Chapter 8
Cisco ASR 1002 Router Overview and Installation
Figure 8-34
1
Positive lead wire
2
Negative lead wire
Note
When securing the ground, positive, and negative +24 VDC-input leads to the power supply faceplate,
Caution
leave extra service loop in the ground (GND) lead to ensure that the ground lead is the last lead wire to
disconnect from the power supply if a great deal of strain is placed on all three leads.
OL-13208-09
Cisco +24 VDC Power Supply Terminal Block With Lead Wires Installed
O U T P U
T IN P U
F A IL
T h is u n
it m ig h t
o n e p o w
e r su p p
A ll co n n
e ct io n s
to d e -e n
e rg iz e th
+ 2 7 V D
+ 2 7 V
1
2
3
Make sure the stripped end of each lead wire is twisted tightly together. This makes insertion
easier. Then make certain the entire lead wire is inserted all the way into its receptacle. If any
exposed wire at the stripped end of a lead is visible after inserting the lead into its receptacle,
remove the lead from the receptacle, use the wire stripper to cut the stripped end of the lead, and
then reinsert.
Cisco ASR 1000 Series Aggregation Services Routers Hardware Installation Guide
T
F A N
O K
O K
h a ve m
o re th a n
ly co n n
e ct io n .
m u st b e
re m o ve
d
e u n it.
C IN P U
T
3 2 A
3
Ground lead wire
— —