Liberty Pumps Pro370 Series Installation Manual

Liberty Pumps Pro370 Series Installation Manual

Vertical discharge 21”d x 30”h/24”d x 24”h/24”d x 36”h 41 gallon system
Hide thumbs Also See for Pro370 Series:

Advertisement

Quick Links

Installation Manual
Simplex Sewage/Grinder Systems
Models
Pro370-Series
Sewage System
Vertical Discharge
21"D x 30"H
41 Gallon System
Indoor and Outdoor*
Installation
* with optional Access Riser
7000 Apple Tree Avenue
Bergen, NY 14416
ph: 800-543-2550
fax: 585-494-1839
www.LibertyPumps.com
Pro380-Series
Sewage System
ProVore®380-Series
Grinder System
Vertical Discharge
24"D x 24"H
41 Gallon System
Indoor and Outdoor*
Installation
Copyright © Liberty Pumps, Inc. 2020 All rights reserved.
Pro380-SD-Series
Sewage System
ProVore®380-SD-
Series Grinder
System
Side Discharge
24"D x 24"H
41 Gallon System
Indoor and Outdoor
Installation
7225000J
700-Series
Sewage System
ProVore®700-Series
Grinder System
Vertical Discharge
24"D x 36"H
70 Gallon System
Indoor Installation
Only

Advertisement

loading
Need help?

Need help?

Do you have a question about the Pro370 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Liberty Pumps Pro370 Series

  • Page 1 Indoor and Outdoor* Indoor and Outdoor* Indoor and Outdoor Indoor Installation Installation Installation Installation Only * with optional Access Riser 7000 Apple Tree Avenue Bergen, NY 14416 ph: 800-543-2550 fax: 585-494-1839 www.LibertyPumps.com Copyright © Liberty Pumps, Inc. 2020 All rights reserved.
  • Page 2 Keep this manual handy for future reference. Pump Serial #: For replacement manual, visit LibertyPumps.com, or contact Liberty Pumps at System #: 800-543-2550. Manufacture Date: Retain dated sales receipt for warranty. Install Date: 2 | EN Copyright © Liberty Pumps, Inc. 2020 All rights reserved. 7225000J...
  • Page 3  Do not remove any tags or labels from the pump or its cord.  Keep clear of suction and discharge openings. To prevent injury, never insert fingers into pump while it is connected to a power source. 7225000J Copyright © Liberty Pumps, Inc. 2020 All rights reserved. 3 | EN...
  • Page 4  Do not use pumps with fluid over 140°F (60°C). Operating the not be achieved for proper operation. Discharge sizes may be pump in fluid above this temperature can overheat the pump, reduced to 1-1/4”. Consult Liberty Pumps for proper pipe and resulting in pump failure. system sizing.
  • Page 5 36- / ” [7.6cm] [93cm] 24- / ” [62.5cm] 24-³/ ” [61.9cm] Figure 2. 380-Series Vertical Discharge Basin Dimensions 22- / ” [57.2cm] Figure 4. 700-Series Basin Dimensions 7225000J Copyright © Liberty Pumps, Inc. 2020 All rights reserved. 5 | EN...
  • Page 6 4” seal for inlet connection. Connect the gravity drainage line from the fixtures to this hub. Discharge 2” PVC Cord Exit Figure 7. 380-Series Side Discharge Cover 6 | EN Copyright © Liberty Pumps, Inc. 2020 All rights reserved. 7225000J...
  • Page 7 Larger pipe sizes may be required to eliminate friction backfill material as this could cause the tank to collapse. head loss over long runs. Contact Liberty Pumps or other qualified person if there are questions regarding proper pipe size and flow Installation rates.
  • Page 8 Figure 13 [left], being directly, bypassing the switch and using the circuit breaker or careful to remove excessive cord “slack” from inside the system. panel disconnect to operate the pump. 8 | EN Copyright © Liberty Pumps, Inc. 2020 All rights reserved. 7225000J...
  • Page 9 Contact Liberty FLOAT Pumps customer service for the proper cover for the application. TETHER LENGTH Not to scale Figure 14. QuickTree Example Settings 7225000J Copyright © Liberty Pumps, Inc. 2020 All rights reserved. 9 | EN...
  • Page 10 Tighten the bolts furthest away from the power cord grooves first, Liberty Pumps, Inc. shall not be liable for any loss, damage, or torquing to 40 inch-pounds. Do not overtighten bolts. The expenses resulting from installation or use of its products, or for...