(7) Hotel Mode
(No description in the instruction manual)
1 Hotel Mode Specifications
1. Main power link
The last operation is remembered when the power is turned OFF and operation is performed in the
remembered operation mode when the power is turned back ON.
Example: The last set operation mode is remembered so if "Normal" is set and then the power plug
is pulled out or if the operation is turned OFF, the unit will automatically begin the "Normal" operation
next time.
2. The filter replacement lamp does not light.
2 How to Check Whether It Is Time for a Filter Replacement
Press the reset button once.
If it is time for a filter replacement, the LED lights for 5 seconds.
If no LED lights when you press the reset button, it is not time for a replacement.
CAUTION: Pressing the reset button for 2 or more seconds will clear the accumulated times.
3 How to Set Hotel Mode and Normal Mode
1. Insert the power cord plug into the power outlet.
2. When operation is OFF, press the reset button 10 times within 10 seconds.
• When the mode is switched from normal mode to hotel mode
1 The buzzer makes a "bleep" sound.
2 All the odor monitor lamps and PM2.5 monitor lamp light.
• When the mode is switched from hotel mode to normal mode
1 The buzzer makes a "blip blip" sound.
2 All operation mode lamps light.
* The set mode is retained even if the plug is removed from the power outlet.