H1/6 BLUE (-) multiplex input, zone 4
Inputs shorter than 0.8 seconds will trigger the warning response, while inputs longer than 0.8
seconds will trigger the full alarm sequence. If installing an optional dual-stage sensor, connect both
the blue and the green wires of the optional sensor to this input. This wire will report Zone 4.
H1/7 VIOLET (+) door trigger input, zone 3
This type of dome circuit is used in many Ford products. Connect the VIOLET wire to a wire that
shows (+)12V when any door is opened. This wire will report Zone 3.
NOTE: If using a door trigger wire that has a delay, Advanced Menu 2, feature 6, or the Pro Security
Programmer can be used to turn open zone notification off.
H1/8 BLACK (-) Chassis Ground Connection
Connect this wire to a clean, paint-free sheet metal location (driver kick panel) using a factory bolt
that DOES NOT have any vehicle component grounds attached to it. A screw should only be used
when in conjunction with a two-sided lock washer. Under dash brackets and door sheet metal are
not acceptable ground points. It is recommended that all security components be grounded at the
same location.