SCHOTT KL 1500 HAL User Manual
Hide thumbs Also See for KL 1500 HAL:

Advertisement

Quick Links

KL 1500 HAL
KL 1500 H
User Manual

Advertisement

Table of Contents
loading

Summary of Contents for SCHOTT KL 1500 HAL

  • Page 1 KL 1500 HAL KL 1500 H User Manual...
  • Page 2 KL 1500 HAL / KL 1500 H - Operating instructions Operating instructions KL 1500 HAL / KL 1500 H* Status: July 2018 *different name KL1500H possible. In this operating instructions for the sake of simplicity, only the KL 1500 HAL is mentioned in the text.
  • Page 3: Table Of Contents

    KL 1500 HAL / KL 1500 H - Operating instructions Contents Important information ................Operation ....................Light guide connection ................Power connection …………………………………………………………... Start up procedure .................. Light intensity setting ................. LCD display indication and settings …………………..……………….…. Supplementary optics ……………………………………………………….…… 9 Filter slide ....................
  • Page 4 KL 1500 HAL / KL 1500 H - Operating instructions The instrument at a glance On/off switch Light guide socket with automatic shut off Locking screw Electronic light intensity setting LCD display Pivot lever for supplementary optics Filter slide Carrying handle...
  • Page 5: Important Information

    High intensity visible light is guided to the object using flexible or self supporting, movable light guides. According to the EN 62471:2008 standard the KL 1500 HAL is a product of Risk Class 1. The KL 1500 HAL fibre optic light source conforms to the provisions of the following European...
  • Page 6 Please make sure that  your KL 1500 HAL cold light source is operated at the voltage stated on the model plate (13);  all air vents (11, 12) are kept clear at all times. In the event of insufficient cooling, an integrated thermo switch will cut off the instrument temporarily (see Point 5 "Troubleshooting")
  • Page 7: Operation

    The instrument needs to be connected to the mains supply (100-240 V AC, 50-60 Hz). Please ensure that you operate your KL 1500 HAL cold light source only within the specified voltage range. 2.3 Start up procedure...
  • Page 8: Light Intensity Setting

    Position O: The instrument is switched off. Please disconnect the power by pulling out the power plug! To protect the halogen lamp the KL 1500 HAL is fitted with a gentle start up device that reduces the high switch on current that would otherwise occur.
  • Page 9: Lcd Display Indication And Settings

    Attention: Please note that when the brightness control is set to 0%, the instrument is not switched off. You switch off the KL 1500 HAL by pressing the on/off switch (1) (see Point 2.3 "Start up procedure"). Please ensure safe power disconnection by pulling out the power plug! If necessary, you can have the total operating time of the lamp (varying with the set intensity) displayed on the LCD display (see Point 2.5 "LCD display indication and settings").
  • Page 10: Supplementary Optics

    KL 1500 HAL / KL 1500 H - Operating instructions checkmark will appear in the menu field). Select "Menu" followed by "Exit". The lamp will switch back on. The operating hours are indicated at the top left of the LCD display (5).
  • Page 11: Filter Slide

    2.7 Filter slide The KL 1500 HAL has a filter slide (7) which can be fitted with an insert filter (available as accessory). When operating the light source, the filter slide must always be engaged in one of the end positions or in the rest position.
  • Page 12: Lamp Change

    KL 1500 HAL / KL 1500 H - Operating instructions 3. Lamp change Safety information: ATTENTION! Please ensure that the lamp and lamp socket have cooled down before replacing the lamp. A warning sign has been attached to remind you of this necessity.
  • Page 13: Maintenance

    5. Troubleshooting Should you be unable to correct the fault you are experiencing applying the measures listed below, turn to your authorised dealer or the next SCHOTT dealership. More extensive repairs have to be performed by authorised service technicians. Errors and faults are commonly displayed on the LCD display (5) (see Point 2.5): Overheating: Insufficient cooling;...
  • Page 14: Accessories

    6. Accessories for KL 1500 HAL A wide range of accessories is available for your KL 1500 HAL. A separate brochure gives you comprehensive information (turn to page 15 for the order address) Only SCHOTT light guides and accessories guarantee perfect operation, safety and optimum light yield.
  • Page 15: Technical Data

    KL 1500 HAL / KL 1500 H - Operating instructions 6.4 Spare parts Halogen lamp 15 V / 150 W (catalogue no. 153000) Philips, type 6423 Philips, type 6423 XHP Osram, type HLX 64634 Lamp socket (catalogue no. 150710) Only the use of the spare parts listed above will ensure maximum performance, light yield and safety.
  • Page 16 KL 1500 HAL / KL 1500 H - Operating instructions Lighting information Maximum effective light guide bundle diameter Total light flux at light guide exit (SCHOTT light guide Ø 9 mm, typ. values) Level 50% approx. 250 approx. 450 Level 80% approx.
  • Page 17 SCHOTT North America, Inc. 122 Charlton Street Southbridge, MA 01550 Phone + 1 (508)765-9744 Fax + 1 (508)764-6273 lightingimaging@us.schott.com www.us.schott.com/microscopy...

This manual is also suitable for:

Kl 1500 h