Remove The Solenoid - Kohler K-10956 Maintenance Manual

Exposed electronic valve
Table of Contents

Advertisement

Available languages

Available languages

Cap
DC Sensor
Connector
Retaining Nut
Solenoid
Connector
Pin
Diaphragm

Remove the Solenoid

Close the control stop valve (refer to the "Control Stop Valve
Operation" section).
NOTE: If the unit has not flushed since the stop valve was closed,
the inlet arm may still be pressurized. Use the manual flush button
to release pressure.
Use a 3/32" hex head wrench to remove the setscrew from the
cap.
Remove the cap by lifting from the valve body.
Disconnect the DC sensor connector from the solenoid connector
by pulling the two connectors apart.
Temporarily store the cap and DC sensor assembly in a safe
place.
Use an adjustable wrench to remove the solenoid assembly from
the valve body by unscrewing counterclockwise until the solenoid
is free.
Kohler Co.
Setscrew
Solenoid
Assembly
Spring
Valve Body
11
O-Ring
Piston
Cover
Piston
1058866-5-D

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

K-10957K-10962K-10957-cpK-10959K-10964

Table of Contents