Adjustment Allen screws are
provided on each side of the lift
platform for adjusting the platform
angle. Adjust platform angle as
specified on previous page.
Platform Angle
Adjustment Screws
A
Right
Must make full contact.
Vertical
Stop
Arm
Block
C
Platform Angle Adjustment
To raise the outboard end
of platform - turn adjustment
screw clockwise.
To lower the outboard end
of platform - turn adjustment
screw counterclockwise.

Platform Stop Blocks

Stop Block Guideline
All Lift Models
Both stop blocks must
make full contact with
the edge of vertical arms.
When adjusting platform
angle, setting floor level
position or adjusting
bridging microswitch -
ensure both stop blocks
are making full contact
with the vertical arms.
Note: Both adjustment screws
must be adjusted equally.
Apply Loctite
screws following adjustment.
Adjustment Screw
Turn
counter-
clockwise
to lower
outboard
end of
platform
Turn
clockwise
to raise
outboard
end of
platform
Gap not permitted.
Vertical
Arm
®
to adjustment
Allen Head
B
Wrong
Stop
Block
D