Autoset from
Program panel to Autoset and press OK, 3,2,1.
open position is reached press the OK button 3.2.1.
the open position is reached press the OK button.
With
showing press the OK button 3.2.1,
closed position is reached press the OK button 3.2.1.
when the closed position is reached press the OK button.
With
showing press the OK button 3.2.1. motor 1 will open followed by motor
2, from the open position motor 2 will close first followed by motor 1, upon
completion OK will be displayed.
If the motors try to close at the launch of the Autoset then the motor cables must be
swapped 10&12, 14&16. When a gate system is powered for the first time or after a
power cut, the gates must move to the open position when a command is given.
Increase the working time in the Parameter menu under work t if required
motor 1 will open, when the
motor 2 will open, when
motor 2 will close, when the
motor 1 will close,