7. Control Outline

(1) Function Operation List
Blower fan A and B
Automatic rotation turntable
Human sensing unit
Louver A and B
Operation mode
Operation switch
Odor monitor
PM2.5 monitor
Dust monitor
Filter replacement
Human sensing unit
Power
Manual
Auto
Reset
<Lamp Indication>
(1) Operation mode lamps (Low, Mid, High,
Night, and Normal)
• Operation mode is indicated.
• One lamp is lit during operation.
• The "Normal" lamp is lit by default (automatic
operation).
(2) Operation switch lamps
• The mode switches are indicated while operation is
ON.
(3) "Replace Filter" lamp
• The lamp is lit when the operation time reaches the
set value (approx. 4.5 years for "Low" operation and
approx. 8 months for "High" operation).
(2) Fan Control
„ Rank for Rotation Speed
1 The fan rotation speed for each fan rank is controlled as follows.
2 EEPROM holds the rotation speed data and pulse initial value.
Fan rank
Fan A rotating speed (rpm)
Fan B rotating speed (rpm)
Air volume (m
Operation OFF
OFF
Stops at the
center
Stops at the
center
CLOSE
OFF
OFF
OFF
OFF
OFF
OFF
OFF
Yes
No
No
Yes
1
350
350
3
/h)
84
Operation status
Automatic operation
Night
Normal
ON
ON
Stops at the
center
Stops at the
center
ON for the selected operation mode
ON when the accumulated time for filter replacement is reached
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
(4) Clean monitors
• The lamps are lit in accordance with the state of
odor, PM2.5, and dust contamination.
• The lamp color changes between "OFF", "Orange",
and "Red" depending on the level of contamination.
(5) Human sensing lamp
• The lamp is lit in accordance with the state of odor,
PM2.5, and dust contamination.
• The lamp color changes between "Green" and
"Orange" depending on the level of contamination.
(The lamp is always lit in "Green" except when it is
in the "Orange" state.)
• The lamp flashes slowly while detecting people with
the human sensing unit.
2
3
4
380
470
680
380
470
680
102
150
240
12
Manual operation
Low
Mid
ON
ON
Moves and stops repeatedly
Moves and stops repeatedly
OPEN
ON
ON/OFF
ON/OFF
ON/OFF
Green/Orange
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
5
6
800
1050
800
1050
300
450
High
ON
Yes
Yes
Yes
Yes
7
1380
1380
600