Checking The Usage - Honeywell ECOMAX Operating Instructions Manual

Self-recuperative burner
Hide thumbs Also See for ECOMAX:
Table of Contents

Advertisement

Checking the usage

Intended use
Self-recuperative burner ECOMAX
grated recuperator for the direct and indirect heating
of furnace systems in intermittent mode.
Direct heating
Flue gases are returned using an eductor.
Indirect heating
Combustion flue gases are separated from the prod-
uct using metallic or ceramic radiant tubes and ce-
ramic segmented flame tubes.
This function is only guaranteed when used within the
specified limits – see page 18 (Technical data). Any
other use is considered as non-compliant.
Type code
Code
ECOMAX
®
Self-recuperative burner for gas
0 to 6
C
Ceramic burled tube recuperator
M
Cast steel ribbed tube recuperator
P
Cast steel ribbed tube recuperator for
F
Flat tube recuperator, metallic
395 to
695
-S
-M
1)
B
D
G
L
1)
/D-
For direct heating with eductor
/R-
For radiant tube heating without eductor
/V-
For radiant tube heating with VAH
/E-
Burner with customized orifices
/nnn-
Burner construction stage X for nnn kW
/N-
(1 to 99)
X, A, B ...
The following features differ from the
Additional cooling air connection for
K
A
Electrode made of Kanthal APM
T
S
W
Air connection without intermediate flange
Z
1) On request.
2) Other gas types on request.
®
for gas with inte-
Description
Burner size
(SiSiC)
P radiant tube
Recuperator length in mm
Standard flame
menox low NO
operation
X
Gas type
natural gas
coke oven gas
LPG
LCV gas
Burner without orifices
Burner head identifier
Construction stage
standard version:
increased furnace cooling
NPT connections
SICAFLEX spacer
Special version
Part designations
ECOMAX
®
direct
2
4
3
2
1
9
8
11
Gas insert
Gaskets (set)
Intermediate flange
4
LFR unit (air guide tube)
5
Body with internal insulation
6
Eductor EJEK (to be ordered separately)
7
Recuperator
8
Gas flange set
9
Type label
0
Air flange set

Intermediate flange

Enclosed documentation (flow rate curves, op-
erating characteristic diagrams, spare parts list,
spare parts drawing)
2)
:
ECOMAX
®
indirect
2
4
2
1
9
8
11
Gas insert
Gaskets (set)
4
LFR unit (air guide tube)
5
Body with internal insulation
6
Flue gas connector FLUP (to be ordered sepa-
rately)
7
Recuperator
8
Gas flange set
9
Type label
0
Air flange set

Intermediate flange

Enclosed documentation (flow rate curves, op-
erating characteristic diagrams, spare parts list,
spare parts drawing)
GB-2
6
7
5
10
12
6
7
5
12
10

Advertisement

Table of Contents
loading

This manual is also suitable for:

03251385

Table of Contents