C24EO SERIES STEAMERS - REMOVAL AND REPLACEMENT OF PARTS
5. Partially remove heating element assembly by
pulling assembly towards you.
6. Remove high limit thermostat bulb and bracket.
7. Remove heating element assembly.
Installation
NOTE: When replacing element assembly for 3 pan
unit with 240V supply, disconnect and insulate
element leads with orange, green, and red markers
(three 664W elements not used).
1. Completely and evenly coat heating element
assembly with thermal transfer compound using
notched trowel. (Use one 13.5 oz. tube of
thermal transfer compound)
2. Partially install heating element assembly, then
mount high limit thermostat bulb and bracket to
assembly.
A. Apply thermal transfer compound between
high limit bulb and heating element
assembly.
3. Install heating element assembly. Push element
assembly towards front of machine.
4. Connect lead wires to 1CON and 2CON in noted
positions.
5. Check steamer for proper operation.
2940 Hwy 14 W, Rochester, MN 55901
1. Remove right SIDE PANEL and REAR PANEL.
2. Remove pin and washer to disconnect the
3. Remove nut and linkage bracket.
4. Remove drain valve.
5. Reassemble parts removed in reverse order of
6. Check steamer for leaks and proper operation.