Download Print this page

Candy CDE 701 T User Instructions page 22

Advertisement

Available languages
  • EN

Available languages

Activating and deactivating the audible signal
The audible signal function can be deactivated in the following way:
keep the "Programme Selection Button"
seconds and at the same time press the stop/start button
symbol "b1" appears on the display the audible signal is activated.
Press the "Programme Selection Button"
"b0" will appear which means that the audible signal has been
deactivated.
An audible signal sounds to indicate that the setting has been stored in
memory.
The Dishwasher is able to self-assess a number of problems. The problem will
be illustrated in the display window and by an audible signal.
PROBLEMS AUTOMATICALLY SIGNED
PROBLEM
Water supply switched off.
Display shows E1.
Problem with electronic temperature
Display shows E2.
control.
Display shows E3.
The Water Heater Element does not
work properly or the filter mesh is
blocked.
The appliance does not discharge
Display shows E4.
water.
(P)
pressed in for a few
Pr
(P)
again and the symbol
Pr
CAUSE
REMEDY
Switch off appliance.
Turn on water supply.
Reset the cycle.
Call Service for assistance.
Clean the Filter Mesh and if the
problem continues please contact
Service.
Check :
• That the discharge hose is not
bent
• Syphon is not blocked
• Filters are not blocked
42
Regulating the water softener
with electronic programmer
; if the
I
The water softener can treat water with a hardness level of up to 90°fH (French
grading) or 50°dH (German grading) through 8 settings.
The settings are listed in the table below:
Level
0
1
2
3
4
5
6
7
The softener unit is set in the factory at level 4 (D4) as this satisfies the requirements
of the majority of users. Regulate the setting of your water softener unit according to
the degree of hardness of your water as follows: keep the delay start button
in and at the same time press the stop/start button
The factory setting "D4" will appear on the display. To change the setting, press the
start delay button
one level. When you have reached "D7", the display will go back to "D1".
When the required setting appears on the display, wait for an audible signal to
confirm that the new setting has been stored in memory.
Water
Water
Use of
hardness
hardness
regenerating
°fH
°dH
salt
(French)
(German)
0-5
0-3
NO
6-10
4-6
YES
11-20
7-11
YES
21-30
12-16
YES
31-40
17-22
YES
41-50
23-27
YES
51-60
28-33
YES
61-90
34-50
YES
.
I
. Each time you press that button the setting will increase by
Pr
1
2
DISPLAY
43
Water
softener
setting
D1
D1
D2
D3
D4
D5
D6
D7
pressed

Advertisement

loading