Select Proofer Model Via Bootloader - baxter PW1E Operator's Manual

Table of Contents

Advertisement

Setup Hints
During Rest Period, the unit does not heat, cool or circulate air; this allows the dough to rest.
During Recovery Time, the unit slowly heats up and adds humidity, bringing the unit to the preset
temperature and humidity and into the proof stage of the automatic retard/proof process.

SELECT PROOFER MODEL VIA BOOTLOADER

The proofer model is set at the factory. However, if the proofer model needs to be changed this procedure
shall be followed.
1. Turn off the Proofer with the ON/OFF button.
2. Hold these three buttons, in this order for 5 seconds.
HUMIDITY DOWN ARROW
TEMPERATURE UP ARROW
ON/OFF Button.
3. Keep holding the three buttons until "conF" is shown in the Temperature display (Fig. 23).
4. The current proofer configuration value will be displayed in the HUMIDITY display. 1, 2 or 3
5. Pressing the HUMIDITY UP ARROW will cycle through the configurations, 1, 2 or 3
Config 1: Proofer (PW)
Config 2: Retarder/Proofer (RPW)
Config 3: Dehumidifying Proofer (DPC1S)
6. The configuration is saved by pressing the ON/OFF button.
7. The TEMP and HUMIDITY display LEDs will flash on and off for two seconds to indicate that the
new configuration has been saved.
8. The proofer control board will reboot with the new configuration.
NOTE: If the application firmware is corrupt or missing, the unit will enter the bootloader automatically.
This will happen even if you do select a proofer model, it will still return to the bootloader where you are
required to load the firmware. To correct this error, update the proofer firmware.