Appendix 1 5.3 EMC Getting Started Quickly 6. Configuration 6.1 Default configuration 6.2 Accessing the configuration menus 6.3 Summary of configurable functions 6.4 Quick access menu The BA684D is CE marked to show compliance with the European EMC Directive 2004/108/EC...
(GRP) enclosure with an armoured glass window, the BA684D is surface mounting, or may be pipe mounted using one of the accessory kits. The BA684D is available with an RS232 or with an RS485 communication port. 1.1 Documentation This instruction manual describes system design, conditioning and installation of the BA684D serial text display.
Display – Modbus Guide, which is available from allows the instrument to replace an MTL643 IS text the BEKA sales office and from the BEKA web site. display for safe area (non hazardous) applications. For more demanding applications BEKA protocol...
BEKA protocol is described in the Serial Text Display – Programming Guide which is available from the BEKA sales office and from the BEKA Four variables + vertical bargraphs web site. Eight variables + horizontal bargraphs...
4. SYSTEM DESIGN 4.3 Switch outputs Figure 1 shows a functional block diagram of The BA684D serial text display has two single pole BA684D serial text display. Terminal locations are relay outputs which may be used for switching shown in Fig 4.
5. INSTALLATION 5.1 Location The BA684D serial text display is housed in a robust IP66 glass reinforced polyester (GRP) enclosure incorporating armoured glass window and stainless steel fittings. It is suitable for exterior mounting in most industrial environments, including off-shore and waste water treatment installations.
Page 8
Fig 4 Dimensions and terminal connections...
Page 9
When entering an access code, timeout will occur and the instrument will automatically return to the The BA684D is configured via the four front panel operating mode ten seconds after the push-buttons push-buttons. All the configuration functions are were last operated.
This function enables the quick access menu than the default code 0000 has already been described in section 7.4. When ‘On’ is selected entered, the BA684D will request that the access an operator can adjust the screen brilliance and code be entered.
ENSURE PLANT SAFETY BEFORE If a BA684D fails to function during commissioning STARTING MAINTENANCE the following procedure should be followed: If a BA684D fails after it has been functioning correctly, the table shown in section 7.1 may help Symptom Cause Check: to identify the cause of the failure.
8. ACCESSORIES 8.1 Tag number The BA684D can be supplied with a blank or custom engraved stainless steel plate secured by two screws to the side of the instrument enclosure. This plate can accommodate: 1 row of 9 alphanumeric characters 10mm high...
Select one of the standard screens shown in section 3.3 from the ‘Screens’ sub-menu. Communication 1. Connect dc power supply to the BA684D as Modbus register addresses for the instrument are shown in Fig 4. shown in the BEKA Serial Text Display – Modbus Interface Guide, which is available from the BEKA 2.