    Current Voltage Tester Content 1.0 Introduction / Product Package 2.0 Safety Measures 3.0 Danger of electric shock and other dangers 4.0 Intended Use 5.0 Testers Information 6.0 Preparation for tests 6.1 Auto-power on/ switching on 6.2 Auto-power off 7.0 Conducting Tests Voltage test 7.1.1 Low Voltage mode Current Test...
  • Page 2: Introduction / Product Package

    A voltage tester of relatively high internal impedance, compared to the reference value of 100 k�, may not The KT5 is a universal tester for voltage, current, continuity permit to clearly indicate the absence of operating and rotary field testing with various secondary features.
  • Page 3: Danger Of Electric Shock And Other Dangers

    4.0 INTENDED USE 3.0 DANGER OF ELECTRIC SHOCK AND OTHER DANGERS The tester may be used only under the conditions and for the purposes for which it was designed. Therefore, observe To avoid an electric shock, observe the precautions when in particular the safety instructions, the technical data working with voltages exceeding 120 V (60 V) DC or including environmental conditions.
  • Page 4: Preparation For Tests

    LCD Display information 7.1.1 Low Voltage mode – 1V-1000VAC/1500VDC 1. HOLD symbols • Press On/Off/Function button repeatedly until the LCD shows <10V symbol. 2. AC/ DC and polarity symbols • In Low Voltage mode it is possible to measure AC and 3.
  • Page 5: Continuity Test

    7.9 CABLE BREAK DETECTION BY NCV 7.5 CONTINUITY TEST L RX • Switch into NCV detection by pressing On/off- Make sure the object under test is not live. function button repeatedly. LCD will show the NCV • Connect both test probes to the object under test. symbol.
  • Page 6: Technical Data

    10.0 CLEANING AND STORAGE 9.0 TECHNICAL DATA Tester does not need any special maintenance if 1…1000 V AC (15…800 Hz), Voltage Range used according to user manual. 1…1500 V DC(±) Remove tester from all test points before cleaning. LED nominal Voltage 120 / 230 / 400 / 690 / 1000 V Use a lightly damp cloth with neutral detergent LED tolerances EN 61243-3...
  • Page 7 FREE TWO YEAR GUARANTEE Kewtech’s Two Year Warranty enhances customers’ legal rights. It covers all manufacturing defects for a two year period but Kewtech reserves the right to exclude abuse or accidental damage. RE-CALIBRATION SERVICE Regular re-calibration is recommended for this instrument. Kewtech recommends...