Fig.30
System
Fig.31
Maximum accumulator temperature
Fig.32
Connection temperature
Fig.33
Shutdown temperature
Fig.34
Confirmation
7729335 - 04 - 12052021
System
Select the solar system required.
SIST
SET
1
Maximum accumulator temperature
Adjust the desired maximum temperature of the accumulator.
AMAX
SET
9O
o
C
Connection temperature for the auxiliary heating
Set the required connection temperature.
CA1O
SET
4O
o
C
Shutdown temperature for the auxiliary heating
Set the required shutdown temperature.
CA1F
SET
45
o
C
Finalising settings in the commissioning menu
After accessing the last channel in the commissioning menu, a safety
request is displayed to confirm the settings made. To confirm the settings
made, press the central key.
OK
SET
PUSH
9.3.2
Tab.16
Channel
SIST
DT O
DT F
DT N
A MX
AUM
CSEG
ORC
OMNC
OAH
OCT
Factory setting values
Factory values
Meaning
System
Difference in connection temperature
Difference in shutdown temperature
Difference in nominal temperature
Maximum accumulator temperature
Increase
Collector temperature limit
Collector cooling option
Minimum threshold collector option
Antifreeze option
Vacuum tube collector option
9 Commissioning
Factory set­
ting
1
6.0 K
4.0 K
10.0 K
60 ºC
2 k
130 ºC
OFF
OFF
OFF
OFF
Solar hydraulic unit
33