Advertisement

Quick Links

Installation and Operating Manual
UK
BWT PERMAQ
Compact CRU
www.bwt-group.com

Advertisement

Table of Contents
loading

Summary of Contents for BWT PERMAQ Compact CRU

  • Page 1 Installation and Operating Manual BWT PERMAQ Compact CRU www.bwt-group.com...
  • Page 3: Table Of Contents

    EXPLANATION OF WORDS FUNCTIONAL DESCRIPTION INSTALLATION OF BWT PERMAQ COMPACT CRU 4.1. Positioning 4.2. Water connections 4.3. Electric installation START AND OPERATION OF BWT PERMAQ COMPACT CRU TECHNICAL SPECIFICATIONS AND SETTINGS SURVEY OF ALARM CONDITIONS SETTINGS TROUBLE SHOOTING ANNEX 9.1. Technical specifications 9.2.
  • Page 4: General Information

    Permeate: The treated, totally desalinated water which is produced by the RO-plant and supplied to the reservoir tank. Concentrate: Is the water that is led to outlet or to BWT PERMAQ Compact CRU. This wa- ter contains the salts and minerals that have been removed from the raw water.
  • Page 5: Installation Of Bwt Permaq Compact Cru

    4.1. Positioning The BWT PERMAQ Compact CRU must be placed in frost-free surroundings on a level foun- dation. The foundation shall be able to carry a weight load of 130 kg. The weight load of any other plants should also be taken into account! Important! There must be free space at either side of the unit for water installations.
  • Page 6: Electric Installation

    Make sure that the overflow branch is connected to the drain and there is concen- trate flow (max. 500l/h) from BWT RO plant in to the BWT PERMAQ Compact CRU Power ON the BWT PERMAQ Compact CRU and check that the transport pump mo- tor is running.
  • Page 7: Technical Specifications And Settings

    It is possible to change the various time settings for Start, Stop and Alarm, plus delayed start- up of pumps. Use of DIP-switch: No. 1 (Only available for PERMAQ COMPACT 41) No. 2 Transport pump No. 3 Selection of BWT PERMAQ Compact CRU model No. 4-6 Transport pump...
  • Page 8: Survey Of Alarm Conditions Settings

    7. SURVEY OF ALARM CONDITIONS SETTINGS LED function: In normal operation the LED’s are lit corresponding to the components they rep- resent. Fault conditions are described in Chapter 8. Trouble shooting “Re-start ALARM” on TP-pump: (Nothing is working – See: Fault 4 permanent condition) ALARM - Too high water level: (Nothing is working –...
  • Page 9: Trouble Shooting

    Reason for fault Action fault  Check that the RO-plant is running and there is flow of concentrate to the BWT PERMAQ Compact CRU. The RO-plant may produce less concentrate than there is need of for con- sumption.  Check if too many consumers are connected...
  • Page 10 2.7 bar. stops  The hydrophore capacity is too  Contact BWT for technical advice. small.  Set the pressure switch at 4.0 bar (Stop) and  Pressure switch set incorrectly. 3.0 bar (Start).
  • Page 11: Annex

    9. ANNEX 9.1. Technical specifications BWT PERMAQ Compact CRU Designation Type/data number Tank volume 100 l Max. concentrate flow to the CRU 500 l/h Transport pump 0.85 kW, 4.5A Pump capacity 3 bar / 3 m Height/Width/Depth 810/580/630 mm Concentrate inlet, diameter...
  • Page 12: P&I Diagram Bwt Permaq Compact Cru

    9.2. P&I Diagram BWT PERMAQ Compact CRU...
  • Page 13: Layout

    9.3. Layout...
  • Page 14: Electrical Connections

    9.4. Electrical connections...
  • Page 15: Pcb - Circuit Board

    9.5. PCB – circuit board...
  • Page 16: Start-Up Test

    NO, the problem does not concerns the plant or the installation The plant - we mean only the part of the whole installation which was delivered by BWT (i.e only the plant). The installation - we mean the piping etc. leading to the plant.
  • Page 17: Spare Parts List Bwt Permaq Compact Cru

    200729004 Solenoid valve ½” 200753004 Control box complete 20 µF Capacitor (Transport 750001270 pump motor) Cable for level switch 451404470 10 mm plastic hose 454001010 3 years * Contact your local BWT dealer for detailed information. 9.8. Spare parts overview...
  • Page 18: Disposal

    EU legislation in Member States requires electrical and electronic equipment to be collected separately from unsorted municipal waste so that it may be recycled. In Denmark and several other countries, BWT itself assumes responsibility for the return and conformant disposal of its electronic and electrical products. These products may not be placed with household waste or brought to collection centres run by local public disposal operations –...
  • Page 19: Declaration Of Conformity

    +45 43 600 500 - fax: +45 43 600 900 bwt@bwt.dk - www.bwt.dk herewith declares that: BWT PERMAQ Compact CRU is in conformity with the provisions of the Machinery Directive (directive 2006/42/EC) is in conformity with the provisions of the following other EC directives...
  • Page 20 Fax: +33 1 4922 45 45 E-Mail: office@bwt.at E-Mail: bwt@bwt.de E-Mail: info@cillichemie.com E-Mail: bwt@bwt.fr BWT Belgium NM. BWE Česká Republika s.r.o. BWT Polska Sp. z o.o. BWT Hungária Kft. Leuvensesteenweg 633 Lipovo 196 -Cestlice ul. Polczyhska 116 Keleti út. 7. B-1930 Zaventem CZ-251 01 Říčany...