Summary of Contents for CBS ArcSafe RSA-138A

  • Page 1 B E T W E E N Y O U A N D Gainesville, Texas 76241 A R C - F L A S H D A N G E R ? ® Copyright CBS ArcSafe 2013 Printed in the United States of America 2616 Sirius Road...
  • Page 2 RRS-4 – PLC Based Universal Remote Racking System (Rotary) The CBS ArcSafe® RRS-4 universal remote racking system is an updated PLC based version of the best selling RRS-1. The dual mode, source programmable, PLC based control system offers two different operating modes to choose from based on user preference or the application.
  • Page 3: Installation

    ANGER Before servicing any breaker, make sure that it matches the breaker discussed. If the breaker does not match the breaker described above, please call CBS ArcSafe® for more information. TTENTION The location of certain items such as mimic bus, stickers, and/or placards may interfere with the proper installation of the RSA.
  • Page 4 3. Ensure that the upper locator on the RSA is flush with the top and side of the switch escutcheon, as shown. 4. Turn the handles of the twit-lock magnets 180° clockwise to lock the RSA in place 5. Install the interlock defeat onto the switch handle, as shown. RSA-138A Installation and Operation...
  • Page 5 The RSA is now ready for remote operation RSA-138A Installation and Operation...
  • Page 6: Operation

    TRIP button on the RSO-I AR until the breaker is tripped. 7. If the breaker is OPEN and needs to be close, press and hold the CLOSE button on the RSO-I AR until the breaker is closed. RSA-138A Installation and Operation...
  • Page 7 1. Loosen the two bolts on the locator plate, as shown below. 2. Slide the locators up or down as necessary to position them flush to the upper and side edge of the han- dle escutcheon. 3. Re-tighten the four bolts. RSA-138A Installation and Operation...
  • Page 8: Travel Adjustment

    2. Loosen the lock screws on the backs of the two switch wheels. 3. With the RSA operator arm in the OPEN position, rotate the outer limit switch cam in the direction of travel for the arm, until a slight click is heard. Re-tighten the lock screw. RSA-138A Installation and Operation...
  • Page 9 4. With the RSA operator arm in the CLOSED position, rotate the inner limit switch cam in the direction of travel for the arm, until a slight click is heard. Re-tighten the lock screw. RSA-138A Installation and Operation...
  • Page 11 Notes RSA-138A Installation and Operation...
  • Page 12 RSA-138A Installation and Operation 2616 Sirius Road Denton, TX 76208 Tel: 877-4-SAFETY Fax: 940-382-9435 Website: www.CBSArcSafe.com Email: info@CBSArcSafe.com ANGER Ensure that personnel using this equipment are adequately trained in the operation of the switchgear they are planning to work with; that they are correctly stationed outside the arc flash boundary;...