Description of the solar control on the SH 7 Compact Top
Fig.24
26
Solar hydraulic unit
Operating status indication
Rapid heating is not possible because the shutdown temperature has been exceeded
Maximum accumulator threshold on (the temperature of the accumulator has exceeded the maxi
mum value)
Collector cooling function, system cooling function or accumulator cooling function active
Antifreeze option activated
Minimum threshold collector on, antifreeze function active
Collector safety disconnection activated
Sensor error
Accumulator safety disconnection activated
Parameter
Setting mode
7.2.1
The controller is operated using the 2 keys and the dial located under the
screen:
Briefly press the manual mode key to access the manual mode menu.
The holiday mode key is used to activate the holiday mode. Pressing and
holding this key down for approx. 3 seconds displays the Holiday Days
setting where you can set the holiday duration in days. If you set a value
above 0, the set function in the Holiday mode menu will be activated and a
countdown of the remaining days will be displayed from midnight. If this
value is set to 0, the function remains deactivated.
BA-0000087-01
7.2.2
The control features a control indicator with various colours in the centre of
the dial. This indicates the following operating statuses:
Keys and dial
1 Return to the previous menu
2 Confirm/select
3 Move up/down, increase/reduce values
4 Manual mode
5 Holiday mode
Control indicator
7729335 - 04 - 12052021