Page 1
Operating manual Original operating manual SENTA PUR L Combination bathing lift Version 2.5/English Subject to technical modifications 2019-04-08...
Control unit, North-American version ............18 7.2.3 Explanation of the LED-indications ............18 24V battery unit ....................19 External charging unit/wall charger ..............19 Manual emergency lowering system ..............20 Electrical emergency lowering system ............21 Operating manual SENTA PUR L V2.5 E Page 2 of 64...
Page 3
Emergency stop switch ...................22 Crash protection .....................22 Operation ......................23 Prior to use .....................23 Using the SENTA PUR L as sitting lift ............23 Using the SENTA PUR L as stretcher lift ............24 Function of the safety armrests ..............24 8.4.1 Assembly/disassembly of the safety armrests .........25 Disassembly/assembly of the adjustable wings ..........25...
Page 4
Technical data .....................53 14.2 Dimensions of the SENTA PUR L ...............54 14.3 Declaration of conformity ................55 14.4 Spare parts and accessories of the SENTA PUR L ........56 14.5 Electromagnetic Compatibility ..............57 14.6 Journal ......................61 Operating manual SENTA PUR L V2.5 E...
1.1 Acknowledgement Dear customer, we would like to express our sincere thanks for the trust you have placed in us by purchasing this BEKA Hospitec GmbH product. Our products are manufactured and tested according to stringent quality criteria. 1.2 Manufacturer’s address BEKA Hospitec GmbH Am Rübenmorgen 3...
Subject to technical modifications and error. • The SENTA PUR L product is equipped with “B”-Type applied parts. All exposed, touchable, conductive parts are thereby considered as applied part. Operating manual SENTA PUR L V2.5 E...
3.3 Description In the operating manual, the product is called SENTA PUR L, SENTA, combination bathing lift, bathing lift or lift. These designations all refer to the same device. Operating manual SENTA PUR L V2.5 E...
Safety 4 Safety 4.1 Intended and appropriate use The SENTA PUR L product has been designed for lifting and transferring patients in hospitals, nursing homes and care centres. The product provides support during the bathing process. The patient can be lifted from standing either reclined position. The SENTA PUR L combination bathing lift is to be used exclusively for the indoor transport of residents on smooth and level floorings.
CE-label in accordance with the EC-Directive on Medical Devices. Solely intended for indoor use. Protection class II. IPX4 Protection against the penetration of solids and liquids Operating manual SENTA PUR L V2.5 E Page 9 of 64...
▪ Never cover up, oversticker or change the slots and holes of the device. ▪ The SENTA PUR L combination bathing lift is exclusively fit for indoor use. ▪ Please make sure that the patient firmly holds the safety armrests.
Page 11
▪ The product must be cleaned and disinfected after each use. ▪ Avoid slippery surfaces and thresholds. ▪ Do not move the SENTA PUR L combination bathing lift over sloping or uneven floors. ▪ Supervision of the caregiver is required throughout the treatment.
Note: Do not cut in the cardboard, as this could damage the surface of the combination bathing lift! • Lift the cardboard up to remove it and put it aside Operating manual SENTA PUR L V2.5 E Page 12 of 64...
Remove the bubble wrap and the stretch film. Please take care not to damage the surface of the lift with the tools. Your lift accessories are included in the supplied cardboard box. Operating manual SENTA PUR L V2.5 E Page 13 of 64...
The SENTA PUR L combination bathing lift is supplied ready for use. 6.1 Electrical connection The SENTA PUR L combination bathing lift is equipped with a 24V-battery system. A VDE 0100 and 0100-710 compliant power connection is required for the wall charging unit.
Description Footrest (optional) Side rails (optional) Adjustable stretcher lift wings (optional) Removable backrest as headrest CAUTION: The extremities of the wings (n° 3) must not be used as seat! Operating manual SENTA PUR L V2.5 E Page 15 of 64...
Description Handset Allen wrench for the manual emergency lowering Control box and battery, moveable 7.1 Handset N° Description N° Description Seat/stretcher up Service indication Overload Battery charge level indication Operating manual SENTA PUR L V2.5 E Page 16 of 64...
N° Description N° Description Emergency stop switch Lifting motor connection Electrical emergency lowering system (buttons for use in case of handset Not used, sealed with caps malfunction) Handset connection Operating manual SENTA PUR L V2.5 E Page 17 of 64...
Yellow The LED is on when the battery is charging. NOTE The battery can only be charged if the emergency stop switch is not actuated! Operating manual SENTA PUR L V2.5 E Page 18 of 64...
Operating elements and their function 7.3 24V battery unit The SENTA PUR L combination bathing lift is equipped with a 24V-battery system. Proceed as described in chapter 13.5 to remove the battery. 7.4 External charging unit/wall charger The external charging unit (wall charging unit) is a switch-mode charger and is supplied ready assembled (on a mounting rail).
Battery compartment folded down Activating the emergency lowering system: The SENTA PUR L combination bathing lift is equipped with a manual emergency lowering system. Through the hole located in the end cap of the carrier frame, the seat or the stretcher can be manually lowered using the 6 mm Allen wrench, which is included in delivery.
Insert a ballpoint or a similar object into the holes to actuate the buttons. The seat is raised or lowered. Note: The buttons of the North-American version of the control unit are accessible without ballpoint. Control unit button (North America) Operating manual SENTA PUR L V2.5 E Page 21 of 64...
The emergency stop switch can also be used to reduce discharging of the battery in case of intermediate storage. By pressing the emergency stop switch, you can lock the SENTA PUR L combination bathing lift, thus making any unauthorized use of the device more difficult.
➢ Check whether the castors run free. 8.2 Using the SENTA PUR L as sitting lift The SENTA PUR L (sitting lift) is equipped with adjustable safety armrests, which offer the patient a safe grip. The safety armrests can be simply folded backward or forward. The special, easy-to- clean paddings offer the patient optimal hold.
Operation 8.3 Using the SENTA PUR L as stretcher lift The SENTA stretcher lift is divided into three parts, so that the lift can be positioned on the desired side of the patient’s bed. As soon as the lift is positioned at the patient’s bed, both wings (left-hand side and right-hand side) are folded up or down, so that the patient’s back and legs can be smoothly positioned onto the stretcher.
The safety armrests must not be used to support the patient when standing up from the lift. 8.5 Disassembly/assembly of the adjustable wings The SENTA PUR L combination bathing lift can optionally be equipped with adjustable wings. These wings can be assembled or disassembled individually.
Please check that the locking bolt is correctly latched and that the wing cannot be inadvertently slid from the bolts. 8.6 Disassembly/assembly of the side rails The SENTA PUR L combination bathing lift can optionally be equipped with side rails. Operating manual SENTA PUR L V2.5 E...
The side rail must be ordered directly ex-works. Integrating a side rail after delivery is not possible! 8.6.1 Disassembly of the side rails Open the lock Lock Opened lock Operating manual SENTA PUR L V2.5 E Page 27 of 64...
Page 28
Operation Pull the closing flap forward Closing flap unlocked flap Remove the side rail by pulling upwards. Removed side rail Re-assemble in reversed order. Operating manual SENTA PUR L V2.5 E Page 28 of 64...
Now, you can remove the safety armrest by pulling. The safety armrest is assembled in reverse order. WARNING: Prior to raising or lowering the SENTA, the arm must be folded in front position! Operating manual SENTA PUR L V2.5 E Page 29 of 64...
Operation 8.8 Operating the SENTA PUR L The seat of the SENTA PUR L combination bathing lift is raised or lowered by means of the handset, which is included in the delivery. • Pushing the button raises the seat. • Pushing the button lowers the seat.
3. If necessary, lower the side rails of the patient’s bed 4. Turn the patient on his/her side. 5. Position the reclining surface or the seat of the SENTA PUR L over the mattress. 6. Engage the brakes of the SENTA PUR L to lock the castors.
8. Raise the SENTA and transport the patient/resident. Caution: Please observe the sitting direction of the patient/resident! Sliding direction False Correct CAUTION: Do not lift the patient/resident higher than necessary. Operating manual SENTA PUR L V2.5 E Page 32 of 64...
2. Raise the bathing lift so that the safety distance between the seat or stretcher of the lift and the tub edge is approx. 10 cm. When setting the height, you must ensure that there is sufficient lateral distance between the SENTA PUR L and the bath tub.
The SL scale is destined to measure forces and weights. It is a non-calibrated scale. The following units can be set: N, kN, g, kg, t or lb. With the SENTA PUR L, you can weigh persons up to 150 kg at the most.
• Preparing the weighing procedure: ➢ Position the patient/resident onto the SENTA PUR L combination bathing lift. ➢ Make sure that the patient/resident is sitting or lying completely on the combination bathing lift and that the weighing procedure is not influenced by the patient/resident partly resting on e.g.
You must always check whether the settings of the particular case meet the legal provisions. The BEKA Hospitec EDI 03 is a high-precision digital weight indicator, based upon the latest sigma-delta A/D-technology. This provides for an accurate and fast weight display.
IP X5. 8.12.9 Waste disposal Remove the batteries prior to the device’s disposal. Used batteries must be disposed of in accordance with the environmental regulations. Operating manual SENTA PUR L V2.5 E Page 37 of 64...
HOLD button. The HOLD symbol will appear on the screen. If you press the HOLD button once more, the normal weight display will be reactivated. Operating manual SENTA PUR L V2.5 E Page 38 of 64...
<HOLD>. Press <LIVE WT> for 2 seconds to switch between the weighing of persons and the normal weight display. The display then briefly shows NORMAL or LIVE.WT. 2 seconds Operating manual SENTA PUR L V2.5 E Page 39 of 64...
A <ZERO>, <TARE> or <PRINT> (STABLE) Repeat the procedure when command cannot be executed in the (ERROR) the scale is stable. absence of a standstill. Operating manual SENTA PUR L V2.5 E Page 40 of 64...
Weighing cell signal too high for this setting or will become too high in case of full load. (HIGH) (ZERO) Zero point below -2mV/V (LO) (ZERO) Zero point above +2mV/V (HIGH) Operating manual SENTA PUR L V2.5 E Page 41 of 64...
• E0012 (E0010+E0002) indicates that both the voltage supply is too high and the temperature too high. • E0C00 (E0800+E0400) indicates that the factory settings are lost and the EEPROM is defect. Operating manual SENTA PUR L V2.5 E Page 42 of 64...
2700 mAh. This is sufficient for approx. 24 hours of weighing.) 4. The charging process is not automatically interrupted; therefore, you should terminate the charging process after the specified time. Operating manual SENTA PUR L V2.5 E Page 43 of 64...
9 Cleaning/disinfection 9.1 Cleaning the SENTA PUR L bathing lift Clean the SENTA PUR L combination bathing lift with a soft, lint-free cloth. For thorough cleaning, use a cloth moistened with a mild soap solution. Clean the product every day and prior to each use.
Repairs may be carried out only either by BEKA Hospitec or by companies authorized to this effect by BEKA Hospitec. If the battery is discharged, recharge it as soon as possible to extend the lifetime. Batteries stored in the warehouse/stock must be recharged every 6 months (a possible deep discharge may destroy the battery).
For an environmentally-sound disposal, the company BEKA Hospitec GmbH will provide more information in its capacity of manufacturer. Please clean and disinfect the SENTA PUR L combination bathing lift prior to its disposal as well. Operating manual SENTA PUR L V2.5 E...
Inform the after-sales service. produces unusual noises. The combination bathing lift is Inform the after-sales service. damaged. The “Service” indication is lit. The annual safety check must be carried out. Operating manual SENTA PUR L V2.5 E Page 47 of 64...
Page 48
(red) is on. When your SENTA PUR L combination bathing lift does not function properly and you cannot eliminate the error by means of the remedies listed in paragraph 12, please contact the customer service of your dealer either the manufacturer.
Caution: The thread-locking fluid must dry at least 3 hours before the device can be loaded. Should you use thread lock fluid from another manufacturer, the drying times specified by this manufacturer must be observed! Re-assemble in reversed order! Operating manual SENTA PUR L V2.5 E Page 49 of 64...
Caution: The thread-locking fluid must dry at least 3 hours before the device can be loaded. Should you use thread lock fluid from another manufacturer, the drying times specified by this manufacturer must be observed! Re-assemble in reversed order! Operating manual SENTA PUR L V2.5 E Page 50 of 64...
Image 9: Remove the 4 Unscrew the retaining screws of magnet manually the fixation of the after loosening. control box. Image 11: Remove the fixation of the control box. Operating manual SENTA PUR L V2.5 E Page 51 of 64...
Image 4: The image shows the removed Image 3: battery. Pull the battery up When replacing the to remove it. battery, please make sure that the release lever engages audibly. Operating manual SENTA PUR L V2.5 E Page 52 of 64...
- 40 °C to 70 °C and raising aid): - Temperature range (battery): - 15 °C to 40 °C - Relative humidity: 10% to 80%, non-condensing 500 – 1100 hPA - Atmospheric pressure: Operating manual SENTA PUR L V2.5 E Page 53 of 64...
Appendix 14.4 Spare parts and accessories of the SENTA PUR L Spare part n° Description K9201150 Handset K9300270 Double castors 125 mm rear, with parking brake K9200350 Double castors 100 mm front K9200541 Control box CBJ 921070600 Spare battery 24 V...
Guidance and manufacturer’s declaration - electromagnetic immunity (Table 201) The SENTA PUR L has been designed for use in the hereafter listed ELECTROMAGNETIC ENVIRONMENTS. The customer or the user of the SENTA PUR L must ensure that the appliance is used in such environment.
Page 58
Guidance and manufacturer’s declaration - electromagnetic immunity (Table 202) The SENTA PUR L has been designed for use in the hereafter listed ELECTROMAGNETIC ENVIRONMENTS. The customer or the user of the SENTA PUR L must ensure that the appliance is used in such environment.
Page 59
SENTA PUR L is to be used, exceeds the applicable HF compliance level, special care should be taken that a normal operation of the SENTA PUR L can be guaranteed. In case anomalies are identified, additional measures could be required, such as a different alignment or a change of the location of the SENTA PUR L.
Page 60
Recommended distance between portable and mobile communications equipment and the SENTA PUR L. (Table 206) The SENTA PUR L is intended for use in an electromagnetic environment with controlled HF interferences. The customer or the user of the SENTA PUR L can avoid electromagnetic...
According to §13 of the Medical Device Directive, you are compelled to keep a journal for this device. You can use this journal as template. Journal Device: SENTA PUR L combination bathing lift Manufacturer: BEKA Hospitec GmbH, Am Rübenmorgen 3, 35582 Wetzlar Serial number: _____________________________________________ Date of purchase: _____________________________________________ Site: _____________________________________________...
Page 62
Appendix Periodic inspection, repair, DGUV-3, safety check, etc. Type of Date Result Measure Signature: inspection Operating manual SENTA PUR L V2.5 E Page 62 of 64...
Need help?
Do you have a question about the SENTA PUR L and is the answer not in the manual?
Questions and answers