SCTE-104 Trigger Insertion (SCTE-104 Module)

The SCTE-104 module inserts SCTE-104 packets on a user-configurable VANC line, using the 4107 DID/SDID (as per
SMPTE 2010).
To determine if SCTE104 Trigger Insertion is installed on your unit, access your encoder's web interface, look for
an entry that says SCTE104 Trigger Insertion on the left side menu and select it. If you are prompted for a license
key, the feature is not installed and can be purchased by contacting the EEG sales team.
SCTE-104 messages can either be authored using a built-in preset editor and triggered via GPI (see Figure 13), or
can be sent from an external source using the SCTE-104 network protocol over TCP/IP.
Further documentation for this feature may be found at
https://eegent.com/support/resources
Figure 16: SCTE-104 Settings on the Web Interface