Four-Faith F-B200GLGL Hardware Design Manual

Nb-iot module

Advertisement

Quick Links

F-B200GLGL
NB-IoT
module hardware design
manual
F-B200GL NB-IoT Module
Hardware Design Manual
Document Version
F-B200GLGL
Xiamen Four-Faith Communication Technology Co., Ltd.
Add:
Floor
11,
street,Jimei,Xiamen
Tel: +86 592-5907276
Web: http://en.four-faith.com
V1.0.3
Area
A06,
Fax: +86 592-5912735
Security
35 pages
No
370,chengyi

Advertisement

Table of Contents
loading

Summary of Contents for Four-Faith F-B200GLGL

  • Page 1 Document Version Security F-B200GLGL NB-IoT module hardware design V1.0.3 manual F-B200GLGL 35 pages F-B200GL NB-IoT Module Hardware Design Manual Xiamen Four-Faith Communication Technology Co., Ltd. Add: Floor Area A06, 370,chengyi street,Jimei,Xiamen Tel: +86 592-5907276 Fax: +86 592-5912735 Web: http://en.four-faith.com...
  • Page 2 F-B200GL NB-IoT module hardware design manual Files Revised Record Date Version Remark Author 2019/7/2 V1.0.3 Initial version Jim Chen 2 / 34 Add: Floor 11, Area A06, No 370, chengyi street, Jimei, Xiamen. China http://en.four-faith.com Tel: +86 592-5907276 Fax: +86 592-5912735...
  • Page 3 All contents in the files are protected by copyright law, and all copyrights are reserved by Xiamen Four-Faith Communication Technology Co., Ltd. Without written permission all commercial use of the files from Four-Faith are forbidden, such as copy, distribute, reproduce the files, etc., but non-commercial purpose, download or printed by individual (all files shall be not revised, and the copyright and other proprietorship notice shall be reserved) are welcome.
  • Page 4 F-B200GL NB-IoT module hardware design manual Product Appearance BOTTOM 4 / 34 Add: Floor 11, Area A06, No 370, chengyi street, Jimei, Xiamen. China http://en.four-faith.com Tel: +86 592-5907276 Fax: +86 592-5912735...
  • Page 5: Table Of Contents

    Electrical Reliability and RF Performance............29 Absolute Maximum Rating..................29 Power Supply......................29 Operating Temperature..................... 29 Power Consumption....................30 Output Power......................30 5 / 34 Add: Floor 11, Area A06, No 370, chengyi street, Jimei, Xiamen. China http://en.four-faith.com Tel: +86 592-5907276 Fax: +86 592-5912735...
  • Page 6 Chapter6 Dimensions......................31 Module Dimensions....................31 Module Package......................32 Chapter7 Storage and Production..................32 Storage.........................32 Product Welding......................33 Package........................34 6 / 34 Add: Floor 11, Area A06, No 370, chengyi street, Jimei, Xiamen. China http://en.four-faith.com Tel: +86 592-5907276 Fax: +86 592-5912735...
  • Page 7: Chapter1 Product Overview

    Cat.NB1: Maximum uplink rate is 70kbps Maximum downlink rate is 32kbps Support Network Protocol PPP/TCP/UDP/COAP/MQTT/LWM2M/SSL/TLS/FTP(S)/HTTP(S). Support PAP (Password Authentication Protocol) and 7 / 34 Add: Floor 11, Area A06, No 370, chengyi street, Jimei, Xiamen. China http://en.four-faith.com Tel: +86 592-5907276 Fax: +86 592-5912735...
  • Page 8: Rf Block Diagram

    Used for software download, Module debug and log output The commands defined by 3GPP TS 27.007 and 3GPP TS 27.005, AT Command and add the new commands from Xiamen Four-Faith Technology Include the main antenna interface (ANT_MAIN) and the BT Antenna Interface...
  • Page 9: Chapter2 Application Interfaces

    1. Power supply interface 2. (U)SIM card interface 3. UART interface 4. I C interface 5. SPI interface 9 / 34 Add: Floor 11, Area A06, No 370, chengyi street, Jimei, Xiamen. China http://en.four-faith.com Tel: +86 592-5907276 Fax: +86 592-5912735...
  • Page 10: Pin Assignments

    3. Due to diode drop of chipset inside, The PWRKEY pin will output 1.0V 2.2 I/O Definition Form 2-1 I/O Definition 10 / 34 Add: Floor 11, Area A06, No 370, chengyi street, Jimei, Xiamen. China http://en.four-faith.com Tel: +86 592-5907276 Fax: +86 592-5912735...
  • Page 11: Pin Descriptions

    VDD_EXT power domain, GPIO_36 input/output unused state: float. General purpose VDD_EXT power domain, GPIO_34 input/output unused state: float. 11 / 34 Add: Floor 11, Area A06, No 370, chengyi street, Jimei, Xiamen. China http://en.four-faith.com Tel: +86 592-5907276 Fax: +86 592-5912735...
  • Page 12 Data receive unused state: float. UART4 interface Pad # Pad Name Description Remark HST_RXD Data receive VDD_EXT power domain, 12 / 34 Add: Floor 11, Area A06, No 370, chengyi street, Jimei, Xiamen. China http://en.four-faith.com Tel: +86 592-5907276 Fax: +86 592-5912735...
  • Page 13 Need connect with VBAT Only external GPS RTC LDO Output for V_BAT_RTC power supply, no load VBAT_RTC capacity ADC interface 13 / 34 Add: Floor 11, Area A06, No 370, chengyi street, Jimei, Xiamen. China http://en.four-faith.com Tel: +86 592-5907276 Fax: +86 592-5912735...
  • Page 14: Working Mode

    F-B200GL can make power consumption through the e-I-DRX mode. The power consumption of e-I-DRX slightly higher than PSM. But compared with PSM, the 14 / 34 Add: Floor 11, Area A06, No 370, chengyi street, Jimei, Xiamen. China http://en.four-faith.com Tel: +86 592-5907276 Fax: +86 592-5912735...
  • Page 15: Airplane Mode

    AT+CPSMS=1 or AT+CPSMS=1 command to enable PSM. When the module in PSM state, you can awaken the module under the following 15 / 34 Add: Floor 11, Area A06, No 370, chengyi street, Jimei, Xiamen. China http://en.four-faith.com Tel: +86 592-5907276 Fax: +86 592-5912735...
  • Page 16: Power Supply

    The reference design of the power supply circuit is as follows: Figure 2-2 Power Supply Reference Design 16 / 34 Add: Floor 11, Area A06, No 370, chengyi street, Jimei, Xiamen. China http://en.four-faith.com Tel: +86 592-5907276 Fax: +86 592-5912735...
  • Page 17: Module Startup/Shutdown

    Another way to control PWRKEY pin is through a button switch directly. A TVS is placed near the button for ESD protection. Figure 2-4 Button Startup Reference Circuit 17 / 34 Add: Floor 11, Area A06, No 370, chengyi street, Jimei, Xiamen. China http://en.four-faith.com Tel: +86 592-5907276 Fax: +86 592-5912735...
  • Page 18: Shutdown

    RESET_N pin, shown as follows: Figure 2-5 RESET_N Open Collector Drive Reference Reset Circuit Figure 2-6 RESET_N Button Reset Reference Circuit 18 / 34 Add: Floor 11, Area A06, No 370, chengyi street, Jimei, Xiamen. China http://en.four-faith.com Tel: +86 592-5907276 Fax: +86 592-5912735...
  • Page 19: U)Sim Interface

    If you do not need the USIM_PRESENCE pin to detect (U)SIM card, please keep it float. The reference circuit as follows: 19 / 34 Add: Floor 11, Area A06, No 370, chengyi street, Jimei, Xiamen. China http://en.four-faith.com Tel: +86 592-5907276 Fax: +86 592-5912735...
  • Page 20 (U)SIM card connector. 7. The pull-up resistor of USIM_DATA can increase the antijamming capability of 20 / 34 Add: Floor 11, Area A06, No 370, chengyi street, Jimei, Xiamen. China http://en.four-faith.com Tel: +86 592-5907276 Fax: +86 592-5912735...
  • Page 21: Uart Interface

    Receive data Unused state: float VDD_EXT power domain, UART3_TXD Transmit data Unused state: float Form 2-12 UART4 Pins Description 21 / 34 Add: Floor 11, Area A06, No 370, chengyi street, Jimei, Xiamen. China http://en.four-faith.com Tel: +86 592-5907276 Fax: +86 592-5912735...
  • Page 22 22 / 34 Add: Floor 11, Area A06, No 370, chengyi street, Jimei, Xiamen. China http://en.four-faith.com Tel: +86 592-5907276 Fax: +86 592-5912735...
  • Page 23: I2C Interface

    Form 2-14 STATUS Pin Description Pad # Pad Name Description Remark STATUS Working status indication 1.8V power domain Reference Design: 23 / 34 Add: Floor 11, Area A06, No 370, chengyi street, Jimei, Xiamen. China http://en.four-faith.com Tel: +86 592-5907276 Fax: +86 592-5912735...
  • Page 24: Chapter3 Bt Function

    In order to the regulation of RF performance better, it is recommended to reserve the π-type marching circuit. The π-type matched components (R1/C1/C2) should be 24 / 34 Add: Floor 11, Area A06, No 370, chengyi street, Jimei, Xiamen. China http://en.four-faith.com Tel: +86 592-5907276 Fax: +86 592-5912735...
  • Page 25: Rf_Ant Layout Guideline

    1.Complete structure of microstrip line Figure 4-2 Two Layers PCB Microstrip Line Structure 2. Complete structure of coplanar waveguide 25 / 34 Add: Floor 11, Area A06, No 370, chengyi street, Jimei, Xiamen. China http://en.four-faith.com Tel: +86 592-5907276 Fax: +86 592-5912735...
  • Page 26 RF performance; The distance between the ground hole 26 / 34 Add: Floor 11, Area A06, No 370, chengyi street, Jimei, Xiamen. China http://en.four-faith.com Tel: +86 592-5907276 Fax: +86 592-5912735...
  • Page 27: Bt Antenna Interface

    Polarization type: vertical direction Cable insert depletion: <1.0dB (LTE B5/B8) Cable insert depletion: <1.5dB (LTE B3) BT Antenna Frequency range: 2400~2500MHz 27 / 34 Add: Floor 11, Area A06, No 370, chengyi street, Jimei, Xiamen. China http://en.four-faith.com Tel: +86 592-5907276 Fax: +86 592-5912735...
  • Page 28 VSWR: <2 (typical value) The RF Connector recommend to use Hirose UF.L-R-SMT. Figure 4-7 UF.L-R-SMT Connector Size(Unit: mm) 28 / 34 Add: Floor 11, Area A06, No 370, chengyi street, Jimei, Xiamen. China http://en.four-faith.com Tel: +86 592-5907276 Fax: +86 592-5912735...
  • Page 29: Chapter5 Electrical Reliability And Rf Performance

    3GPP standard. It means that when the module working in this temperature range, the module 29 / 34 Add: Floor 11, Area A06, No 370, chengyi street, Jimei, Xiamen. China http://en.four-faith.com Tel: +86 592-5907276 Fax: +86 592-5912735...
  • Page 30: Power Consumption

    3GPP (dBm) LTE-FDD B3 Support < -115 LTE-FDD B5 Support Nonsupport < -115 LTE-FDD B8 Support < -115 30 / 34 Add: Floor 11, Area A06, No 370, chengyi street, Jimei, Xiamen. China http://en.four-faith.com Tel: +86 592-5907276 Fax: +86 592-5912735...
  • Page 31: Electronic Static Discharge (Esd)

    All sizes without tolerance, the tolerance is 0.15mm. ± 6.1 Module Dimensions 15.2mm 17mm Figure 6-1 F-B200GL Top-View and Side-View 31 / 34 Add: Floor 11, Area A06, No 370, chengyi street, Jimei, Xiamen. China http://en.four-faith.com Tel: +86 592-5907276 Fax: +86 592-5912735...
  • Page 32: Module Package

    3. If the module is in the following conditions, it needs to be baked before the SMD: 32 / 34 Add: Floor 11, Area A06, No 370, chengyi street, Jimei, Xiamen. China http://en.four-faith.com Tel: +86 592-5907276 Fax: +86 592-5912735...
  • Page 33: Product Welding

    PCB board completes the reflow welding. The recommended furnace temperature curves are shown as follows: Figure 7-1 Reflow Temperature Curve 33 / 34 Add: Floor 11, Area A06, No 370, chengyi street, Jimei, Xiamen. China http://en.four-faith.com Tel: +86 592-5907276 Fax: +86 592-5912735...
  • Page 34: Package

    194.21mm long and 184.18mm width, include 49 F-B200GL modules. The pallet size is shown as follows: Figure 7-2 Pallet Size 34 / 34 Add: Floor 11, Area A06, No 370, chengyi street, Jimei, Xiamen. China http://en.four-faith.com Tel: +86 592-5907276 Fax: +86 592-5912735...

Table of Contents