Baxi SH 7 COMPACT Installation And Service Manual page 29

Solar hydraulic unit
Table of Contents

Advertisement

8.3
Pump technical data
7729335 - 04 - 12052021
Tab.11
Sequence of error alarms
LED
LED
LED
LED
1
2
3
4
x
x
x
x
x
When there are no active alarms, the operation panel returns to
operational mode.
It works with an external solar profile PWM C or in internal control with
constant curve.
Tab.12
Operating status
LED 1
(green)
CC1
CC2
CC3
PWM C shutdown
signal
PWM C start-up
signal
(*) 1 flash per second
(**) 2 flashes per second
Tab.13
Technical data
UPM3 15-75
Pressure system
Max. 1.0 MPa (10 bar)
Minimum input pressu­
0.05 MPa (0.50 bar) at
re
95 °C of fluid tempera­
ture
Fluid temperature
2-110 °C (TF110) Max.
130 °C (60 °C ambient
temperature)
IP class
IPX4D
Motor protection
No external protection
necessary
LED
Pump ope­
Indications
5
ration
Attempt res­
Rotor blo­
tart every
x
cked
1.33 se­
conds
Warning
Voltage
only, pumps
supplied too
continues to
low
run
The pump
has stopped
running be­
Electrical
cause the
fault
voltage sup­
plied is low,
or there is a
serious fault
LED 2
LED 3
(green)
(yellow)
x
x
x
x *
x
x**
x
UPM3 15-145
Max. 1.0 MPa (10 bar)
0.05 MPa (0.50 bar) at
95 °C of fluid tempera­
ture
2-110 °C (TF110) Max.
130 °C (60 °C ambient
temperature)
IPX4D
No external protection
necessary
Solar hydraulic unit
8 Solar pump
Action
Wait and
unblock the
shaft
Check the
voltage sup­
plied
Check the
voltage sup­
plied. Re­
place the
pump
LED 4
LED 5
(yellow)
(yellow)
x
x
x
x
x
x
x
29

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sh 7 compact topSh 7Sh 14Sh 7 simple