TROUBLESHOOTING (CONT)
Error Display (Indoor Unit)
When the indoor unit encounters a recognized error, the indicator light flashes in a corresponding series, the timer display may turn on or begin
flashing, and the error code displays. See Table 9 for the error codes and meanings.
DISPLAY
Indoor unit EEPROM parameter error
EH 00/EH 0A
EL 01
Indoor / outdoor unit communication error
Zero-crossing signal detection error
EH 02
Over low voltage protection of indoor external fan
EH 30
EH 31
Over voltage protection of indoor external fan
The indoor fan speed is operating outside of the normal range
EH 03
EC 51
Outdoor unit EEPROM parameter error
Condenser coil temperature sensor T3 is in open circuit or has short circuited
EC 52
Outdoor room temperature sensor T4 is in open circuit or has short circuited
EC 53
EC 54
Compressor discharge temperature sensor TP is in open circuit or has short circuited
Evaporator coil outlet temperature sensor T2B is in open circuit or has short circuited
EC 56
Eh 60
Indoor room temperature sensor T1 is in open circuit or has short circuited
Evaporator coil temperature sensor T2 is in open circuit or has short circuited
Eh 61
The outdoor fan speed is operating outside of the normal range(
EC 07
EH 0
Indoor PCB/Display board communication error
Refrigerant leak detected
EL 0C
PC 00
IPM malfunction or IGBT over-strong current protection
Over low voltage protection
PC 10
PC 11
Over voltage protection
DC voltage protection
PC 12
Compressor top high temperature protection (OLP)
PC 02
PC 03
Pressure protection
Communication error between outdoor main chip and compressor driven chip
PC 40
Pc 41
Current Input detection protection
Compressor start error
PC 42
Lack of phase (3 phase) protection
PC 43
PC 44
No speed protection
341PWM error
PC 45
PC 46
Compressor speed malfunction
Compressor over current protection
PC 49
Indoor units mode conflict (match with multi outdoor unit)
--
PC 0A
Condenser high temperature protection
Compressor discharge temperature protection
PC 06
PC 08
Outdoor current protection
Anti-cold air in heating mode
PH 09
PFC module malfunction
PC 0F
pc 0l
Outdoor ambient temperature too low
Evaporator coil temperature over high protection
PH 90
PH 91
Evaporator coil temperature over low Protection
Frequency limit caused by voltage
LC 05
Frequency limit caused by current
LC 03
LC 02
Frequency limit caused by TP
Frequency limit caused by T3
LC 01
LH 00
Frequency limit caused by T2
Frequency limit caused by PFC
LC 06
Frequency limit caused by remote controller
LH 07
nA
no malfunction or protection
For other codes
The display board may show a garbled code or a code undefined by the service manual. Ensure that this code is not a temperature reading.
Troubleshooting
Test the indoor unit using the remote controller. If the unit display is working however will not respond to the remote, the indoor PCB needs
replacing. If there is no display after pressing LED and the unit responds, the display board needs replacing.
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
Table 9 — Error Codes