INSTALLATION INSTRUCTIONS
FOR
6633 SERIES
PACKAGE AIR CONDITIONER
INSTRUCTIONS D'INSTALLATION
DES CLIMATISEURS MONOBLOCS
SÉRIE 6633
RV Products
A Division of Airxcel, Inc.
P.O. Box 4020
Wichita, KS 67204
1976C285 (4-06) PP

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RVP 6633 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Airxcel RVP 6633 Series

  • Page 1 INSTALLATION INSTRUCTIONS 6633 SERIES PACKAGE AIR CONDITIONER INSTRUCTIONS D’INSTALLATION DES CLIMATISEURS MONOBLOCS SÉRIE 6633 RV Products A Division of Airxcel, Inc. P.O. Box 4020 Wichita, KS 67204 1976C285 (4-06) PP...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Warnings ............Component Match-Up .
  • Page 3: Unit Depiction Figures

    3. UNIT DEPICTION FIGURES FIGURE 1 FIGURE 2...
  • Page 4: General Information

    4. GENERAL INFORMATION The 6633 series package air conditioners are intended only for Conditioned air is delivered from the air conditioner to the installation by home manufacturers. The units are for “off the interior of the vehicle through ducting that is supplied and roof”...
  • Page 5: Duct And Register Specifications

    When pad mounting, the unit should be with a trap to insure positive drainage. Whether a remote or direct drain system is flush with and under the home. Skirting may used, condensate should not be permitted to be employed if it allows access to the unit collect beneath the home.
  • Page 6: Vac Electrical Wiring

    7. 115 VAC ELECTRICAL WIRING WARNING - SHOCK HAZARD DANGER To prevent the possibility of severe personal injury or equipment damage due to electrical WHEN USING NON-METALLIC SHEATH shock, always be sure the electrical power is SUPPLY CABLES (ROMEX, ETC.), STRIP disconnected or off before beginning SHEATH BACK TO EXPOSE 4-6 INCHES installation.
  • Page 7: Thermostat And 24 Vac Wiring

    8. THERMOSTAT AND 24 VAC WIRING Routing of the thermostat wiring must comply with all local THERMOSTAT MOUNTING and national electrical codes. Collect any excess thermostat harness in the air conditioner mounting compartment. Be sure Follow the instructions packed with the thermostat to select a to secure the excess wiring within the compartment.
  • Page 8 TABLE DES MATIÈRES Avertissements ..........Jumelage de composants .
  • Page 9: Information Générale

    4. INFORMATION GÉNÉRALE Les climatiseurs monoblocs de série 6633 sont conçus pour L’air conditionné est acheminé du climatiseur à l’intérieur du une installation par les fabricants de maisons. Ces appareils véhicule par le biais de conduits fournis et installés par le sont «...
  • Page 10: Spécification De Conduit Et De Registres D'air

    d’étanchéité statique fourni par l’installateur forme de « tube-kazoo » est expédié dans la boîte de fils avec un adaptateur d’épissure entre l’appareil et le dessous de la maison. barbelé. Si vous décidez de drainer L’air déchargé s’acheminera directement directement le condensat de l’appareil, dans le conduit d’alimentation de la maison insérez le tube-kazoo dans l’oeillet de dans ce cas.
  • Page 11: Câblage Électrique 115 V.c.a

    Tout conduit exposé à des sources de chaleur doit être isolé plastique et de métal comptent en moyenne 30 à 60 % pour éviter toute réduction de performance importante suite au d’ouverture. Donc, la « surface libre » réelle de la grille sera de gain de chaleur.
  • Page 12: Thermostat Et Câblage 24 V.c.a

    ÉLECTRIQUE. LA GAINE DOIT OU CONNECTEURS DE RÉDUCTION RESSORTIR DE LA GARNITURE DE DE TENSION APPROPRIÉS. LA PINCE À L’INTÉRIEUR DE LA VOUS NE DEVEZ, EN AUCUN CAS, BOÎTE TEL QU’ILLUSTRÉ. ASSUREZ- PINCER OU RESSERRER LES FILS VOUS QUE LE CÂBLE GAINÉ EST D’ALIMENTATION INDIVIDUELS CENTRÉ...