5.7.4 Status text 5.7.5 Last input 5.7.6 Keys 5.7.7 Code 5.7.8 Unit info 5.7.9 Defaults 5.7.10 Display defaults 5.7.11 Interface board defaults 5.8 Quick access menu The BA688CF-F is CE marked to show compliance with the European EMC Directive 2014/30/EU...
BEKA website. Fieldbus compliance verified to ITK 6.3 Most of the BA688CF-F display parameters are configured on-site via the fieldbus. Screen format Option added to remove status text from selection and alarm configuration is performed single variable screens.
When the optional alarms are not fitted, the of screens available depends upon how the instrument only requires a two-wire connection to BA688CF-F display has been configured. If one the fieldbus. fieldbus variable per screen has been configured, eight screens will be present; if four fieldbus...
3. SYSTEM DESIGN 3.2 Alarm outputs Each alarm output is a galvanically isolated single The BA688CF-F FOUNDATION™ fieldbus display pole solid state switch output as shown in Fig 3. may be connected to any fieldbus segment as shown in Fig 2 providing it can provide the...
Fig 4 shows the overall dimensions of the simplify installation, terminals BA688CF-F and the panel cut-out. To achieve an removable so that panel wiring can be IP66 seal between the instrument enclosure and completed before the instrument is installed. the panel, the smaller cut-out must be used and the instrument secured with four panel mounting clips.
4.3 EMC The BA688CF-F complies with the requirements of the European EMC Directive 2014/30/EU. specified immunity all wiring should be in screened twisted pairs with the screens connected to the plant’s potential equalising network.
Defines the position of the 5.3 Default configuration Display_format displayed decimal point. Unless otherwise requested at the time of ordering, Six options are available: BA688CF-F FOUNDATION™ fieldbus displays will be supplied configured as follows: Auto Max resolution with selected display format. Keys...
5.4 Accessing the instrument configuration 5.5 Screen selection menu. The BA688CF-F can display up to eight fieldbus Throughout this manual push buttons are shown in variables. These are identified as IN_1 to IN_8. italics e.g. P E ▼ ▲ and legends displayed by...
Page 10
One variable + vertical bargraph Two variables + vertical bargraphs Three variables + vertical bargraphs Four variables + vertical bargraphs Eight variables + horizontal bargraphs...
Note: Alarm menus are only included when the independently enabled to condition the output as a BA688CF-F is fitted with optional alarm outputs. low or high alarm, or as a combined low and high Outputs are locally activated from the fieldbus alarm, either with or without hysteresis.
BA688CF-F front panel push buttons. The table below shows the function of the BA688CF-F front panel and the 5.8 Quick Access Menu external push buttons for each of the four options The Quick Access Menu allows an operator to that may be selected in the Keys sub-menu.
STARTING MAINTENANCE 6.1 Fault finding during commissioning If a BA688CF-F FOUNDATION™ fieldbus display If a BA688CF-F fails after it has been functioning fails to function during commissioning the following correctly, the table shown in section 6.1 may help procedure should be followed: to identify the cause of the failure.
7. ACCESSORIES 7.1 Tag number The BA688CF-F can be supplied with a thermally printed tag number on the rear panel. This tag number is not visible from the front of the instrument after installation. 7.2 FOUNDATION™ fieldbus Interface Guide The BEKA FOUNDATION™ fieldbus Interface Guide which may be downloaded from the BEKA web site at www.beka.co.uk contains configuration...