Troubleshooting; Error Display - Midea MP15EMC62 Service Manual

Table of Contents

Advertisement

10. Troubleshooting

10.1 Error Display

Codes
AS
Open or short circuit of T1 temperature sensor
ES
Open or short circuit of T2 temperature sensor
CS
Open or short circuit of T3 temperature sensor
OS
Open or short circuit of T4 temperature sensor
HS
Open or short circuit of T5 or T6 temperature sensor
Lo
Temperature is lower than display range (32°F)
HI
Temperature is higher than display range (99°F)
E4
Communication malfunction between main control board and display board
LE
Drive-by-wire control failure
10.2 Troubleshooting
10.2.1 Open circuit or short circuit of temperature sensor diagnosis and solution (AS/E5/CS/oS/HS).
Error Code:
Malfunctioning conditions:
Possible causes:
Troubleshooting:
Check the connection
between temperature
sensor and PCB. It is
properly connected?
Measure the resistance
Replace indoor main PCB.
AS/ES/CS/OS/HS
If the sampling voltage is lower than 0.06V or higher than
4.94V, the LED will display the failure.
Wiring mistake
Faulty sensor
Faulty PCB
Yes
value of the sensor.
Yes
Explanations
No
Correct the connection.
Replace the sensor.
No
www.mideaaircon.com 28

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ptac seriesMp12emc62Mp12emb63

Table of Contents