digital Multimeter Operation Manual 6.7.5 Status Register Structure 6.7.5 Status Register Structure This instrument has a layered status register structure that is compliant with IEEE standard 488.2-1987 and can send various statuses of this instrument to the controller. This section describes the operation model of status structure and allocation of events.
7451A/7461A/7461P Digital Multimeter Operation Manual 6.7.5 Status Register Structure The status register structure in this instrument is shown in Figure 6-4 and Figure 6-5. SRQ transmitting Figure 6-4 Status Register Structure (1/2) 6-46...
7451A/7461A/7461P Digital Multimeter Operation Manual 6.7.5 Status Register Structure Figure 6-5 Status Register Structure (2/2) Event enable register Each event register has an enable register that determines which bit is to be enabled. The enable reg- ister sets the corresponding bit in decimal.
7451A/7461A/7461P Digital Multimeter Operation Manual 6.7.5 Status Register Structure • Questionable Event Enable Register (QEER): QSE • Operation Event Enable Register (OEER) OSE Status byte register The status byte register summarizes the information from the status register. A summary of this status byte register is sent to the controller as a service request.
7451A/7461A/7461P Digital Multimeter Operation Manual 6.7.5 Status Register Structure This register responds to the serial polling from the controller. When the register responds to the serial polling, bit0 to bit5, bit7, and the RQS of the status byte register are read, and then the RQS is reset to 0.
Page 150
7451A/7461A/7461P Digital Multimeter Operation Manual 6.7.5 Status Register Structure Conditions which clear the status byte register • When the power is turned on. • When the *CLS command is executed. However, the MAV bit is not cleared if data exists in the output buffer.
7451A/7461A/7461P Digital Multimeter Operation Manual 6.7.5 Status Register Structure Standard event status register Allocation in the standard event register is shown in Table 6-8. Table 6-8 Standard Event Status Register (SESR) Name Description ON: This bit is set to 1 when all operations are complete after receiving the *OPC Operation Complete command.
7451A/7461A/7461P Digital Multimeter Operation Manual 6.7.5 Status Register Structure Measurement event register Allocation in the measurement event register is shown in Table 6-9. Table 6-9 Measurement Event Register (MER) Name Description ON: This bit is set to 1 when the comparator calculation result satisfies the FAIL FAIL conditions.
7451A/7461A/7461P Digital Multimeter Operation Manual 6.7.5 Status Register Structure Questionable event register Allocation in the questionable event register is shown in Table 6-10. Table 6-10 Questionable Event Register (QER) Name Description Voltage Overload ON: This bit is set to 1 when OL occurs in the voltage or diode measurement.
7451A/7461A/7461P Digital Multimeter Operation Manual 6.7.5 Status Register Structure Operation event register Allocation in the operation event register is shown in Table 6-11. Table 6-11 Operation Event Register (OER) Name Description Not used Always 0 Not used Always 0 Not used...
Compatible language: Microsoft Excel Visual Basic for Application NOTE: These samples are programmed assuming that the 7461A is used. If the 7451A is used, change the settings such as a range configuration which depends on the multimeter. Example 1 Measures a voltage in the DCV 10 V range and reads the measurement data from the 7461A.
Page 156
7451A/7461A/7461P Digital Multimeter Operation Manual 6.8 Sample Programs (Command used in ADC CORPORATION) Example 2 Sets the measurement function to the 2W measurement, detects the measurement end by using the status byte, and reads the measurement data from the 7461A. The GPIB address of the 7461A is set to 1.
Page 157
7451A/7461A/7461P Digital Multimeter Operation Manual 6.8 Sample Programs (Command used in ADC CORPORATION) Call ibconfig(0, IbcAUTOPOLL, 0) ' Disables the automatic serial polling. (Note) Call ibwrt(dmm, "*RST" & Chr(10)) ' Initializes the 7461A. Call ibwrt(dmm, "H0" & Chr(10)) ' Sets the header of the output data to OFF.
Page 158
7451A/7461A/7461P Digital Multimeter Operation Manual 6.8 Sample Programs (Command used in ADC CORPORATION) Call ibwrt(dmm, "DS1" & Chr(10)) ' Sets the display to ON. ' Terminates. Call ibonl(dmm, 0) (Note): The GPIB hardware setting is changed. Return to the original setting if other programs may case a failure.
Compatible language: Microsoft Excel Visual Basic for Application NOTE: These samples are programmed assuming that the 7461A is used. If the 7451A is used, change the settings such as a range configuration which depends on the multimeter. Example 1 Measures the D.U.T in the DCV 10 V range and reads the measurement data from the 7461A.
Page 160
7451A/7461A/7461P Digital Multimeter Operation Manual 6.9 Sample Programs (SCPI command) Example 2 Sets the measurement function to the 2W measurement, detects the measurement end by using the status byte, and reads the measurement data from the 7461A. The GPIB address of the 7461A is set to 1.
Page 161
7451A/7461A/7461P Digital Multimeter Operation Manual 6.9 Sample Programs (SCPI command) Example 3 Sets the measurement function to the DCV 10 V range and performs the high-speed measure- ment (Sampling interval: 500 s). In the high-speed measurement, the data is read after the measurements of the specified count are complete.
Page 162
7451A/7461A/7461P Digital Multimeter Operation Manual 6.9 Sample Programs (SCPI command) Call ibwrt(dmm, ":DIPLAY ON" & Chr(10)) ' Sets the display to ON. Call ibonl(dmm, 0) ' Terminates. Exit Sub Else Call ibrsp(dmm, s) ' Reads the status byte. End If Call ibwrt(dmm, ":TRACE:DATA?"...
7451A/7461A/7461P Digital Multimeter Operation Manual 7. SPECIFICATIONS SPECIFICATIONS Specifications Unless otherwise specified, the measurement accuracy of this instrument is guaranteed for one year under the following conditions: Temperature; 23 5C, relative humidity; 85% or less (75% or less in a resistance measurement of larger than 10 M...
Page 164
7451A/7461A/7461P Digital Multimeter Operation Manual 7.1.1 DC Voltage Measurement (DCV) Maximum allowable applied voltage Between V and COM 1000 Vpeak Between BchHi and BchLo 200 Vpeak Between BchHi, BchLo and COM 200 Vpeak Between COM and the chassis 500 V...
7451A/7461A/7461P Digital Multimeter Operation Manual 7.1.2 AC Voltage Measurement (ACV, ACV(AC+DC)) Maximum allowable applied voltage Between V and COM 1000 Vpeak Between BchHi and BchLo 200 Vpeak Between BchHi, BchLo and COM 200 Vpeak Between COM and the chassis 500 V...
Page 166
7451A/7461A/7461P Digital Multimeter Operation Manual 7.1.2 AC Voltage Measurement (ACV, ACV(AC+DC)) ACV(AC+DC) Measurement accuracy *1 (% of reading + digits) 23C5C Input Maximum Input Range Resolution 20 Hz - 45 Hz - 100 Hz - 20 kHz - 50 kHz -...
Page 167
7451A/7461A/7461P Digital Multimeter Operation Manual 7.1.2 AC Voltage Measurement (ACV, ACV(AC+DC)) Additional error depending on the integration time AC filter: SLOW Integration time Additional error (digit) 10 s IT < 200 s In a 3 1/2-digit display 200 s IT 2 ms Includes FAST1 and FAST2.
Page 168
7451A/7461A/7461P Digital Multimeter Operation Manual 7.1.2 AC Voltage Measurement (ACV, ACV(AC+DC)) ACV(AC+DC) Measurement accuracy *1 ( of reading digits) Input Maximum Range Resolution Input impedance 20 Hz - 45 Hz - 100 Hz - 20 kHz - 50 kHz -...
7451A/7461A/7461P Digital Multimeter Operation Manual 7.1.3 Resistance Measurement (2W, LP-2W, 4W, LP-4W) 7.1.3 Resistance Measurement (2W, LP-2W, 4W, LP-4W) • 7461A/61P 2W and 4W measurements Measurement accuracy *1 Temperature coefficient *4 (% of reading + digits) (ppm of reading + digits)/C...
Page 170
7451A/7461A/7461P Digital Multimeter Operation Manual 7.1.3 Resistance Measurement (2W, LP-2W, 4W, LP-4W) Additional error depending on the integration time Additional error (digit + m) Integration time 10 s IT 200 s In a 3 1/2-digit display 2+20 200 s < IT 2 ms Includes FAST1 and FAST2.
Page 171
7451A/7461A/7461P Digital Multimeter Operation Manual 7.1.3 Resistance Measurement (2W, LP-2W, 4W, LP-4W) Low Power 2W and 4W measurements (LP-2W/LP-4W) Measurement accuracy *1 Temperature coefficient *5 (% of reading + digits) (ppm of reading + digits)/C Maximum Measurement Range Resolution display...
7451A/7461A/7461P Digital Multimeter Operation Manual 7.1.4 DC Current Measurement (DCI) 7.1.4 DC Current Measurement (DCI) • 7461A/61P Measurement accuracy *1 Temperature coefficient Resistance (% of reading + digits) (ppm of reading + digits)/C Input Maximum between Range Resolution terminal display...
7451A/7461A/7461P Digital Multimeter Operation Manual 7.1.5 AC Current Measurement (ACI, ACI(AC+DC)) Additional error depending on the integration time Integration time Additional error (digit) 100 s IT < 200 s In a 3 1/2-digit display 200 s IT 2 ms Includes FAST1 and FAST2.
Page 174
7451A/7461A/7461P Digital Multimeter Operation Manual 7.1.5 AC Current Measurement (ACI, ACI(AC+DC)) ACI(AC+DC) Measurement accuracy *1 Resistance (% of reading + digits) 23C5C Input Maximum between Range Resolution terminal display input 20 Hz - 45 Hz - 100 Hz - terminals...
Page 175
7451A/7461A/7461P Digital Multimeter Operation Manual 7.1.5 AC Current Measurement (ACI, ACI(AC+DC)) • 7451A Measurement method True RMS measurement, RMS display Input range 5% or more of full scale Crest factor 3:1 at a full scale (Except for the 3 A range) Temperature coefficient (1/10 of measurement accuracy that includes the additional error)/C in each...
7451A/7461A/7461P Digital Multimeter Operation Manual 7.1.6 Frequency Measurement (FREQ) Additional error depending on the AC filter Integration time: 10 PLC Additional error (% of reading) Frequency bandwidth Response time *1 20 Hz - 45 Hz 45 Hz - 100Hz 100 Hz - 1 kHz More than 1 kHz...
7451A/7461A/7461P Digital Multimeter Operation Manual 7.1.7 Diode Measurement Gate time Maximum display Maximum Measurement Sampling rate Gate time measurement 7461A/ frequency range 7451A period SLOW 1000 ms 1 Hz to 300 kHz 2.2 s 9999999 999999 100 ms 10 Hz to 300 kHz...
7451A/7461A/7461P Digital Multimeter Operation Manual 7.1.8 Continuity Measurement 7.1.8 Continuity Measurement • 7461A/61P Range Maximum display Resolution Measurement current 1000 1199.999 1 m 1 mA Specifications not described above are the same as those in the 1000 range in the 2W measurement.
7451A/7461A/7461P Digital Multimeter Operation Manual 7.1.10 Measurement Time and Display Digits 7.1.10 Measurement Time and Display Digits Measurement speed (In Auto-range OFF) Integration Bch-DCV Sampling rate Auto-zero 4W ACV(AC+DC) time LP-4W Continuity ACI(AC+DC) 2W Diode LP-2W FAST1 1000 times/s *1...
Page 180
7451A/7461A/7461P Digital Multimeter Operation Manual 7.1.10 Measurement Time and Display Digits Integration Time (IT) and Sampling Interval (SI) 7461A/61P 7451A Integration time (IT) Integration time (IT) Setting range Resolution Setting range Resolution 10 s to 199 s 1 s 100 s to 199 s 1 s...
7451A/7461A/7461P Digital Multimeter Operation Manual 7.1.11 Calculation Functions 7.1.11 Calculation Functions • NULL calculation Display value (NULL) = Measurement value - NULL constant • Smoothing calculation Display value (SM) = Moving average over a specified number of measurements • Comparator calculation Display (HIGH) ...
7451A/7461A/7461P Digital Multimeter Operation Manual 7.2 Interface Specifications Interface Specifications Item Specifications Remote control Remote command Compliance with SCPI and the command format for the ADC CORPO- RATION's R6552 and R64 series Interface Either GPIB or USB can be selected.
7451A/7461A/7461P Digital Multimeter Operation Manual 7.3 General Specifications General Specifications Item Specifications Operation environment Ambient temperature:0C to +50C Relative humidity: 85%RH or less no condensation 75% or less in resistance measurement of larger than 10 M and low power resistance measurement of larger than 1 M...
7451A/7461A/7461P Digital Multimeter Operation Manual 7.4 Options Options Table 7-1 Options Option Description OPT32 Changing the power supply voltage: For 120 V OPT42 Changing the power supply voltage: For 220 V OPT44 Changing the power supply voltage: For 240 V...
7451A/7461A/7461P Digital Multimeter Operation Manual 8. MAINTENANCE MAINTENANCE This chapter describes the following information which relates to the maintenance of this instrument. 8.1 Replacing Fuses 8.2 Cleaning 8.3 Calibration 8.4 Replacing Parts with Limited Life 8.5 Product Disposal and Recycle 8.6 Storage...
7451A/7461A/7461P Digital Multimeter Operation Manual 8.1.1 Replacing a Power Fuse 8.1.1 Replacing a Power Fuse The power fuse is placed in the AC power supply connector on the rear panel. For more information on how to check and replace the power fuse, refer to Section 3.4.2, “Changing the Power Supply Voltage.”...
7451A/7461A/7461P Digital Multimeter Operation Manual 8.2 Cleaning Cleaning This section describes the cleaning procedure of this instrument and warning messages. WARNING: To prevent accidents caused by electric shocks, remove all cables from this instrument. Never attempt to remove the cover to clean the inside of this instrument.
7451A/7461A/7461P Digital Multimeter Operation Manual 8.3 Calibration Calibration To maintain the measurement accuracy of this instrument, perform calibration at least once a year; warranty period. 8.3.1 Preparing for Calibration Power supply Use an AC power supply in a voltage range listed in Table 3-4 and frequency of 50 Hz or 60 Hz.
7451A/7461A/7461P Digital Multimeter Operation Manual 8.3.3 Calibration Point 8.3.3 Calibration Point Perform calibration for each range of each measurement function. For more information on relation- ships between functions and ranges, refer to Table 5-2. First, calibrate the zero point in each range calibration.
Page 190
100 k 1000 k Short 1000 k 10 M Short 10 M 100 M Short 100 M Table 8-3 Calibration Point (7451A) (1 of 2) Measurement Range Zero Calibration point1 Calibration point2 Calibration point3 function 300 mV Short +300 mV...
Page 191
7451A/7461A/7461P Digital Multimeter Operation Manual 8.3.3 Calibration Point Table 8-3 Calibration Point (7451A) (2 of 2) Measurement Range Zero Calibration point1 Calibration point2 Calibration point3 function 3000 A +3000 A Open 30 mA Open +30 mA 300 mA Open +300 mA...
7451A/7461A/7461P Digital Multimeter Operation Manual 8.3.4 Calibration Procedure 8.3.4 Calibration Procedure Perform calibration in following procedure. Set the calibration mode. Short-circuit all input terminals on the rear panel. Select the input terminal on the front panel. Short-circuit the V, COM, HI, and LO terminals and then open the mA termi- nal.
Page 193
7451A/7461A/7461P Digital Multimeter Operation Manual 8.3.4 Calibration Procedure Set a range to be calibrated. Pressing the HOLD key displays the measurement value as a setting value. 10. Adjust the setting value to the calibration value by using the keys. EXIT...
Page 194
7451A/7461A/7461P Digital Multimeter Operation Manual 8.3.4 Calibration Procedure 22. Press the ENTER key to start the calibration. 23. Return to step 21 after displaying “PASS” or “FAIL” If “PASS” is displayed, press the EXIT key to exit. If “FAIL” is displayed, restart the calibration after checking that all input termi- nals on the rear panel are short-circuited.
7451A/7461A/7461P Digital Multimeter Operation Manual 8.4 Replacing Parts with Limited Life Replacing Parts with Limited Life Parts with limited life used in this instrument are listed in the following table. Contact an ADC CORPORATION sales representative to replace any parts, referring to the limited lives listed in the following table.
7451A/7461A/7461P Digital Multimeter Operation Manual 8.5 Product Disposal and Recycle Product Disposal and Recycle This product should be disposed of according to the regulations and laws that are established by your country and municipality. When treating this product, separately collect components according to this section to prevent the spread of substances, which may be harmful to humans, and to protect the global environment.
Page 197
7451A/7461A/7461P Digital Multimeter Operation Manual 8.5 Product Disposal and Recycle Table 8-5 Disposal (2 of 2) Quantity in Used/ Substance/Component Location Unit Component maximum Not used configuration External electric cables Used Main frame Accessories Power cable Input cable Components containing...
7451A/7461A/7461P Digital Multimeter Operation Manual 8.6 Storage Storage If not using this instrument for a long time, put it in a carton case and store it in an area away from dust and direct sunlight. Storage temperature: -25C to +70C...
7451A/7461A/7461P Digital Multimeter Operation Manual 8.9 System Recovery Procedure System Recovery Procedure Initialization The following shows how to initialize the setting parameters. 6 INIT Select from the mode and press to enter the selection MENU layer. The ‘Param’ parameter is displayed. Press to enter the entry layer.
Page 200
7451A/7461A/7461P Digital Multimeter Operation Manual 8.9 System Recovery Procedure Table 8-6 Initial Values of Setting Parameters (1 of 3) Selecting ‘LOAD’ in 5PARAM Selecting When DFLT from Parameter P.OFF from *RST *CLS shipping 6INIT in DFLT USER setting ‘PON.LD’ MENU...
Page 201
7451A/7461A/7461P Digital Multimeter Operation Manual 8.9 System Recovery Procedure Table 8-6 Initial Values of Setting Parameters (2 of 3) Selecting ‘LOAD’ in 5PARAM Selecting When DFLT from Parameter P.OFF from *RST *CLS shipping 6INIT in DFLT USER setting ‘PON.LD’ MENU...
Page 202
7451A/7461A/7461P Digital Multimeter Operation Manual 8.9 System Recovery Procedure Table 8-6 Initial Values of Setting Parameters (3 of 3) Selecting ‘LOAD’ in 5PARAM Selecting When DFLT from Parameter P.OFF from *RST *CLS shipping 6INIT in DFLT USER setting ‘PON.LD’ MENU...
7451A/7461A/7461P Digital Multimeter Operation Manual 8.10 Self-Test 8.10 Self-Test 8.10.1 Self-Test The self-test can be performed from the panel operations or by executing the remote command. The self-test is performed by selecting ‘TEST’ from or executing the *TST? 9 SYS MENU remote command.
Page 204
7451A/7461A/7461P Digital Multimeter Operation Manual 8.10.2 Display and Key Tests Operations Display Select ‘P/KEY’ by using P/KEY P/KEY Press ENTER All segments Press ENTER of the display are turned on. The display changes after a few seconds. Push Press a key to be checked.
7451A/7461A/7461P Digital Multimeter Operation Manual 8.11 Error Message List 8.11 Error Message List This section describes the error number and how to deal with error displayed on this instrument. Error description Error display Solution [ ]: Response to the ERR? command...
Page 206
7451A/7461A/7461P Digital Multimeter Operation Manual 8.11 Error Message List Error description Error display Solution [ ]: Response to the ERR? command Err208 LV100 zero measurement test error in analog operation No solution [LV 100 Zero Check] Err210 Communication error in Analog...
Page 207
7451A/7461A/7461P Digital Multimeter Operation Manual 8.11 Error Message List Error description Error display Solution [ ]: Response to the ERR? command Err-200 Execution error (Command which cannot be executed now) Solution7 [Execution error] Err-213 The INITiate command is ignored because the measurement Solution7 is performing.
ALPHABETICAL INDEX ALPHABETICAL INDEX 7451A/7461A/7461P Digital Multimeter Operation Manual ALPHABETICAL INDEX Display Digit Setting ......5-14 Display Mode Setting ......5-14 AC Current Measurement Display Section ........4-2 (ACI, ACI(AC+DC)) ......7-11 AC Voltage Measurement (ACV, ACV(AC+DC)) ......7-3 Accessories ..........3-5 Electromagnetic Interference ....
Page 212
7451A/7461A/7461P Digital Multimeter Operation Manual Alphabetical Index Measurement Functions and Parameters 5-9 Response to the *IDN? Command Measurement Range and Auto-Range ..5-11 (7451A/61A Only) ........6-1 Measurement Range Selection Keys ..4-3 Measurement Time and Display Digits .. 7-17 Memory Clear .........