Section 4C. Status Leds - Nabco Magnum 4A Control Wiring And Adjustment Manual

Swing door operator
Table of Contents

Advertisement

Magnum 4A Control Wiring & Adjustment Manual
Part #15-10682
Section 4c. Status LEDs
(2) LED Indicators are used to display what the Magnum 4A Control is reacting to at any instant
within the Swing door cycle. This helps to identify when the Swing door system is functioning
properly. Please see Figure 4-4.
Table 4-3 Status LED Indicators
Green
Cycle
Indicates door position during an open and closed cycle.
LED
Status
Fast Flashing
On Solid
Slow Flashing
Off
Red
Safety
Indicates state of the (2) Safety Signals, or the state of the Current Limit at any instant during the
Swing door cycle.
Slow Flashing
Fast Flashing
On Solid
4-16
Red LED
F1
AUX
Fuse 1: 0.5A 24 VAC
PWR
J2
TRANSFORMER
DN 0558
Indicator
(2 flashes per second)
(1 flash per second)
Indicator
(1 flashes per second)
(2 flashes per second)
STOP
BCHK
TDPG
CLOSE
OPEN
TDAS
LCHK
LED
SIGNAL
INPUT
J1
Description
Door is opening.
Door is in Back Check.
Door is closing.
Door is in Latch Check or Closed
Door mounted Sensor on Swing side of door is activated.
Continuous Safety.
X
Header Mounted Sensor on Swing side of door is
X
activated.
X
Safety with Lockout.
Current Limit is activated.
X
X
www.NabcoEntrances.com
Green LED
Figure 4-4 LED Indicators