Page 2
Citel Technologies does not warrant that this product is immune from or will prevent unauthorized use of common-carrier telecommunications services or facilities accessed through or connected to it.
Failure to follow the instructions may result in improperly installed equipment or risk of electrical shock. Changes or modifications not expressly approved by Citel Technologies could void the user’s authority to operate the equipment and will impact any warranty agreements.
If a user dials emergency services from the remote location when connected to the Remote Module and linked to the Switch Module they will reach the emergency facility that serves the location of the PBX and not the location of the Remote Module.
5. Connect the supplied RJ-11 to RJ11 cable between the analog line provided by the PSTN to the Telco port on the rear of the Switch Module. Do not apply power to the unit until instructed to do so. An improperly configured Remote can cause damage to the unit or to the telephone sets.
6. Manually enter the Connect Rate (default is Auto) 7. Enable or disable Pulse Dialing depending on the analog line service 8. Enable or disable Dialback – the Dialback feature is used for the Switch to automatically call back the remote during a connection attempt 9.
EXTender 1100A Remote Module: Quick Installation Guide Citel’s multi-user PBXgateways (refer the System Administrator’s Guide for more details). 10. IP Parameters (or DHCP): a) IP Address b) Subnet Mask c) Default Router 11. When complete the administrator is prompted to save the changes and reboot.
Line disabled) is the default setting. Essential Connect Parameters – Dial Numbers The Dial Numbers are used to connect to the Switch Module from the Remote Module over the PSTN via the internal modem. They are only required if Leased Line mode is disabled (in dial-up mode).
Switch you require a User ID. The default ID is 1 (representing the port number). This feature is also typically used when connecting to one of Citel’s multi-user devices such as a PBXgateway. If this remote is connecting to a multi-user device refer to the System Administrator’s Guide of the...
Confirm that the phone rings and that the voice path is established. 4. Make the necessary changes to the Dialback numbers if required. Reconnect the analog lines to the Switch and Remote Modules and attempt to connect. If problems persist refer to the Trouble Shooting section in the System Administrator’s Guide.
5. If you Press 2 (Ok) a “Discon Sequence” message will be displayed on the LCD and then Remote LCD should return to the “Connect, Press 1” menu. The Remote module is now no longer connected to the Switch module, the Extender Session is disconnected.
Remote User ID, if not configured you will be prompted to enter User ID on each connect to Switch Module. The default User ID is 1 on Switch side. See the Remote Module Advanced Port Setup in the System Administrator’s Guide for full details.
Page 24
Administrator’s Guide for full details. Path: Remote->Configuration->System 14. Setup the Remote Module to use the time stamp from the Switch Module for trouble shooting purposes. See the Remote Module Advanced System Parameters – System Settings section in the System Administrator’s Guide for full details.
Electricity at Work Regulations 1989 This product, as manufactured by Citel Technologies Limited, is a SYSTEM as defined by the Electricity At Work Regulations 1989. All persons involved in the installation and repair should be aware of their duties and responsibilities under these regulations.