8.3
Pump technical data
7729335 - 04 - 12052021
Tab.11
Sequence of error alarms
LED
LED
LED
LED
1
2
3
4
x
x
x
x
x
When there are no active alarms, the operation panel returns to
operational mode.
It works with an external solar profile PWM C or in internal control with
constant curve.
Tab.12
Operating status
LED 1
(green)
CC1
CC2
CC3
PWM C shutdown
signal
PWM C start-up
signal
(*) 1 flash per second
(**) 2 flashes per second
Tab.13
Technical data
UPM3 15-75
Pressure system
Max. 1.0 MPa (10 bar)
Minimum input pressu
0.05 MPa (0.50 bar) at
re
95 °C of fluid tempera
ture
Fluid temperature
2-110 °C (TF110) Max.
130 °C (60 °C ambient
temperature)
IP class
IPX4D
Motor protection
No external protection
necessary
LED
Pump ope
Indications
5
ration
Attempt res
Rotor blo
tart every
x
cked
1.33 se
conds
Warning
Voltage
only, pumps
supplied too
continues to
low
run
The pump
has stopped
running be
Electrical
cause the
fault
voltage sup
plied is low,
or there is a
serious fault
LED 2
LED 3
(green)
(yellow)
x
x
x
x *
x
x**
x
UPM3 15-145
Max. 1.0 MPa (10 bar)
0.05 MPa (0.50 bar) at
95 °C of fluid tempera
ture
2-110 °C (TF110) Max.
130 °C (60 °C ambient
temperature)
IPX4D
No external protection
necessary
Solar hydraulic unit
8 Solar pump
Action
Wait and
unblock the
shaft
Check the
voltage sup
plied
Check the
voltage sup
plied. Re
place the
pump
LED 4
LED 5
(yellow)
(yellow)
x
x
x
x
x
x
x
29