Sharp AR-SS2 Service Manual page 30

20-bin staple sorter
Table of Contents

Advertisement

AR-SS2
C. Stapler unit drive system
(1) Outline
The stapler unit staples paper discharged into the bins.
The stapling is driven by the stapler motor (M5).
The stapler unit oscillation is performed by the stapler unit oscillation
motor (M4).
The stapler unit home position is detected by the stapler unit oscilla-
tion home position switch (MS4) and the stepping motor is driven by
the specified number of pulses to move the stapler unit to the oscilla-
tion position.
During oscillation, the stapler presses the paper holding lever to hold
paper during stapling.
PI9
PI8
MS3
Stapler motor
Staple empty detection signal
Cartridge empty detection signal
MS5
MS6
Stapler operation home
position detection signal
Staple cue detection signal
Stapler unit oscillation home
position detection signal
MS4
Stapler safety detection signal
Stapler unit oscillation motor
drive signal
M4
Stapler motor
drive signal
M5