DESCRIPTION & USE
INTRODUCTION
The LifeSpeed IQ
TM
range of chargers is designed to recharge
24 V, 36 V, 48 V, 72V or 80 V batteries with 3-phase mains
supply. The micro processor-controlled unit automatically
recognises the battery (voltage, capacity, charge level, etc.)
and very effectively analyses its condition for optimum
handling. Several charging profiles are available (vented
lead/acid batteries, Hawker
or Water Less
®
/Water Less
configuration selected by the user. The capability for
desulphation, equalisation and refresh charging is also
included.
EXTERNAL COMPONENTS
Presented below:
1
4
5
8
9
Ref. Function
1.
Control Panel with LCD display
2.
USB port
3.
Navigation button
4.
Modules
5.
Input cable
6.
Connectors for options:
Ethernet, Electrovalve, Lifenetwork IQ
7.
Output cables
8.
Output cables (dual harness only)
9.
Ventilation panels
Figure 1: Principal components of the charger.
CONTROL PANEL
Incorporates LCD Display, USB port and navigation button.
LCD Display
The display is fitted with 5 different colours indicating the
status of the charger:
COLOUR
FUNCTION
Dark blue
Waiting status until battery connected
Light blue
Battery on charge
Alternating, on charge indicating a pump
Light blue Orange
defect, overdischarge, thermal fault or
module failure
Green
Battery charged
Charger faults DF1, DF2, DF3, TH,
Red
WRG MOD
Alternating, battery charged with pump
Green
Orange
defect, overdischarge or module failure
XFC
batteries, gel batteries
®
TM
®
20 batteries) depending on the
Navigation button
Functions of the keys
The keys offer the following general functions:
Key
GREEN/RED
2
3
6
UNPACKING
7
The charger is delivered with the following:
2 m AC mains cable.
3 m DC battery cable.
This technical manual.
MECHANICAL INSTALLATION
The charger is intended to be floor standing and must be
installed in the vertical orientation. The distance between
2 adjacent chargers should be at least 0.3 m.
See paragraph Recommendations and avoid areas where
the chargers may be splashed with water, or saline
environments.
ELECTRICAL CONNECTIONS
3-phase input
Connection to the mains supply is 400V AC 3-phase and
must be connected using a suitable plug and adequately
sized circuit breaker (not included). Current requirements in
Amps are indicated on the charger information plate.
Battery output
It is essential to ensure correct polarity. However, reversed
polarity will result in blowing the output fuse, inability to
charge and the fault code DF2 will be displayed. See Fault
Codes.
Connection to the battery should be done using the cables
supplied:
RED cable: battery POSITIVE.
BLACK cable: battery NEGATIVE.
FACTORY SETUP
The charger is delivered with a factory setup as follows:
Profile:
Output DC cable length:
Configuration:
Automatic equalisation:
Delayed start enabled:
Function
Navigation in the menu.
Start/End of list (Press 2 seconds)
The central button is equipped with
a two-coloured LED Green/Red
(Green: charger is waiting, Red charger
operating)
Stop or Start of charge
Selection of active menu or validation
of value stored
Cancel the value stored
(Press 2 seconds)
Start an equalisation charge.
Access to a sub-menu.
Access to the menus (press 3 seconds)
Close the window.
As ordered
3 m
As ordered
No