CUSTOMIZED OPERATION

The Proofer and the Retarder/Proofer controls have the capability of being customized to fit your own
personal needs using the setup mode.
NOTE: Before entering the setup mode, read all the instructions to make sure you are completely clear
on what to do. If you need assistance, please call your authorized service office.
Entering Setup Mode
1. Press and hold the TIMER NUMBER arrow button.
While pressing the TIMER NUMBER arrow button,
press the ON/OFF button (Fig. 22).
2. A "0" will appear in the TIMER NUMBER display.
3. Release both buttons.
4. You are now in setup mode.
Changing Items in Setup Mode
1. The number in the TIMER NUMBER display is the setup number. The other display windows will
light up, depending on what item is being changed.
2. To change the setup item being displayed, go to that display and use the arrow buttons to the left of
the display to adjust the setting.
3. To change the setup number, press the UP or DOWN arrow to the left of the TIMERS display.
4. To exit the setup mode, press the ON/OFF and TIMER NUMBER arrow button once to get back to
normal operation.
NOTE: There may be setup numbers in the setup mode that do not pertain to your particular proofer. Do
not attempt to set these. Skip them and go to the next appropriate number.
Setup Guide
Setup Number
1
2
3
4
5
6
7
9
10
11
12
13
14
15
16
17
Degrees Fahrenheit
Temperature Offset (0= -15°F/C, 15= 0°F/C, 30= +15°F/C)
Humidity Offset (0= -15%RH, 15= 0%RH, 30= +15%RH)
Minimum proof temperature that can be set
Maximum proof temperature that can be set
Minimum proof humidity that can be set
Maximum proof humidity that can be set
Preheat Disabled (1=Disabled, 0=Enabled) (PW only)
Minimum retard temperature that can be set (RPW only)
Maximum retard temperature that can be set (RPW only)
Rest period (RPW only)
Recovery period (RPW only)
Military or standard time (RPW only)
Daily/Weekly (1= 7 Day Cycle, 0= 1 Day Cycle)
Defrost Refrigeration equipment every xx hours (Max. 10 hours)
Defrost Refrigeration equipment for xx minutes (Max. 60 minutes)
ON
OFF
Setup Item
– 16 –
TEMP
ON
%HUMIDITY
ON
TIMER
START
NUMBER
ON
STOP
TIMERS
Fig. 22